Induction and binding of Cd, Cu, and Zn to metallothionein in carp (Cyprinus carpio) using HPLC-ICP-TOFMS

被引:46
|
作者
Van Campenhout, K
Infante, HG
Adams, F
Blust, R
机构
[1] Univ Antwerp, Dept Biol, Ecophysiol Biochem & Toxicol Grp, B-2020 Antwerp, Belgium
[2] Univ Instelling Antwerp, Dept Chem, B-2610 Antwerp, Belgium
关键词
Cyprinus carpio; metallothionein; copper; zinc; cadmium; HPLC ICP-TOFMS;
D O I
10.1093/toxsci/kfh149
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The binding of Cd, Cu, and Zn to metallothionein in carp was studied under control and acute Cd exposure scenarios. Carp were exposed to different Cd concentrations for 96 h. Total (Cu, Cd, Zn)-MT levels were determined by the cadmium thiomolybdate saturation assay. Total tissue and cytosolic Cd, Cu, and Zn concentrations were determined by ICP-MS. The cytosolic metal speciation was determined by high pressure liquid chromatography (size-exclusion [SE] in combination with anion exchange [AE]) directly coupled to an inductively coupled plasma time of flight mass spectrometer (ICP-TOFMS). This coupled technique allows the chromatographic separation and online determination of the metals associated to the protein fractions separated. Very strong differences in the tissue compartmentalization and cytosolic speciation of the metals were observed. For example, over 30% of cytosolic zinc was bound to MT in liver while this was only 2% in the kidneys although total cytosolic levels were considerably higher. Induction of metallothionein during cadmium exposure was also tissue specific, displaying different response patterns in gills, liver, and kidney. Cadmium accumulated much stronger in liver and kidney compared to the gills and the latter also showed much lower MT levels. The renal MT-induction was more sensitive to Cd exposure than the hepatic MT induction since a significant increase of Cd-MT and total MT levels occurred at lower tissue Cd concentrations in the kidney in comparison to the liver, except for the highest Cd exposure level where a drastic 10-fold increase in hepatic Cd-MT was observed. At this Cd exposure level also an apparent spill over of zinc to the high molecular weight fraction was observed in the kidneys.
引用
收藏
页码:276 / 287
页数:12
相关论文
共 48 条
  • [41] An ICP-MS procedure to determine Cd, Co, Cu, Ni, Pb and Zn in oceanic waters using in-line flow-injection with solid-phase extraction for preconcentration
    O'Sullivan, Jeanette E.
    Watson, Roslyn J.
    Butler, Edward C. V.
    TALANTA, 2013, 115 : 999 - 1010
  • [42] Chemical interactions of mercury species and some transition and noble metals towards metallothionein (Zn7MT-2) evaluated using SEC/ICP-MS, RP-HPLC/ESI-MS and MALDI-TOF-MS
    Xu, Ming
    Yang, Limin
    Wang, Qiuquan
    METALLOMICS, 2013, 5 (07) : 855 - 860
  • [43] Determination of Trace Metal (Mn, Fe, Ni, Cu, Zn, Co, Cd and Pb) Concentrations in Seawater Using Single Quadrupole ICP-MS: A Comparison between Offline and Online Preconcentration Setups
    Samanta, Saumik
    Cloete, Ryan
    Loock, Jean
    Rossouw, Riana
    Roychoudhury, Alakendra N.
    MINERALS, 2021, 11 (11)
  • [44] Characterization of the metal status of natively purified alpha-synuclein from human blood, brain tissue, or recombinant sources using size exclusion ICP-MS reveals no significant binding of Cu, Fe or Zn
    Lothian, Amber
    Lago, Larissa
    Mukherjee, Soumya
    Connor, Andrea R.
    Fowler, Chris
    McLean, Catriona A.
    Horne, Malcolm
    Masters, Colin L.
    Cappai, Roberto
    Roberts, Blaine R.
    METALLOMICS, 2019, 11 (01) : 128 - 140
  • [45] Analysis of Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb in seawater using the Nobias-chelate PA1 resin and magnetic sector inductively coupled plasma mass spectrometry (ICP-MS)
    Biller, Dondra V.
    Bruland, Kenneth W.
    MARINE CHEMISTRY, 2012, 130 : 12 - 20
  • [46] Dispersive micro-solid phase extraction method using newly prepared poly(methyl methacrylate) grafted agarose combined with ICP-MS for the simultaneous determination of Cd, Ni, Cu and Zn in vegetable and natural water samples
    Pourmand, Neda
    Sanagi, Mohd Marsin
    Abu Naim, Ahmedy
    Ibrahim, Wan Aini Wan
    Baig, Umair
    ANALYTICAL METHODS, 2015, 7 (07) : 3215 - 3223
  • [47] Solid phase extraction of trace amounts of Ag, Cd, Cu, and Zn in environmental samples using magnetic nanoparticles coated by 3-(trimethoxysilyl)-1-propantiol and modified with 2-amino-5-mercapto-1,3,4-thiadiazole and their determination by ICP-OES
    Mashhadizadeh, Mohammad Hossein
    Karami, Zahra
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 190 (1-3) : 1023 - 1029
  • [48] Pressurized Flow Solubilization System Using Electromagnetic Induction Heating Technique for Simultaneous Determination of Inorganic Elements (Ba, Ca, Cd, Cu, Fe, Mg, Mn, Na, Pb, Sr, Zn) in Sonicate Slurries of Biological Materials by Microwave Induced Plasma Optical Emission Spectrometry (MIP-OES)
    Matusiewicz, Henryk
    Slachcinski, Mariusz
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (03) : 584 - 590