Reducing MRI RF-induced heating for the external fixation using capacitive structures

被引:2
|
作者
Zheng, Jianfeng [1 ]
Yang, Rui [1 ]
Wang, Qingyan [1 ]
Guo, Ran [1 ]
Xu, Jian [2 ]
Shou, Xingxian [2 ]
Kainz, Wolfgang [3 ]
Chen, Ji [1 ]
机构
[1] Univ Houston, Dept Elect & Comp Engn, Houston, TX 77204 USA
[2] UIH Amer Inc, Houston, TX 77054 USA
[3] US FDA, Div Biomed Phys, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 15期
关键词
RF-induced heating; magnetic resonance imaging; external fixation device; insulating material; DEEP BRAIN-STIMULATION; IMPLANT; SAFETY;
D O I
10.1088/1361-6560/ab9706
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a generic method to reduce the radiofrequency (RF) induced heating of external fixation devices during the magnetic resonance imaging (MRI) procedure. A simplified equivalent circuit model was developed to illustrate the interaction between the external fixation device and the MRI RF field. Carefully designed mechanical structures, which utilize capacitive reactance from the circuit model, were applied to the external fixation device to mitigate the coupling between the external fixation device and the MRI RF field for RF-induced heating reduction. Both numerical and experimental studies were performed to demonstrate the validity of the circuit model and the effectiveness of the proposed method. By adding capacitive structures in both the clamp-pin and rod-clamp joints, the peak specific absorption rate averaged in 1 gram (SAR(1g)) near the pin tips were reduced from 760.4 W kg(-1)to 12.0 W kg(-1)at 1.5 T and 391.5 W kg(-1)to 25.2 W kg(-1)at 3 T from numerical simulations. Experimental results showed that RF-induced heating was reduced from 7.85 degrees C to 1.01 degrees C at 1.5 T and from 16.70 degrees C to 0.32 degrees C at 3 T for the external fixation device studied here. The carefully designed capacitive structures can be used to detune the coupling between the external fixation device and the MRI fields to reduce the RF-induced heating in the human body for both 1.5 T and 3 T MRI systems. However, as RF-induced heating is very device and design specific all devices must be thoroughly tested based on its final design.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Numerical evaluation of RF-induced heating for gap and pitch variation of helical stent under MRI
    Ji, Xiaohe
    Zheng, Jianfeng
    Chen, Ji
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2017, : 1017 - 1018
  • [32] Evaluating Effect of Calibration Factor for Lead Computational Model to Assess MRI RF-Induced Heating
    Kozlov, Mikhail
    Kainz, W.
    2018 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2018, : 891 - 892
  • [33] Impact of RF Shimming on RF-Induced Heating Near Implantable Medical Electrodes in a 3T MRI Coil
    Zeng, Qi
    Wang, Qingyan
    Kainz, Wolfgang
    Chen, Ji
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2020, 62 (01) : 52 - 64
  • [34] Study on the searching strategies of assessing the MRI RF-induced heating for an implantable plate and screw system
    Ji, Xiaohe
    Xia, Meiqi
    Zheng, Jianfeng
    Chen, Ji
    Kainz, Wolfgang
    2018 JOINT IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND 2018 IEEE ASIA-PACIFIC SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC/APEMC), 2018, : 932 - 935
  • [35] Effects of Strain Relief Loop on MRI RF-Induced Heating of Active Implantable Medical Devices
    Akter, Mir Khadiza
    Guo, Ran
    Islam, Md Zahidul
    Zheng, Jianfeng
    Chen, Ji
    PROCEEDINGS OF THE 2022 IEEE TEXAS SYMPOSIUM ON WIRELESS AND MICROWAVE CIRCUITS AND SYSTEMS (WMCS), 2022,
  • [36] Numerical Model for Estimating RF-Induced Heating on a Pacemaker Implant During MRI: Experimental Validation
    Mattei, Eugenio
    Calcagnini, Giovanni
    Censi, Federica
    Triventi, Michele
    Bartolini, Pietro
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (08) : 2045 - 2052
  • [37] Numerical study on MRI RF-induced heating for the trauma screw implanted in three human models
    Xia, Meiqi
    Zheng, Jianfeng
    Chen, Ji
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND SIGNAL & POWER INTEGRITY VIRTUAL SYMPOSIUM(IEEE EMC+SIPI), 2020, : 257 - 260
  • [38] RF-Induced Heating Comparison Between in-vivo and in-phantom for 1.5T MRI
    Guo, Ran
    Zheng, Jianfeng
    Chen, Ji
    Kainz, Wolfgang
    2016 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC), 2016, : 121 - 125
  • [39] Effect of Treatment for Abandoned DBS Leads on RF-Induced Heating during 1.5T MRI
    Guo, Ran
    Hu, Wei
    Zheng, Jianfeng
    Ballard, Caleb J.
    Herrera, Daniel
    Chen, Ji
    2022 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS 2022), 2022, : 791 - 793
  • [40] RF-induced ankle heating in a rhesus monkey at 100 MHz
    Olsen, RG
    Van Matre, BJ
    Lords, JL
    ELECTRICITY AND MAGNETISM IN BIOLOGY AND MEDICINE, 1999, : 307 - 310