Numerical Model for Estimating RF-Induced Heating on a Pacemaker Implant During MRI: Experimental Validation

被引:32
|
作者
Mattei, Eugenio [1 ]
Calcagnini, Giovanni [1 ]
Censi, Federica [1 ]
Triventi, Michele [1 ]
Bartolini, Pietro [1 ]
机构
[1] Italian Natl Inst Hlth, Dept Technol & Hlth, I-00161 Rome, Italy
关键词
MRI; pacemaker (PM); RF fields; SAR; IN-VITRO; CARDIAC-PACEMAKERS; FIELDS; COILS; SAFETY; VIVO;
D O I
10.1109/TBME.2010.2043102
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
MRI may cause tissue heating in patients implanted with pacemakers (PMs) or cardioverters/defibrillators. As a consequence, these patients are often preventatively excluded from MRI investigations. The issue has been studied for several years now, in order to identify the mechanisms involved in heat generation, and define safety conditions by which MRI may be extended to patients with active implants. In this sense, numerical studies not only widen the range of experimental measurements, but also model a realistic patient's anatomy on which it is possible to study individually the impact of the many parameters involved. In order to obtain reliable results, however, each and every numerical analysis needs to be validated by experimental evidence. Aim of this paper was to design and validate through experimental measurements, an accurate numerical model, which was able to reproduce the thermal effects induced by a birdcage coil on human tissues containing a metal implant, specifically, a PM. The model was then used to compare the right versus left pectoral implantation of a PM, in terms of power deposited at the lead tip. This numerical model may also be used as reference for validating simpler models in terms of computational effort.
引用
收藏
页码:2045 / 2052
页数:8
相关论文
共 50 条
  • [1] Spatial distribution of RF-induced E-fields and implant heating in MRI
    Nordbeck, Peter
    Fidler, Florian
    Weiss, Ingo
    Warmuth, Marcus
    Friedrich, Michael T.
    Ehses, Philipp
    Geistert, Wolfgang
    Ritter, Oliver
    Jakob, Peter M.
    Ladd, Mark E.
    Quick, Harald H.
    Bauer, Wolfgang R.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) : 312 - 319
  • [2] An RF-induced voltage sensor for investigating pacemaker safety in MRI
    Thérèse Barbier
    Roberto Piumatti
    Bertrand Hecker
    Freddy Odille
    Jacques Felblinger
    Cédric Pasquier
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 539 - 549
  • [3] An RF-induced voltage sensor for investigating pacemaker safety in MRI
    Barbier, Therese
    Piumatti, Roberto
    Hecker, Bertrand
    Odille, Freddy
    Felblinger, Jacques
    Pasquier, Cedric
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (06) : 539 - 549
  • [4] MRI safety: RF-induced heating near straight wires
    Park, SM
    Kamondetdacha, R
    Amjad, A
    Nyenhuis, JA
    IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (10) : 4197 - 4199
  • [5] A technique for the reduction of RF-induced heating of active implantable medical devices during MRI
    Wang, Yu
    Zheng, Jianfeng
    Guo, Ran
    Wang, Qingyan
    Kainz, Wolfgang
    Long, Stuart
    Chen, Ji
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 349 - 364
  • [6] Numerical evaluation of RF-induced heating for gap and pitch variation of helical stent under MRI
    Ji, Xiaohe
    Zheng, Jianfeng
    Chen, Ji
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2017, : 1017 - 1018
  • [7] Numerical study on MRI RF-induced heating for the trauma screw implanted in three human models
    Xia, Meiqi
    Zheng, Jianfeng
    Chen, Ji
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND SIGNAL & POWER INTEGRITY VIRTUAL SYMPOSIUM(IEEE EMC+SIPI), 2020, : 257 - 260
  • [8] Data-Driven Experimental Evaluation Method for the Safety Assessment of Implants With Respect to RF-Induced Heating During MRI
    Yao, Aiping
    Zastrow, Earl
    Kuster, Niels
    RADIO SCIENCE, 2018, 53 (06) : 700 - 709
  • [9] Evaluating Effect of Calibration Factor for Lead Computational Model to Assess MRI RF-Induced Heating
    Kozlov, Mikhail
    Kainz, W.
    2018 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2018, : 891 - 892
  • [10] Safety of active catheters in MRI: Termination impedance versus RF-induced heating
    Oezen, Ali Caglar
    Lottner, Thomas
    Bock, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1412 - 1423