Aortic valve replacement with small-sized disc prostheses (Medtronic Hall)

被引:0
|
作者
Brazao, AJ [1 ]
Prieto, D [1 ]
de Oliveira, JF [1 ]
Eugenio, L [1 ]
Antunes, MJ [1 ]
机构
[1] Univ Hosp, Dept Cardiothorac Surg, P-3049 Coimbra, Portugal
来源
JOURNAL OF HEART VALVE DISEASE | 1999年 / 8卷 / 06期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Several studies have demonstrated a worse performance of small prostheses in the narrow aortic root. However, modern low-profile mechanical prostheses have improved hemodynamic performance, are easy to implant, and have been used increasingly in elderly patients, where narrow roots are most frequently observed. We describe our experience in patients with aortic annuli >21 mm with the use of Medtronic Hall prostheses. Methods: Between April 1988 and December 1997, a total of 332 patients (218 females, 114 males; mean age 59.3 +/- 9.8 years (range: 29-75 years) received Medtronic Hall size 20 (n = 140), 21 (n = 96) or 22 (n = 96) prostheses. The mean body surface area was 1.59 +/- 0.12 m(2) (range: 1.27-2.01 m(2)); 140 patients were in NYHA functional classes III/IV. There were no significant differences in clinical characteristics of patients in the three prosthesis-size groups. Results: The mean preoperative systolic left ventricular/aorta gradient was 64.5 +/- 24.8 mmHg (no significant inter-group difference). After cardiopulmonary bypass, peak gradients through the aortic prostheses were 13.9 +/- 8.0 mmHg in size 20 valves, 14.0 +/- 8.1 mmHg in size 21, and 10.1 +/- 8.9 mmHg in size 22. Four patients died in hospital (mortality rate 1.2%); there were no significant inter-group differences in hospital morbidity. Follow up was complete for 97% of the patients (mean 4.3 years; range: 1-11 years). The late mortality rate was 9.3% (n = 31; 2.56% per pt-yr); of these patients, 20 (14.3%) had size 20 prostheses, seven (7.3%) size 21, and four (4.2%) size 22 (p = 0.01). Fourteen patients (4.2%) died from cardiac causes, and six (1.8%) from prosthesis-related causes. Preoperative older age and aortic regurgitation were the only independent predictors of late mortality. Eight patients had systemic thromboembolic events (0.66% per pt-yr), two had prosthetic thrombosis (0.17% per pt-yr) and five had hemorrhagic episodes (0.41% per pt-yr). Seven patients had prosthetic valve endocarditis (0.58% per pt-yr). Among survivors, 97% are currently in NYHA class I/II. Conclusions: The small (size 20, 21 and 22) Medtronic Hall prostheses have good hemodynamic performance and are an excellent option as valve substitutes in patients with narrow aortic roots.
引用
收藏
页码:680 / 686
页数:7
相关论文
共 50 条
  • [31] CENTRAL FLOW TILTING DISC VALVE FOR AORTIC VALVE REPLACEMENT
    BJORK, VO
    THORAX, 1970, 25 (04) : 439 - &
  • [32] Structural Valve Deterioration After Aortic Valve Replacement with Medtronic Freestyle Stentless Porcine Aortic Root Bioprostheses
    Nishida, Hidefumi
    Komiya, Tatsuhiko
    Sakaguchi, Genichi
    Shimamoto, Takeshi
    JOURNAL OF CARDIAC SURGERY, 2014, 29 (01) : 22 - 25
  • [33] Are small-sized mechanical valves adequate for patients with small aortic roots?
    Pandey, Pratik
    Saha, Apu
    Jha, Neeraj Kumar
    Rao, Yashaskar Manjunatha
    Das, Debasis
    Das, Mrinalendu
    Chatterjee, Debika
    Narayan, Pradeep
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2022, 30 (09): : 992 - 1000
  • [34] Conventional Biological versus Sutureless Aortic Valve Prostheses in Combined Aortic and Mitral Valve Replacement
    Zubarevich, Alina
    Szczechowicz, Marcin
    Arjomandi Rad, Arian
    Amanov, Lukman
    Ruhparwar, Arjang
    Weymann, Alexander
    LIFE-BASEL, 2023, 13 (03):
  • [35] ANTIAGGREGATORY THERAPY COMPARED WITH ANTICOAGULATORY THERAPY AFTER AORTIC-VALVE REPLACEMENT WITH HALL-KASTER PROSTHESES
    VOLKMER, I
    HELLSTERN, P
    LECOUTRE, C
    STAPENHORST, K
    THORACIC AND CARDIOVASCULAR SURGEON, 1983, 31 : 16 - 16
  • [36] Endovascular Repair for Type A Aortic Dissection After Transcatheter Aortic Valve Replacement With a Medtronic CoreValve
    Berfield, Kathleen K. S.
    Sweet, Matthew P.
    McCabe, James M.
    Reisman, Mark
    Mackensen, G. Burkhard
    Mokadam, Nahush A.
    Dean, Larry S.
    Smith, Jason W.
    ANNALS OF THORACIC SURGERY, 2015, 100 (04): : 1444 - 1446
  • [37] Aortic valve replacement in small patients
    Hisata, Y.
    Yokose, S.
    Hazama, S.
    Matsumaru, I.
    Eishi, K.
    ASIAN JOURNAL OF SURGERY, 2018, 41 (06) : 578 - 584
  • [38] Bioprostheses with atrial fibrillation and mechanical prostheses in aortic valve replacement
    Jamieson, WRE
    Miyagishima, RT
    Henderson, C
    Germann, E
    THORACIC AND CARDIOVASCULAR SURGEON, 2005, 53 (03): : 150 - 153
  • [39] Downstream turbulence and high intensity transient signals (HITS) following aortic valve replacement with Medtronic Hall or St. Jude Medical valve substitutes
    Kleine, P
    Perthel, M
    Hasenkam, JM
    Nygaard, H
    Hansen, SB
    Laas, J
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (01) : 20 - 24
  • [40] Redo aortic valve replacement for an incorrectly sized rapid deployment valve
    Zhu, Yuanjia
    Wang, Hanjay
    Kim, Joon Bum
    Woo, Y. Joseph
    JTCVS TECHNIQUES, 2024, 23 : 18 - 20