Introduction: Bone density can interfere with fluoroscopy-guided tumor tracking in radiotherapy. To improve markerless tumor tracking accuracy, we developed a dual energy subtraction (DES) mechanical image mask to use with a single x-ray exposure. Methods: The DES mask consists of 2-mm-thick stainless-steel with 128 pairs of slits (0.388 mm width and openings), designed to match the dynamic flat panel detector (DFPD) pixel size. This was set on the front of the DFPD. This results in a DFPD image with one containing the exposed pixels and one containing the masked pixels. The masked pixel columns were interpolated from adjacent pixels and a subtraction image was generated from the interpolated images to make a bone suppression (BS) image. A chest phantom was set on the commercially available moving table (CIRS DYNAMIC PLATFORM 008PL) and DFPD images were acquired. A reference BS image was generated by double-exposure DES with and without a 2-mm-thick stainless-steel plate. Image quality and markerless tumor tracking accuracy were then evaluated. Results: The DES mask decreased most of the visible bone densities from the chest phantom image acquired with a single exposure for a peak-signal-to-noise-ratio/structural similarity index measure (PSNR/SSIM) of 25.3 db/ 0.685). The tracking positional error, originally 12.6 mm, was improved to 0.2 mm. Conclusions: The DES mask can aid in BS image on fluoroscopic imaging and may be useful in markerless tumor tracking.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 50 条
  • [41] Can the Real-time Tumor-tracking Radiotherapy Give the Planned Dose to the Tumor? DVH Analysis Based on Measured Real-time Tracking Data
    Ishikawa, M.
    Sutherland, K. L.
    Bengua, G.
    Suzuki, R.
    Miyamoto, N.
    Katoh, N.
    Shimizu, S.
    Onimaru, R.
    Aoyama, H.
    Shirato, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S590 - S591
  • [42] Low-cost soft-copy display accuracy in the detection of pulmonary nodules by single-exposure dual-energy subtraction: Comparison with hard-copy viewing
    Kido, S
    Kuriyama, K
    Hosomi, N
    Inoue, E
    Kuroda, C
    Horai, T
    JOURNAL OF DIGITAL IMAGING, 2000, 13 (01) : 33 - 37
  • [43] Effect of different noise reduction techniques and template matching parameters on markerless tumor tracking using dual-energy imaging
    Kaur, Mandeep
    Wagstaff, Peter
    Mostafavi, Hassan
    Lehmann, Mathias
    Morf, Daniel
    Zhu, Liangjia
    Kang, Hyejoo
    Walczak, Michal
    Harkenrider, Matthew M.
    Roeske, John C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [44] Real-time markerless tumour tracking with patient-specific deep learning using a personalised data generation strategy: proof of concept by phantom study
    Takahashi, Wataru
    Oshikawa, Shota
    Mori, Shinichiro
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1109):
  • [45] Portable Single-Exposure Dual-Energy X-ray Detector for Improved Point-of-Care Diagnostic Imaging
    Karim, Karim S.
    Ii, Steven Tilley
    MILITARY MEDICINE, 2023, 188 : 84 - 91
  • [46] Regression model-based real-time markerless tumor tracking with fluoroscopic images for hepatocellular carcinoma
    Hirai, Ryusuke
    Sakata, Yukinobu
    Tanizawa, Akiyuki
    Mori, Shinichiro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 70 : 196 - 205
  • [47] Stereoscopic and monoscopic real-time x-ray image guidance for markerless lung tumor tracking
    McLure, Zakary
    Sattarivand, Mike
    MEDICAL PHYSICS, 2024, 51 (08) : 5826 - 5827
  • [48] Real-Time Markerless Tumor Tracking with MV Imaging and a Dynamic Multi-Leaf Collimator (DMLC)
    Rottmann, J.
    Keall, P.
    Yue, Y.
    Berbeco, R.
    MEDICAL PHYSICS, 2012, 39 (06) : 3890 - 3890
  • [49] Real-Time Dual-Energy Pulmonary Angiography On An Interventional C-Arm
    Nikolau, E.
    Wagner, M.
    Schafer, S.
    Speidel, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E322 - E322
  • [50] Physical aspects of a real-time tumor-tracking system for gated radiotherapy
    Shirato, H
    Shimizu, S
    Kunieda, T
    Kitamura, K
    van Herk, M
    Kagei, K
    Nishioka, T
    Hashimoto, S
    Fujita, K
    Aoyama, H
    Tsuchiya, K
    Kudo, K
    Miyasaka, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04): : 1187 - 1195