摘要
Introduction: Bone density can interfere with fluoroscopy-guided tumor tracking in radiotherapy. To improve markerless tumor tracking accuracy, we developed a dual energy subtraction (DES) mechanical image mask to use with a single x-ray exposure. Methods: The DES mask consists of 2-mm-thick stainless-steel with 128 pairs of slits (0.388 mm width and openings), designed to match the dynamic flat panel detector (DFPD) pixel size. This was set on the front of the DFPD. This results in a DFPD image with one containing the exposed pixels and one containing the masked pixels. The masked pixel columns were interpolated from adjacent pixels and a subtraction image was generated from the interpolated images to make a bone suppression (BS) image. A chest phantom was set on the commercially available moving table (CIRS DYNAMIC PLATFORM 008PL) and DFPD images were acquired. A reference BS image was generated by double-exposure DES with and without a 2-mm-thick stainless-steel plate. Image quality and markerless tumor tracking accuracy were then evaluated. Results: The DES mask decreased most of the visible bone densities from the chest phantom image acquired with a single exposure for a peak-signal-to-noise-ratio/structural similarity index measure (PSNR/SSIM) of 25.3 db/ 0.685). The tracking positional error, originally 12.6 mm, was improved to 0.2 mm. Conclusions: The DES mask can aid in BS image on fluoroscopic imaging and may be useful in markerless tumor tracking.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 50 条
  • [31] Detection of lung tumor movement in real-time tumor-tracking radiotherapy
    Shimizu, S
    Shirato, H
    Ogura, S
    Akita-Dosaka, H
    Kitamura, K
    Nishioka, T
    Kagei, K
    Nishimura, M
    Miyasaka, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (02): : 304 - 310
  • [32] Dual Modality Verification for Respiratory Gating Using New Real-Time Tumor Tracking Radiotherapy System
    Shiinoki, T.
    Kawamura, S.
    Koike, M.
    Yuasa, Y.
    Uehara, T.
    Fujimoto, K.
    Hanazawa, H.
    Shibuya, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3649 - 3649
  • [33] Experimental optimization of single-exposure dual-energy angiography with photon-counting x-ray detectors
    Aubert, Sarah
    Tanguay, Jesse
    MEDICAL PHYSICS, 2023, 50 (02) : 763 - 777
  • [34] Real-time diagnosis of intracerebral hemorrhage by generating dual-energy CT from single-energy CT
    Jiang, Caiwen
    Wang, Tianyu
    Pan, Yongsheng
    Ding, Zhongxiang
    Shen, Dinggang
    MEDICAL IMAGE ANALYSIS, 2024, 95
  • [35] Real-time markerless lung tumor tracking in fluoroscopic video: Handling overlapping of projected structures
    Teske, Hendrik
    Mercea, Paul
    Schwarz, Michael
    Nicolay, Nils H.
    Sterzing, Florian
    Bendl, Rolf
    MEDICAL PHYSICS, 2015, 42 (05) : 2540 - 2549
  • [36] A REAL-TIME DUAL-ENERGY PROBE FOR TISSUE CHARACTERIZATION DURING FLUOROSCOPY
    SPELLER, RD
    BABAHAMED, T
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (03): : 379 - 388
  • [37] Real-time tumor-tracking and four-dimensional radiotherapy
    Shirato, H. (shirato@med.hokudai.ac.jp), 1600, Institute of Electronics Information and Communication Eng., Annex 3F, 5-22, Shibakoen 3 chome, Minato-ku, Tokyo, 105-0011, Japan (96):
  • [38] A Kernel-Based Method for Real-Time Markerless Tumor Tracking in Fluoroscopic Image Sequence
    Zhang, Xiaoyong
    Homma, Noriyasu
    Takai, Yoshihiro
    Narita, Yuichiro
    Ichiji, Kei
    Abe, Makoto
    Sugita, Norihiro
    Yoshizawa, Makoto
    2013 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2013, : 828 - 832
  • [39] Low-cost soft-copy display accuracy in the detection of pulmonary nodules by single-exposure dual-energy subtraction: Comparison with hard-copy viewing
    Shoji Kido
    Keiko Kuriyama
    Naohiro Hosomi
    Etsuo Inoue
    Chikazumi Kuroda
    Takeshi Horai
    Journal of Digital Imaging, 2000, 13 : 33 - 37
  • [40] Single-exposure dual-energy subtraction computed radiography of the chest for detection of low-contrast simulated nodules: Comparison of hard- and soft-copy images
    Kido, S
    Kuriyama, K
    Kuroda, C
    Horai, T
    RADIOLOGY, 1998, 209P : 320 - 320