Portable Single-Exposure Dual-Energy X-ray Detector for Improved Point-of-Care Diagnostic Imaging

被引:3
|
作者
Karim, Karim S. [1 ,2 ]
Ii, Steven Tilley [2 ]
机构
[1] Univ Waterloo, Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
[2] KA Imaging, Waterloo, ON N2L 5Z4, Canada
关键词
DIGITAL RADIOGRAPHY; CHEST RADIOGRAPHY; SUBTRACTION;
D O I
10.1093/milmed/usad034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Dual-energy subtraction (DES) imaging is well known to reduce anatomical noise and enable material classification. The current approaches to DES imaging have trade-offs, such as motion artifacts, low sensitivity because of losses in a mid-filter, and lack of portability. Recently, a portable triple-layer flat-panel detector (FPD) was proposed for use in single-shot DES imaging that can provide improved sensitivity and removal of motion artifacts in a point-of-care setting. The purpose of this study is to evaluate the feasibility of such a detector. Various image quality metrics and clinical images are provided. Materials and Methods: An FDA-cleared single-exposure DES FPD consisting of three stacked sensors was used for all measurements. This detector generates three images per exposure: A digital radiography (DR) image, i.e., as would be produced with a conventional detector, and two DES images, bone and soft tissue. To evaluate DR image quality, detective quantum efficiency (DQE) and modulation transfer function were measured for multiple radiation quality beams. Digital radiography and DES images obtained from this FPD were evaluated in previously reported fixed and portable clinical studies. Digital radiography and DES images from case studies are presented for qualitative assessment. Results: Modulation transfer function and DQE were measured across multiple radiation quality beams for the DR image. The DES images showed good tissue separation and uniformity with no visible motion or alignment artifacts. The DES images, when read in conjunction with the DR image, resulted in increased reader confidence and revealed abnormalities or details that were sometimes overlooked in the DR image. Conclusions: The proposed panel produces high-quality DR images as indicated by the DQE and modulation transfer function. The DES images have been shown to improve sensitivity in clinical applications and increase reader confidence. This detector can enable DES in portable or otherwise difficult applications, opening new doors for improved patient care.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 50 条
  • [1] Contrast and quantum noise in single-exposure dual-energy thoracic imaging with photon-counting x-ray detectors
    Dhari, Jeffrey
    Tanguay, Jesse
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (19):
  • [2] Experimental optimization of single-exposure dual-energy angiography with photon-counting x-ray detectors
    Aubert, Sarah
    Tanguay, Jesse
    MEDICAL PHYSICS, 2023, 50 (02) : 763 - 777
  • [3] Single-exposure dual-energy-subtraction X-ray imaging using a synchrotron source
    Carnibella, R. P.
    Fouras, A.
    Kitchen, M. J.
    JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 954 - 959
  • [4] SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY - IMPROVED DETECTION AND PROCESSING
    ERGUN, DL
    MISTRETTA, CA
    BROWN, DE
    BYSTRIANYK, RT
    SZE, WK
    KELCZ, F
    NAIDICH, DP
    RADIOLOGY, 1990, 174 (01) : 243 - 249
  • [5] SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY
    STEWART, BK
    HUANG, HK
    MEDICAL PHYSICS, 1990, 17 (05) : 866 - 875
  • [6] Linear modeling of single-shot dual-energy x-ray imaging using a sandwich detector
    Kim, J.
    Kim, D. W.
    Kim, S. H.
    Yun, S.
    Youn, H.
    Jeon, H.
    Kim, H. K.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [7] Single-shot dual-energy x-ray imaging with a flat-panel sandwich detector for preclinical imaging
    Han, Jong Chul
    Kim, Ho Kyung
    Kim, Dong Woon
    Yun, Seungman
    Youn, Hanbean
    Kam, Soohwa
    Tanguay, Jesse
    Cunningham, Ian A.
    CURRENT APPLIED PHYSICS, 2014, 14 (12) : 1734 - 1742
  • [8] Comparing performances of a CdTe X-ray spectroscopic detector and an X-ray dual-energy sandwich detector
    Gorecki, A.
    Brambilla, A.
    Moulin, V.
    Gaborieau, E.
    Radisson, P.
    Verger, L.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [9] CZT detector for dual-energy x-ray absorptiometry (DEXA)
    Wear, J
    Buchholz, M
    Payne, R
    Gorsuch, D
    Bisek, J
    Ergun, D
    Grosholz, J
    Falk, R
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 175 - 188
  • [10] Single-exposure X-ray phase imaging microscopy with a grating interferometer
    Wolf, Andreas
    Akstaller, Bernhard
    Cipiccia, Silvia
    Flenner, Silja
    Hagemann, Johannes
    Ludwig, Veronika
    Meyer, Pascal
    Schropp, Andreas
    Schuster, Max
    Seifert, Maria
    Weule, Mareike
    Michel, Thilo
    Anton, Gisela
    Funk, Stefan
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 : 794 - 806