SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY - IMPROVED DETECTION AND PROCESSING

被引:104
|
作者
ERGUN, DL
MISTRETTA, CA
BROWN, DE
BYSTRIANYK, RT
SZE, WK
KELCZ, F
NAIDICH, DP
机构
[1] UNIV WISCONSIN,MADISON,WI 53706
[2] NYU,NEW YORK,NY 10003
关键词
radiography; computer-assisted; digital; technology; screens and films; subtraction; dual-energy;
D O I
10.1148/radiology.174.1.2294555
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent reports have emphasized the potential for dual-energy computed radiographic applications. An improved method for single-exposure material-selective imaging with a photostimulable phosphor computed radiography system was investigated. The essential elements of the technique are (a) prefiltration with gadolinium, which divides the incident broad-beam x-ray spectrum into low-energy and high-energy peaks; (b) a cassette consisting of four photostimulable phosphor plates that record images of increasing mean energies, with a computed energy separation of 23 keV from the front to the rear plate; (c) spatially dependent scatter and beam-hardening corrections; and (d) a noise-reduction algorithm based on noise correlations between bone-selective and soft-tissue-selective dual-energy images. These elements result in improved material cancellation and signal-to-noise ratio throughout the image.
引用
收藏
页码:243 / 249
页数:7
相关论文
共 50 条
  • [1] SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY
    STEWART, BK
    HUANG, HK
    MEDICAL PHYSICS, 1990, 17 (05) : 866 - 875
  • [2] Improvement of detection in computed radiography by new single-exposure dual-energy subtraction
    Ito, Wataru
    Shimura, Kazuo
    Nakajima, Nobuyoshi
    Ishida, Masamitsu
    Kato, Hisatoyo
    Fuji Film research & development, 1993, (38): : 48 - 58
  • [3] NEW SINGLE-EXPOSURE DUAL-ENERGY IMAGES AT CHEST RADIOGRAPHY - IMPROVED DETECTION OF PULMONARY NODULES
    KIDO, S
    IKEZOE, J
    KOZUKA, T
    ITO, W
    SHIMURA, K
    KATO, H
    RADIOLOGY, 1992, 185 : 148 - 149
  • [4] Computerized detection of pulmonary nodules by single-exposure dual-energy computed radiography of the chest (part 1)
    Kido, S
    Nakamura, H
    Ito, W
    Shimura, K
    Kato, H
    EUROPEAN JOURNAL OF RADIOLOGY, 2002, 44 (03) : 198 - 204
  • [5] Detection of lung cancer using single-exposure dual-energy subtraction chest radiography
    Ide K.
    Mogami H.
    Murakami T.
    Yasuhara Y.
    Miyagawa M.
    Mochizuki T.
    Radiation Medicine, 2007, 25 (5): : 195 - 201
  • [6] SINGLE-EXPOSURE DUAL-ENERGY CHEST IMAGES WITH COMPUTED RADIOGRAPHY - EVALUATION WITH SIMULATED PULMONARY NODULES
    KIDO, S
    IKEZOE, JP
    NAITO, H
    TAMURA, S
    KOZUKA, T
    ITO, W
    SHIMURA, K
    KATO, H
    INVESTIGATIVE RADIOLOGY, 1993, 28 (06) : 482 - 487
  • [7] COMPUTERIZED DETECTION OF PULMONARY NODULES IN SINGLE-EXPOSURE DUAL-ENERGY SUBTRACTION DIGITAL CHEST RADIOGRAPHY
    KIDO, S
    IKEZOE, J
    TAMURA, S
    YAMAMOTO, H
    NAKAMURA, H
    RADIOLOGY, 1995, 197 : 426 - 426
  • [8] Single-exposure dual-energy subtraction chest radiography: Detection of pulmonary nodules and masses in clinical practice
    Szucs-Farkas, Zsolt
    Patak, Michael A.
    Yuksel-Hatz, Seyran
    Ruder, Thomas
    Vock, Peter
    EUROPEAN RADIOLOGY, 2008, 18 (01) : 24 - 31
  • [9] Single-exposure dual-energy subtraction chest radiography: Detection of pulmonary nodules and masses in clinical practice
    Zsolt Szucs-Farkas
    Michael A. Patak
    Seyran Yuksel-Hatz
    Thomas Ruder
    Peter Vock
    European Radiology, 2008, 18 : 24 - 31
  • [10] SINGLE EXPOSURE DUAL-ENERGY SUBTRACTION RADIOGRAPHY OF THE UPPER AIRWAYS USING COMPUTED RADIOGRAPHY
    ODAGIRI, K
    FUJIWARA, T
    ANDOH, K
    KINNO, Y
    MATSUURA, H
    TSUKUDA, M
    ACTA RADIOLOGICA, 1992, 33 (03) : 281 - 283