SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY - IMPROVED DETECTION AND PROCESSING

被引:104
|
作者
ERGUN, DL
MISTRETTA, CA
BROWN, DE
BYSTRIANYK, RT
SZE, WK
KELCZ, F
NAIDICH, DP
机构
[1] UNIV WISCONSIN,MADISON,WI 53706
[2] NYU,NEW YORK,NY 10003
关键词
radiography; computer-assisted; digital; technology; screens and films; subtraction; dual-energy;
D O I
10.1148/radiology.174.1.2294555
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent reports have emphasized the potential for dual-energy computed radiographic applications. An improved method for single-exposure material-selective imaging with a photostimulable phosphor computed radiography system was investigated. The essential elements of the technique are (a) prefiltration with gadolinium, which divides the incident broad-beam x-ray spectrum into low-energy and high-energy peaks; (b) a cassette consisting of four photostimulable phosphor plates that record images of increasing mean energies, with a computed energy separation of 23 keV from the front to the rear plate; (c) spatially dependent scatter and beam-hardening corrections; and (d) a noise-reduction algorithm based on noise correlations between bone-selective and soft-tissue-selective dual-energy images. These elements result in improved material cancellation and signal-to-noise ratio throughout the image.
引用
收藏
页码:243 / 249
页数:7
相关论文
共 50 条
  • [21] Single exposure dual energy subtraction computed radiography of the chest for the assessment of nodule detection
    Hartman, TE
    Aughenbaugh, GL
    Harms, GF
    Sykes, AG
    Weaver, AL
    Hodge, D
    RADIOLOGY, 1998, 209P : 410 - 410
  • [22] CONVENTIONAL CHEST RADIOGRAPHY VS DUAL-ENERGY COMPUTED RADIOGRAPHY IN THE DETECTION AND CHARACTERIZATION OF PULMONARY NODULES
    KELCZ, F
    ZINK, FE
    PEPPLER, WW
    KRUGER, DG
    ERGUN, DL
    MISTRETTA, CA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (02) : 271 - 278
  • [23] Portable Single-Exposure Dual-Energy X-ray Detector for Improved Point-of-Care Diagnostic Imaging
    Karim, Karim S.
    Ii, Steven Tilley
    MILITARY MEDICINE, 2023, 188 : 84 - 91
  • [24] CLINICAL-EVALUATION OF PULMONARY NODULES WITH SINGLE-EXPOSURE DUAL-ENERGY SUBTRACTION CHEST RADIOGRAPHY WITH AN ITERATIVE NOISE-REDUCTION ALGORITHM
    KIDO, S
    IKEZOE, J
    NAITO, H
    ARISAWA, J
    TAMURA, S
    KOZUKA, T
    ITO, W
    SHIMURA, K
    KATO, H
    RADIOLOGY, 1995, 194 (02) : 407 - 412
  • [25] Improved detection of small lung cancers with dual-energy subtraction chest radiography
    Li, Feng
    Engelmann, Roger
    Doi, Kunio
    MacMahon, Heber
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) : 886 - 891
  • [26] Dual-energy radiography
    Hartman, TE
    SEMINARS IN ROENTGENOLOGY, 1997, 32 (01) : 45 - 49
  • [27] Active energy selective image detector for dual-energy computed radiography
    Alvarez, RE
    MEDICAL PHYSICS, 1996, 23 (10) : 1739 - 1748
  • [28] Fast voltage switching detector for dual-energy computed radiography
    Alvarez, RE
    Seibert, JA
    RADIOLOGY, 1996, 201 : 504 - 504
  • [29] Experimental optimization of single-exposure dual-energy angiography with photon-counting x-ray detectors
    Aubert, Sarah
    Tanguay, Jesse
    MEDICAL PHYSICS, 2023, 50 (02) : 763 - 777
  • [30] A METHOD FOR SINGLE EXPOSURE DUAL ENERGY RADIOGRAPHY
    ZANANIRI, FAF
    SPELLER, RD
    MACHIN, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (02): : 168 - 168