Single-exposure dual-energy subtraction chest radiography: Detection of pulmonary nodules and masses in clinical practice

被引:37
|
作者
Szucs-Farkas, Zsolt [1 ]
Patak, Michael A. [1 ]
Yuksel-Hatz, Seyran [1 ]
Ruder, Thomas [1 ]
Vock, Peter [1 ]
机构
[1] Univ Hosp Bern, Dept Intervent & Diagnost Radiol, CH-3010 Bern, Switzerland
关键词
dual-energy scanned projection radiography; pulmonary coin lesion; pulmonary neoplasms;
D O I
10.1007/s00330-007-0758-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this retrospective study was to evaluate the impact of energy subtraction (ES) chest radiography on the detection of pulmonary nodules and masses in daily routine. Seventy-seven patients and 25 healthy subjects were examined with a single exposure digital radiography system. Five blinded readers evaluated first the non-subtracted PA and lateral chest radiographs alone and then together with the subtracted PA soft tissue images. The size, location and number of lung nodules or masses were registered with the confidence level. CT was used as standard of reference. For the 200 total lesions, a sensitivity of 33.5-52.5% was found at non-subtracted and a sensitivity of 43.5-58.5% at energy-subtracted radiography, corresponding to a significant improvement in four of five readers (p<0.05). However, in three of five readers the rate of false positives was higher with ES. With ES, sensitivity, but not the area under the alternative free-response receiver operating characteristics (AFROC) curve, showed a good correlation with reader experience (R=0.90, p=0.026). In four of five readers, the diagnostic confidence improved with ES (p=0.0036). We conclude that single-exposure digital ES chest radiography improves detection of most pulmonary nodules and masses, but identification of nodules <1 cm and false-positive findings remain a problem.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [1] Single-exposure dual-energy subtraction chest radiography: Detection of pulmonary nodules and masses in clinical practice
    Zsolt Szucs-Farkas
    Michael A. Patak
    Seyran Yuksel-Hatz
    Thomas Ruder
    Peter Vock
    European Radiology, 2008, 18 : 24 - 31
  • [2] COMPUTERIZED DETECTION OF PULMONARY NODULES IN SINGLE-EXPOSURE DUAL-ENERGY SUBTRACTION DIGITAL CHEST RADIOGRAPHY
    KIDO, S
    IKEZOE, J
    TAMURA, S
    YAMAMOTO, H
    NAKAMURA, H
    RADIOLOGY, 1995, 197 : 426 - 426
  • [3] NEW SINGLE-EXPOSURE DUAL-ENERGY IMAGES AT CHEST RADIOGRAPHY - IMPROVED DETECTION OF PULMONARY NODULES
    KIDO, S
    IKEZOE, J
    KOZUKA, T
    ITO, W
    SHIMURA, K
    KATO, H
    RADIOLOGY, 1992, 185 : 148 - 149
  • [4] Detection of lung cancer using single-exposure dual-energy subtraction chest radiography
    Ide K.
    Mogami H.
    Murakami T.
    Yasuhara Y.
    Miyagawa M.
    Mochizuki T.
    Radiation Medicine, 2007, 25 (5): : 195 - 201
  • [5] Computerized detection of pulmonary nodules by single-exposure dual-energy computed radiography of the chest (part 1)
    Kido, S
    Nakamura, H
    Ito, W
    Shimura, K
    Kato, H
    EUROPEAN JOURNAL OF RADIOLOGY, 2002, 44 (03) : 198 - 204
  • [6] CLINICAL-EVALUATION OF PULMONARY NODULES WITH SINGLE-EXPOSURE DUAL-ENERGY SUBTRACTION CHEST RADIOGRAPHY WITH AN ITERATIVE NOISE-REDUCTION ALGORITHM
    KIDO, S
    IKEZOE, J
    NAITO, H
    ARISAWA, J
    TAMURA, S
    KOZUKA, T
    ITO, W
    SHIMURA, K
    KATO, H
    RADIOLOGY, 1995, 194 (02) : 407 - 412
  • [7] SINGLE-EXPOSURE DUAL-ENERGY CHEST IMAGES WITH COMPUTED RADIOGRAPHY - EVALUATION WITH SIMULATED PULMONARY NODULES
    KIDO, S
    IKEZOE, JP
    NAITO, H
    TAMURA, S
    KOZUKA, T
    ITO, W
    SHIMURA, K
    KATO, H
    INVESTIGATIVE RADIOLOGY, 1993, 28 (06) : 482 - 487
  • [8] Improvement of detection in computed radiography by new single-exposure dual-energy subtraction
    Ito, Wataru
    Shimura, Kazuo
    Nakajima, Nobuyoshi
    Ishida, Masamitsu
    Kato, Hisatoyo
    Fuji Film research & development, 1993, (38): : 48 - 58
  • [9] SINGLE-EXPOSURE DUAL ENERGY DIGITAL RADIOGRAPHY IN THE DETECTION OF PULMONARY NODULES AND CALCIFICATIONS
    OESTMANN, JW
    GREENE, R
    RHEA, JT
    ROSENTHAL, H
    KOENKER, RM
    TILLOTSON, CL
    PEARSEN, KD
    HILL, JW
    VELAJ, RH
    INVESTIGATIVE RADIOLOGY, 1989, 24 (07) : 517 - 521
  • [10] Comparison of Chest Dual-energy Subtraction Digital Tomosynthesis and Dual-energy Subtraction Radiography for Detection of Pulmonary Nodules: Initial Evaluations in Human Clinical Cases
    Gomi, Tsutomu
    Nozaki, Miwako
    Takeda, Tohoru
    Umeda, Tokuo
    Takahashi, Kazutoshi
    Nakajima, Masahiro
    ACADEMIC RADIOLOGY, 2013, 20 (11) : 1357 - 1363