摘要
Introduction: Bone density can interfere with fluoroscopy-guided tumor tracking in radiotherapy. To improve markerless tumor tracking accuracy, we developed a dual energy subtraction (DES) mechanical image mask to use with a single x-ray exposure. Methods: The DES mask consists of 2-mm-thick stainless-steel with 128 pairs of slits (0.388 mm width and openings), designed to match the dynamic flat panel detector (DFPD) pixel size. This was set on the front of the DFPD. This results in a DFPD image with one containing the exposed pixels and one containing the masked pixels. The masked pixel columns were interpolated from adjacent pixels and a subtraction image was generated from the interpolated images to make a bone suppression (BS) image. A chest phantom was set on the commercially available moving table (CIRS DYNAMIC PLATFORM 008PL) and DFPD images were acquired. A reference BS image was generated by double-exposure DES with and without a 2-mm-thick stainless-steel plate. Image quality and markerless tumor tracking accuracy were then evaluated. Results: The DES mask decreased most of the visible bone densities from the chest phantom image acquired with a single exposure for a peak-signal-to-noise-ratio/structural similarity index measure (PSNR/SSIM) of 25.3 db/ 0.685). The tracking positional error, originally 12.6 mm, was improved to 0.2 mm. Conclusions: The DES mask can aid in BS image on fluoroscopic imaging and may be useful in markerless tumor tracking.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 50 条
  • [1] Improvement of detection in computed radiography by new single-exposure dual-energy subtraction
    Ito, Wataru
    Shimura, Kazuo
    Nakajima, Nobuyoshi
    Ishida, Masamitsu
    Kato, Hisatoyo
    Fuji Film research & development, 1993, (38): : 48 - 58
  • [2] Dual-Energy Real-Time Stereoscopic X-Ray Image Guidance for Markerless Lung Tumor Tracking
    Peacock, C.
    Sattarivand, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [3] SINGLE-EXPOSURE DUAL-ENERGY COMPUTED RADIOGRAPHY
    STEWART, BK
    HUANG, HK
    MEDICAL PHYSICS, 1990, 17 (05) : 866 - 875
  • [4] Detection of lung cancer using single-exposure dual-energy subtraction chest radiography
    Ide K.
    Mogami H.
    Murakami T.
    Yasuhara Y.
    Miyagawa M.
    Mochizuki T.
    Radiation Medicine, 2007, 25 (5): : 195 - 201
  • [5] Feasibility Study of Markerless Tracking Using Dual Energy Fluoroscopic Images for Real-Time Tumor-Tracking Radiotherapy System
    Shiinoki, T.
    Sawada, A.
    Uehara, T.
    Yuasa, Y.
    Koike, M.
    Kawamura, S.
    Shibuya, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3650 - 3650
  • [6] COMPUTERIZED DETECTION OF PULMONARY NODULES IN SINGLE-EXPOSURE DUAL-ENERGY SUBTRACTION DIGITAL CHEST RADIOGRAPHY
    KIDO, S
    IKEZOE, J
    TAMURA, S
    YAMAMOTO, H
    NAKAMURA, H
    RADIOLOGY, 1995, 197 : 426 - 426
  • [7] Single-exposure dual-energy subtraction chest radiography: Detection of pulmonary nodules and masses in clinical practice
    Szucs-Farkas, Zsolt
    Patak, Michael A.
    Yuksel-Hatz, Seyran
    Ruder, Thomas
    Vock, Peter
    EUROPEAN RADIOLOGY, 2008, 18 (01) : 24 - 31
  • [8] Single-exposure dual-energy subtraction chest radiography: Detection of pulmonary nodules and masses in clinical practice
    Zsolt Szucs-Farkas
    Michael A. Patak
    Seyran Yuksel-Hatz
    Thomas Ruder
    Peter Vock
    European Radiology, 2008, 18 : 24 - 31
  • [9] Adaptive weighted log subtraction based on neural networks for markerless tumor tracking using dual-energy fluoroscopy
    Haytmyradov, Maksat
    Mostafavi, Hassan
    Cassetta, Roberto
    Patel, Rakesh
    Surucu, Murat
    Zhu, Liangjia
    Roeske, John C.
    MEDICAL PHYSICS, 2020, 47 (02) : 672 - 680
  • [10] Feasibility of markerless tumor tracking by sequential dual-energy fluoroscopy on a clinical tumor tracking system
    Dhont, J.
    Poels, K.
    Verellen, D.
    Tournel, K.
    Gevaert, T.
    Steenbeke, F.
    De Ridder, M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 591 - 594