Evaluation of the Diesse Cube 30 touch erythrocyte sedimentation method in comparison with Alifax test 1 and the manual Westergren gold standard method

被引:10
|
作者
Pieri, Massimo [1 ]
Pignalosa, Stefano [1 ]
Perrone, Marco Alfonso [2 ]
Russo, Carmelo [1 ]
Noce, Gianluca [1 ]
Perrone, Andrea [3 ]
Terrinoni, Alessandro [1 ]
Massoud, Renato [1 ]
Bernardini, Sergio [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Expt Med & Surg, Div Clin Biochem & Clin Mol Biol, Viale Montpellier 1, I-00133 Rome, Italy
[2] Univ Roma Tor Vergata, Dept Expt Med, Div Cardiol, Rome, Italy
[3] Univ Roma Tor Vergata, Dept Enterprise Engn, Rome, Italy
关键词
Erythrocyte sedimentation rate; Westergren method; ESR; evaluation; comparison;
D O I
10.1080/00365513.2021.1881996
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The erythrocyte sedimentation rate (ESR) is a traditional nonspecific laboratory test used for the assessment of inflammation. Even if its usefulness is nowadays being largely debated, it is still considered a valuable laboratory test in selected clinical conditions, such as rheumatoid diseases, orthopedic infections and Hodgkin's lymphoma, and it can be used for the infectious, inflammatory, malignancies, and autoimmune diseases follow-up. The introduction of new methodologies on semi-automated and automated analyzers started about four decades ago and opened a new era of ESR analysis characterized by shorter assay time, use of (EDTA) undiluted blood, that increases sample stability and allows using a single sample for also other hematologic tests, and greater safety for laboratory personnel. In this context, the aim of this study was to evaluate the performances of new device Diesse Cube 30 touch, comparing it with Alifax Test 1 and with the gold standard Westergren method. The new Diesse Cube 30 touch for determination of the ESR shows a good correlation with the manual Westergren gold standard method in a shorter time, and in a standardized way, since all the phases of the test are automatized. The Diesse Cube 30 touch respect the manual gold standard method, displayed a small bias to confirm that the new automated test system tended to have a small bias for ESR values (mean positive bias +0.2 mm/h). The findings of the present study show that the Diesse Cube 30 touch Westergren-based method can be a valid alternative in laboratory analysis for the determination of ESR.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 46 条
  • [21] COMPARATIVE ANALYSIS OF TEST-1 ERYTHROCYTE SEDIMENTATION RATE ANALYZER VERSUS WESTERGREN METHOD IN EVALUATING NORMAL AND ANEMIC BLOOD SAMPLES
    Prompetchara, Eakachai
    Chaiwong, Kwanlada
    Ketloy, Chutitorn
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2024, 46 : 82 - 82
  • [22] Comparison of LSRB in children measured by the Westergren method and by the Test-1 analyzer
    Papakonstantinou, E.
    Yfantis, E.
    Georgoutsou, P.
    Lavda, A.
    Skourbouti, A.
    Chaniotaki, S.
    Chontrothanasi, A.
    Koutoulas, G.
    Manti, Ch.
    ARCHIVES OF HELLENIC MEDICINE, 2010, 27 (01): : 72 - 77
  • [23] Erythrocyte Sedimentation Rate Measurements by TEST 1 Better Reflect Inflammation Than Do Those by the Westergren Method in Patients With Malignancy, Autoimmune Disease, or Infection
    Cha, Choong-Hwan
    Park, Chan-Jeoung
    Cha, Young Joo
    Kim, Hyun Kyung
    Kim, Duck Hee
    Honghoon
    Bae, Jae Hoon
    Jung, Jae-Seol
    Jang, Seongsoo
    Chi, Hyun-Sook
    Lee, Dong Soon
    Cho, Han-Ik
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2009, 131 (02) : 189 - 194
  • [24] ERYTHROCYTE SEDIMENTATION RATE MEASUREMENT BY TEST-1 REFLECTS INFLAMMATION BETTER THAN THOSE BY WESTERGREN METHOD IN PATIENTS WITH MALIGNANCY, AUTOIMMUNE DISEASE AND INFECTION
    Cha, C. H.
    Park, C. J.
    Cha, Y. J.
    Kim, H. K.
    Kim, D. H.
    Hong, H.
    Bae, J. H.
    Jung, J. S.
    Chi, H. S.
    Lee, D. S.
    Cho, H. I.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2008, 93 : 476 - 476
  • [25] A COMPARISON OF THE WINTROBE, THE WESTERGREN AND THE ZSR ERYTHROCYTE SEDIMENTATION-RATE (ELECTRON-SPIN-RESONANCE) METHODS TO A CANDIDATE REFERENCE METHOD
    MOSELEY, DL
    BULL, BS
    CLINICAL AND LABORATORY HAEMATOLOGY, 1982, 4 (02): : 169 - 178
  • [26] The TEST 1 automated system - A new method for measuring the erythrocyte sedimentation rate
    Plebani, M
    De Toni, S
    Sanzari, MC
    Bernardi, D
    Stockreiter, E
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 110 (03) : 334 - 340
  • [27] Comparison of erythrocyte sedimentation rate measurement between Westergren method and automated method among patients attending Jigjiga University Sheik Hassen Yabare Referral Hospital, Jigjiga, Ethiopia
    Walle, Muluken
    Alemayehu, Ermiyas
    Tesfaye, Addisu
    Arkew, Mesay
    Asmerom, Haftu
    Agidew, Melaku Mekonnen
    Getu, Fasil
    FRONTIERS IN MEDICINE, 2024, 11
  • [28] Length of erythrocyte sedimentation rate (ESR) adjusted for the hematocrit:: Reference values for the TEST 1™ method
    Giavarina, D
    Capuzzo, S
    Pizzolato, U
    Soffiati, G
    CLINICAL LABORATORY, 2006, 52 (5-6) : 241 - 245
  • [29] Evaluation and Comparison of Automatic Brain Segmentation Methods Based On the Gold Standard Method
    Zamanpour S.A.
    Ganji Z.
    Bigham B.
    Zemorshidi F.
    Zare H.
    Iranian Journal of Medical Physics, 2023, 20 (04) : 233 - 245
  • [30] Accuracy Evaluation of Diagnostic Test without Gold Standard Based on Latent Class Method
    Jin Hui
    Liu Pei
    PROCEEDINGS OF THE 5TH INTERNATIONAL ACADEMIC CONFERENCE ON ENVIRONMENTAL AND OCCUPATIONAL MEDICINE, 2010, : 256 - 259