Central and Midperipheral Corneal Thickness Measured with Scheimpflug Imaging and Optical Coherence Tomography

被引:13
|
作者
Huang, Jinhai [1 ,2 ,3 ]
Ding, Xixia [1 ,2 ,3 ]
Savini, Giacomo [1 ,2 ,4 ]
Jiang, Zhengxuan [5 ]
Pan, Chao [1 ,2 ]
Hua, Yanjun [1 ,2 ]
Wu, Fan [1 ,2 ]
Feng, Yifan [1 ,2 ]
Yu, Ye [1 ,2 ]
Wang, Qinmei [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Sch Optometry & Ophthalmol, Wenzhou, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Hosp Eye, Wenzhou, Zhejiang, Peoples R China
[3] Minist Hlth PR China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[4] Studio Oculist DAzeglio, Bologna, Italy
[5] Anhui Med Univ, Affiliated Hosp 2, Hefei, Anhui, Peoples R China
来源
PLOS ONE | 2014年 / 9卷 / 05期
关键词
ANTERIOR SEGMENT MEASUREMENTS; PACHYMETRY MEASUREMENTS; ULTRASONIC PACHYMETRY; DIURNAL-VARIATION; CONTACT-LENS; REPEATABILITY; REPRODUCIBILITY; AGREEMENT; GALILEI; INTRAOBSERVER;
D O I
10.1371/journal.pone.0098316
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To compare corneal thickness measurements using Pentacam (Oculus, Germany), Sirius (CSO, Italy), Galilei (Ziemer, Switzerland), and RTVue-100 OCT (Optovue Inc., USA). Methods: Sixty-six eyes of 66 healthy volunteers were enrolled. Three consecutive measurements were performed with each device. The mean value of the three measurements was used for subsequent analysis. Central corneal thickness (CCT), thinnest corneal thickness (TCT), and midperipheral corneal thickness (MPCT; measured at superior, inferior, nasal, and temporal locations with a distance of 1 mm (CT2mm) or 2.5 mm (CT5mm) from the corneal apex) were analyzed. Differences and agreement between measurements were assessed using the repeated-measures analysis of variance (ANOVA) and Bland-Altman analyses, respectively. Results: Statistically significant differences (p<0.001) among the four devices were revealed in CCT, TCT and CT2mm measurements. The CCT, TCT, and CT2mm values were ranked from the thickest to the thinnest as follows: Galilei>Sirius>Pentacam>RTVue OCT. For these measurements, agreement between measurements by Sirius and Pentacam was good, whereas Galilei overestimated and RTVue underestimated corneal thickness compared to Sirius and Pentacam. As regards CT5mm measurements, Pentacam provided the largest values, whereas RTVue OCT yielded the smallest values. Agreement of the CT5mm measurements was good between the Pentacam, Sirius, moderate between Galilei and the other two Scheimpflug systems, and poor between the RTVue OCT and the remaining devices. Conclusions: The Pentacam and Sirius can be used interchangeably for CCT measurements, while the Galilei and RTVue systematically over- and underestimate CCT, respectively. The three Scheimpflug cameras, but not the RTVue, may be used interchangeably for MPCT measurements.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The evaluation of corneal tomography using swept-source optical coherence tomography and Scheimpflug imaging in healthy and ectasia eyes
    Herber, Robert
    Pillunat, Lutz E.
    Raiskup, Frederik
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [32] Agreement of Central Corneal Thickness Measurements between Scheimpflug Photography and Optical Low-Coherence Reflectometry in Children
    Hashemi, Hassan
    Nabovati, Payam
    Khabazkhoob, Mehdi
    Emamian, Mohammad Hassan
    Yekta, Abbasali
    Fotouhi, Akbar
    [J]. SEMINARS IN OPHTHALMOLOGY, 2020, 35 (04) : 252 - 256
  • [33] Comparison of Central Corneal Thickness Measured by Standard Ultrasound Pachymetry, Corneal Topography, Tono-Pachymetry and Anterior Segment Optical Coherence Tomography
    Gonzalez-Perez, Javier
    Queiruga Pineiro, Juan
    Sanchez Garcia, Angelx
    Gonzalez Meijome, Jose Manuel
    [J]. CURRENT EYE RESEARCH, 2018, 43 (07) : 866 - 872
  • [34] Assessment of central corneal thickness in normal, keratoconus, and post-laser in situ keratomileusis eyes using Scheimpflug imaging, spectral domain optical coherence tomography, and ultrasound pachymetry
    Grewal, Dilraj S.
    Brar, Gagandeep S.
    Grewal, Satinder P. S.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06): : 954 - 964
  • [35] Comparison of Stratus Optical Coherence Tomography and Ultrasound Biomicroscopy for Measurement of the Central Corneal Thickness
    Turk, Adem
    Erdol, Hidayet
    Karaguzel, Hande
    Akyol, Nurettin
    [J]. TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2010, 30 (03): : 962 - 969
  • [36] Comparison of Oculus Pentacam and Stratus Optical Coherence Tomography for Measurement of Central Corneal Thickness
    Ceylan, Osman Melih
    Turk, Adem
    Erdurman, Cuneyt
    Mumcuoglu, Tarkan
    Erdem, Uzeyir
    Gokce, Gokcen
    Dagli, Selim
    [J]. CORNEA, 2011, 30 (06) : 670 - 674
  • [37] Scheimpflug Tomography versus Optical Coherence Tomography to detect subclinical corneal edema in Fuchs Endothelial Corneal Dystrophy
    Augustin, Victor A.
    Koeppe, Maximilian K.
    Son, Hyeck-Soo
    Meis, Jan
    Yildirim, Timur M.
    Khoramnia, Ramin
    Auffarth, Gerd U.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [38] Comparison of corneal thickness measured with optical coherence tomography, ultrasonic pachymetry, and a scanning slit method
    Thomas, Joseph
    Wang, Jianhua
    Rollins, Andrew M.
    Sturm, Julie
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (07) : 671 - 678
  • [39] Comparison between central corneal thickness measurements by ultrasound pachymetry and optical coherence tomography
    Leung, Dexter Y. L.
    Lam, Douglas K. T.
    Yeung, Barry Y. M.
    Lam, Dennis S. C.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (08): : 751 - 754
  • [40] Comparison of Scheimpflug Corneal Tomography and Anterior Segment Optical Coherence Tomography Measurements in Corneal Cystinosis: A Case Series
    Vercauteren, Leonie
    Consejo, Alejandra
    De Vries, Meindert Jan
    Krolo, Iva
    Koppen, Carina
    Dhubhghaill, Sorcha Ni
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (07): : 321 - 328