Central and Midperipheral Corneal Thickness Measured with Scheimpflug Imaging and Optical Coherence Tomography

被引:13
|
作者
Huang, Jinhai [1 ,2 ,3 ]
Ding, Xixia [1 ,2 ,3 ]
Savini, Giacomo [1 ,2 ,4 ]
Jiang, Zhengxuan [5 ]
Pan, Chao [1 ,2 ]
Hua, Yanjun [1 ,2 ]
Wu, Fan [1 ,2 ]
Feng, Yifan [1 ,2 ]
Yu, Ye [1 ,2 ]
Wang, Qinmei [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Sch Optometry & Ophthalmol, Wenzhou, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Hosp Eye, Wenzhou, Zhejiang, Peoples R China
[3] Minist Hlth PR China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[4] Studio Oculist DAzeglio, Bologna, Italy
[5] Anhui Med Univ, Affiliated Hosp 2, Hefei, Anhui, Peoples R China
来源
PLOS ONE | 2014年 / 9卷 / 05期
关键词
ANTERIOR SEGMENT MEASUREMENTS; PACHYMETRY MEASUREMENTS; ULTRASONIC PACHYMETRY; DIURNAL-VARIATION; CONTACT-LENS; REPEATABILITY; REPRODUCIBILITY; AGREEMENT; GALILEI; INTRAOBSERVER;
D O I
10.1371/journal.pone.0098316
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To compare corneal thickness measurements using Pentacam (Oculus, Germany), Sirius (CSO, Italy), Galilei (Ziemer, Switzerland), and RTVue-100 OCT (Optovue Inc., USA). Methods: Sixty-six eyes of 66 healthy volunteers were enrolled. Three consecutive measurements were performed with each device. The mean value of the three measurements was used for subsequent analysis. Central corneal thickness (CCT), thinnest corneal thickness (TCT), and midperipheral corneal thickness (MPCT; measured at superior, inferior, nasal, and temporal locations with a distance of 1 mm (CT2mm) or 2.5 mm (CT5mm) from the corneal apex) were analyzed. Differences and agreement between measurements were assessed using the repeated-measures analysis of variance (ANOVA) and Bland-Altman analyses, respectively. Results: Statistically significant differences (p<0.001) among the four devices were revealed in CCT, TCT and CT2mm measurements. The CCT, TCT, and CT2mm values were ranked from the thickest to the thinnest as follows: Galilei>Sirius>Pentacam>RTVue OCT. For these measurements, agreement between measurements by Sirius and Pentacam was good, whereas Galilei overestimated and RTVue underestimated corneal thickness compared to Sirius and Pentacam. As regards CT5mm measurements, Pentacam provided the largest values, whereas RTVue OCT yielded the smallest values. Agreement of the CT5mm measurements was good between the Pentacam, Sirius, moderate between Galilei and the other two Scheimpflug systems, and poor between the RTVue OCT and the remaining devices. Conclusions: The Pentacam and Sirius can be used interchangeably for CCT measurements, while the Galilei and RTVue systematically over- and underestimate CCT, respectively. The three Scheimpflug cameras, but not the RTVue, may be used interchangeably for MPCT measurements.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Distribution of corneal thickness measured using optical coherence tomography in South African young adults
    Rampersad, Nishanee
    Hansraj, Rekha
    [J]. AFRICAN VISION AND EYE HEALTH JOURNAL, 2019, 78 (01):
  • [42] High Heritability of Posterior Corneal Tomography, as Measured by Scheimpflug Imaging, in a Twin Study
    Mahroo, Omar A.
    Oomerjee, Mohammed
    Williams, Katie M.
    O'Brart, David P. S.
    Hammond, Christopher J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (12) : 8359 - 8364
  • [43] CENTRAL MACULAR THICKNESS MEASUREMENTS IN YOUNG ADULTS MEASURED BY SPECTRALIS OPTICAL COHERENCE TOMOGRAPHY
    Tan, Alexander
    Chen, Fred
    Forward, Hannah
    Mountain, Jenny
    Newnham, John
    Pennell, Craig
    Mackey, David
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 : 71 - 71
  • [44] Reproducibility and Daytime-Dependent Changes of Corneal Epithelial Thickness and Whole Corneal Thickness Measured With Fourier Domain Optical Coherence Tomography
    Wasielica-Poslednik, Joanna
    Lisch, Walter
    Bell, Katharina
    Weyer, Veronika
    Pfeiffer, Norbert
    Gericke, Adrian
    [J]. CORNEA, 2016, 35 (03) : 342 - 349
  • [45] Influence of contact lens wearing on whole corneal thickness and corneal epithelial thickness measured with Fourier-domain optical coherence tomography
    Wasielica-Poslednik, Joanna
    Sievers, Marcel Sebastian
    Lisch, Walter
    Weyer, Veronika
    Pfeiffer, Norbert
    Gericke, Adrian
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [46] Inter-changeability Between Anterior Segment Optical Coherence Tomography and Scheimpflug Imaging in the Evaluation of Corneal Opacity
    Mounir, Amr
    Abdellah, Marwa Mahmoud
    Zidan, Omar Fawzy
    Mostafa, Engy Mohamed
    [J]. OPEN OPHTHALMOLOGY JOURNAL, 2022, 16
  • [47] Corneal Tomography in a Commercially Available Optical Coherence Tomography Device and Comparison With a Rotating Scheimpflug Camera
    Kanclerz, Piotr
    Radomski, Szymon Adam
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (03): : 138 - 144
  • [48] Choroidal thickness in pregnant women measured by enhanced depth imaging optical coherence tomography
    Junichi Takahashi
    Masanori Kado
    Keiko Mizumoto
    Sho Igarashi
    Tsunemaro Kojo
    [J]. Japanese Journal of Ophthalmology, 2013, 57 : 435 - 439
  • [49] Choroidal thickness in pregnant women measured by enhanced depth imaging optical coherence tomography
    Takahashi, Junichi
    Kado, Masanori
    Mizumoto, Keiko
    Igarashi, Sho
    Kojo, Tsunemaro
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2013, 57 (05) : 435 - 439
  • [50] Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    Barkana, Y
    Gerber, Y
    Elbaz, U
    Schwartz, S
    Ken-Dror, G
    Avni, I
    Zadok, D
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09): : 1729 - 1735