Central and Midperipheral Corneal Thickness Measured with Scheimpflug Imaging and Optical Coherence Tomography

被引:13
|
作者
Huang, Jinhai [1 ,2 ,3 ]
Ding, Xixia [1 ,2 ,3 ]
Savini, Giacomo [1 ,2 ,4 ]
Jiang, Zhengxuan [5 ]
Pan, Chao [1 ,2 ]
Hua, Yanjun [1 ,2 ]
Wu, Fan [1 ,2 ]
Feng, Yifan [1 ,2 ]
Yu, Ye [1 ,2 ]
Wang, Qinmei [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Sch Optometry & Ophthalmol, Wenzhou, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Hosp Eye, Wenzhou, Zhejiang, Peoples R China
[3] Minist Hlth PR China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[4] Studio Oculist DAzeglio, Bologna, Italy
[5] Anhui Med Univ, Affiliated Hosp 2, Hefei, Anhui, Peoples R China
来源
PLOS ONE | 2014年 / 9卷 / 05期
关键词
ANTERIOR SEGMENT MEASUREMENTS; PACHYMETRY MEASUREMENTS; ULTRASONIC PACHYMETRY; DIURNAL-VARIATION; CONTACT-LENS; REPEATABILITY; REPRODUCIBILITY; AGREEMENT; GALILEI; INTRAOBSERVER;
D O I
10.1371/journal.pone.0098316
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: To compare corneal thickness measurements using Pentacam (Oculus, Germany), Sirius (CSO, Italy), Galilei (Ziemer, Switzerland), and RTVue-100 OCT (Optovue Inc., USA). Methods: Sixty-six eyes of 66 healthy volunteers were enrolled. Three consecutive measurements were performed with each device. The mean value of the three measurements was used for subsequent analysis. Central corneal thickness (CCT), thinnest corneal thickness (TCT), and midperipheral corneal thickness (MPCT; measured at superior, inferior, nasal, and temporal locations with a distance of 1 mm (CT2mm) or 2.5 mm (CT5mm) from the corneal apex) were analyzed. Differences and agreement between measurements were assessed using the repeated-measures analysis of variance (ANOVA) and Bland-Altman analyses, respectively. Results: Statistically significant differences (p<0.001) among the four devices were revealed in CCT, TCT and CT2mm measurements. The CCT, TCT, and CT2mm values were ranked from the thickest to the thinnest as follows: Galilei>Sirius>Pentacam>RTVue OCT. For these measurements, agreement between measurements by Sirius and Pentacam was good, whereas Galilei overestimated and RTVue underestimated corneal thickness compared to Sirius and Pentacam. As regards CT5mm measurements, Pentacam provided the largest values, whereas RTVue OCT yielded the smallest values. Agreement of the CT5mm measurements was good between the Pentacam, Sirius, moderate between Galilei and the other two Scheimpflug systems, and poor between the RTVue OCT and the remaining devices. Conclusions: The Pentacam and Sirius can be used interchangeably for CCT measurements, while the Galilei and RTVue systematically over- and underestimate CCT, respectively. The three Scheimpflug cameras, but not the RTVue, may be used interchangeably for MPCT measurements.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A Comparison between Scheimpflug Imaging and Optical Coherence Tomography in Measuring Corneal Thickness
    Huang, Jinhai
    Ding, Xixia
    Savini, Giacomo
    Pan, Chao
    Feng, Yifan
    Cheng, Dan
    Hua, Yanjun
    Hu, Xiuli
    Wang, Qinmei
    [J]. OPHTHALMOLOGY, 2013, 120 (10) : 1951 - 1958
  • [2] Correlation of corneal thickness and volume with intraoperative phacoemulsification parameters using Scheimpflug imaging and optical coherence tomography
    Wong, Melissa M.
    Shukla, Anita N.
    Munir, Wuqaas M.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12): : 2067 - 2075
  • [3] Comparison of central corneal thickness measured by automatic and manual analysis of optical coherence tomography
    Carlo Bruttini
    Roberto Esposti
    Alfredo Pece
    Giulio Maione
    Paolo Cavallari
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1857 - 1863
  • [4] Impact of pterygium on central corneal thickness measured by optical coherence tomography in older adults
    Dotto, Pedro Gabriel
    Salomao, Solange Rios
    Fernandes, Arthur Gustavo
    Mitsuhiro, Marcia Regina Kimie Higashi
    Ferraz, Nivea Nunes
    Furtado, Joao Marcello
    Watanabe, Sung Song
    Cypel, Marcela
    Sacai, Paula Yuri
    Cunha, Cristina Coimbra
    Vasconcelos, Galton Carvalho
    Morales, Paulo Henrique
    Cohen, Marcos Jacob
    Cohen, Jacob Moyses
    Campos, Mauro
    Munoz, Sergio
    Belfort Jr, Rubens
    Berezovsky, Adriana
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (04) : 1583 - 1588
  • [5] Comparison of central corneal thickness measured by automatic and manual analysis of optical coherence tomography
    Bruttini, Carlo
    Esposti, Roberto
    Pece, Alfredo
    Maione, Giulio
    Cavallari, Paolo
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (06) : 1857 - 1863
  • [6] The effect of oxybuprocaine on corneal thickness as measured with optical coherence tomography
    Govender, Rowen
    Seedat, Zainab Y.
    Ramdass, Aristha
    Hansraj, Rekha
    Gcabashe, Nonkululeko M.
    [J]. AFRICAN VISION AND EYE HEALTH JOURNAL, 2016, 75 (01):
  • [7] Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry
    Chen, Shihao
    Huang, Jinhai
    Wen, Daizong
    Chen, Wuhe
    Huang, David
    Wang, Qinmei
    [J]. ACTA OPHTHALMOLOGICA, 2012, 90 (05) : 449 - 455
  • [8] Integrated line-field optical coherence tomography and scheimpflug imaging for corneal imaging
    Li, Xiaoran
    Lawman, Samuel
    Dong, Biqin
    Lin, Hungyen
    Shen, Yaochun
    Zheng, Yalin
    [J]. OPTICS AND LASERS IN ENGINEERING, 2024, 182
  • [9] Comparison of central corneal thickness measurements using optical low-coherence reflectometry, Fourier domain optical coherence tomography, and Scheimpflug camera
    Gonul, Saban
    Koktekir, Bengu Ekinci
    Bakbak, Berker
    Gedik, Sansal
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (06) : 345 - 350
  • [10] Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes
    Prospero Ponce, Claudia Maria
    Rocha, Karolinne Maia
    Smith, Scott D.
    Krueger, Ronald R.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06): : 1055 - 1062