Time-resolved fluoroimmunoassay of plasma daidzein and genistein

被引:86
|
作者
Wang, GJ
Lapcík, O
Hampl, R
Uehara, M
Al-Maharik, N
Stumpf, K
Mikola, H
Wähälä, K
Adlercreutz, H [1 ]
机构
[1] Univ Helsinki, Dept Clin Chem, Folkhalsan Res Ctr, Inst Prevent Med Nutr & Canc, Helsinki, Finland
[2] Inst Endocrinol, Prague, Czech Republic
[3] Univ Helsinki, Dept Clin Chem, Organ Chem Lab, Helsinki, Finland
[4] Wallac Oy, FIN-20101 Turku, Finland
关键词
immunoassay; phytoestrogens; isoflavones; time-resolved fluorescence; daidzein; genistein;
D O I
10.1016/S0039-128X(00)00089-1
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We present a method for the determination of the phytoestrogens daidzein and genistein in plasma (serum). These weakly estrogenic isoflavones occur in soybeans and in smaller amounts in some other beans and plants. It has been suggested that they may afford protection against prostate and breast cancer. The method is based on time-resolved fluoroimmunoassay (TR-FIA) using a europium chelate as a label. After synthesis of 4'-O-carboxymethyl-daidzein and 4'-O-carboxymethyl-genistein the compounds are coupled to bovine serum albumin (BSA), then used as antigens to immunize rabbits. The tracers with the europium chelate are synthesized using the same 4'-O-derivative of the isoflavones. After enzymatic hydrolysis and ether extraction the immunoassay is carried out using the VICTOR 1420 multilabel counter (Wallac Oy, Turku, Finland). The antisera cross-reacted to some extent with some isoflavonoids but not with flavonoids. The cross-reactivity seems not to influence the results, which were highly specific for both compounds. The correlation coefficients between the TR-FIA methods and the reference method based on isotope dilution gas chromatography-mass spectrometry were high; r-values were about 0.95-0.99 depending on concentration. The intra-assay coefficients of variation (CV%) for daidzein and genistein at three different concentrations vary 3.2-4.5 and 3.2-4.1, respectively. The inter-assay CVs vary 5.0-6.3 and 4.5-5.3, respectively. The working ranges of the daidzein and genistein assays are 1.0-216 and 1.7-370 nmol/l, respectively. The plasma values (n = 80) of daidzein and genistein are very low in Finnish subjects (mean for daidzein, 3.8 +/- 6.8 and for genistein, 3.2 +/- 7.6 nmol/l; median value for daidzein 1.5 and for genistein 1.4 nmol/l). (C) 2000 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:339 / 348
页数:10
相关论文
共 50 条
  • [1] Time-resolved fluoroimmunoassay for plasma enterolactone
    Adlercreutz, H
    Wang, GJJ
    Lapcík, O
    Hampl, R
    Wähälä, K
    Mäkelä, T
    Lusa, K
    Talme, M
    Mikola, H
    [J]. ANALYTICAL BIOCHEMISTRY, 1998, 265 (02) : 208 - 215
  • [2] TIME-RESOLVED FLUOROIMMUNOASSAY FOR SECRETIN IN HUMAN PLASMA
    ITO, K
    MAEDA, M
    TSUJI, A
    [J]. BUNSEKI KAGAKU, 1992, 41 (12) : 627 - 632
  • [3] Time-resolved fluoroimmunoassay for equol in plasma and urine
    Brouwers, E
    L'homme, R
    Al-Maharik, N
    Lapcík, O
    Hampl, R
    Wähälä, K
    Mikola, H
    Adlercreutz, H
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2003, 84 (05): : 577 - 588
  • [4] Changes in the time-resolved fluoroimmunoassay of plasma enterolactone
    Stumpf, K
    Uehara, M
    Nurmi, T
    Adlercreutz, H
    [J]. ANALYTICAL BIOCHEMISTRY, 2000, 284 (01) : 153 - 157
  • [5] Time-resolved fluoroimmunoassay
    Degan, P
    Podestà, A
    Montagnoli, G
    [J]. MOLECULAR BIOTECHNOLOGY, 1999, 13 (03) : 215 - 222
  • [6] Time-resolved fluoroimmunoassay
    Paolo Degan
    Adriano Podestà
    Giorgio Montagnoli
    [J]. Molecular Biotechnology, 1999, 13 : 215 - 222
  • [7] TIME-RESOLVED FLUOROIMMUNOASSAY OF AFLATOXINS
    DEGAN, P
    MONTAGNOLI, G
    WILD, CP
    [J]. CLINICAL CHEMISTRY, 1989, 35 (12) : 2308 - 2310
  • [8] Time-resolved fluoroimmunoassay of plasma and urine O-desmethylangolensin
    L'homme, R
    Brouwers, E
    Al-Maharik, N
    Lapcík, O
    Hampl, R
    Mikola, H
    Wähälä, K
    Adlercreutz, H
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2002, 81 (4-5): : 353 - 361
  • [9] Ultrasensitive time-resolved fluoroimmunoassay of ochratoxin A
    Huang, B
    Tao, WY
    Zhang, LF
    Shi, J
    Yang, HL
    Jin, J
    [J]. PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2005, 32 (07) : 662 - 666
  • [10] A TIME-RESOLVED FLUOROIMMUNOASSAY FOR FERRITIN IN SERUM
    CHAN, MA
    BELLEM, AC
    DIAMANDIS, EP
    [J]. CLINICAL BIOCHEMISTRY, 1987, 20 (04) : 294 - 294