Time-resolved fluoroimmunoassay of plasma daidzein and genistein

被引:86
|
作者
Wang, GJ
Lapcík, O
Hampl, R
Uehara, M
Al-Maharik, N
Stumpf, K
Mikola, H
Wähälä, K
Adlercreutz, H [1 ]
机构
[1] Univ Helsinki, Dept Clin Chem, Folkhalsan Res Ctr, Inst Prevent Med Nutr & Canc, Helsinki, Finland
[2] Inst Endocrinol, Prague, Czech Republic
[3] Univ Helsinki, Dept Clin Chem, Organ Chem Lab, Helsinki, Finland
[4] Wallac Oy, FIN-20101 Turku, Finland
关键词
immunoassay; phytoestrogens; isoflavones; time-resolved fluorescence; daidzein; genistein;
D O I
10.1016/S0039-128X(00)00089-1
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We present a method for the determination of the phytoestrogens daidzein and genistein in plasma (serum). These weakly estrogenic isoflavones occur in soybeans and in smaller amounts in some other beans and plants. It has been suggested that they may afford protection against prostate and breast cancer. The method is based on time-resolved fluoroimmunoassay (TR-FIA) using a europium chelate as a label. After synthesis of 4'-O-carboxymethyl-daidzein and 4'-O-carboxymethyl-genistein the compounds are coupled to bovine serum albumin (BSA), then used as antigens to immunize rabbits. The tracers with the europium chelate are synthesized using the same 4'-O-derivative of the isoflavones. After enzymatic hydrolysis and ether extraction the immunoassay is carried out using the VICTOR 1420 multilabel counter (Wallac Oy, Turku, Finland). The antisera cross-reacted to some extent with some isoflavonoids but not with flavonoids. The cross-reactivity seems not to influence the results, which were highly specific for both compounds. The correlation coefficients between the TR-FIA methods and the reference method based on isotope dilution gas chromatography-mass spectrometry were high; r-values were about 0.95-0.99 depending on concentration. The intra-assay coefficients of variation (CV%) for daidzein and genistein at three different concentrations vary 3.2-4.5 and 3.2-4.1, respectively. The inter-assay CVs vary 5.0-6.3 and 4.5-5.3, respectively. The working ranges of the daidzein and genistein assays are 1.0-216 and 1.7-370 nmol/l, respectively. The plasma values (n = 80) of daidzein and genistein are very low in Finnish subjects (mean for daidzein, 3.8 +/- 6.8 and for genistein, 3.2 +/- 7.6 nmol/l; median value for daidzein 1.5 and for genistein 1.4 nmol/l). (C) 2000 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:339 / 348
页数:10
相关论文
共 50 条
  • [41] Improvement in time-resolved fluoroimmunoassay sensitivity for carbofuran.
    Bacigalupo, MA
    Meroni, G
    [J]. PESTICIDE IN AIR, PLANT, SOIL & WATER SYSTEM, 2003, : 823 - 829
  • [42] USE OF SECTIONAL POLYSTYRENE PLATES IN TIME-RESOLVED FLUOROIMMUNOASSAY
    POMELOVA, VG
    SOKOLOVA, MV
    KHRISTOVA, ML
    LEONOV, SV
    LAVROVA, NA
    BYCHENKOVA, TA
    BUSEL, YP
    ZLOBIN, VN
    KHARITONENKOV, IG
    GAIDAMOVICH, SY
    [J]. LABORATORNOE DELO, 1991, (11): : 55 - 58
  • [43] SENSITIVE TIME-RESOLVED FLUOROIMMUNOASSAY OF SALMON-CALCITONIN
    RONG, HQ
    TORRING, O
    SAAF, M
    SJOSTEDT, U
    SJOBERG, HE
    BUCHT, E
    [J]. CLINICAL CHEMISTRY, 1994, 40 (09) : 1774 - 1777
  • [44] TIME-RESOLVED FLUOROIMMUNOASSAY IN THE DETECTION OF PLANT-VIRUSES
    SIITARI, H
    KURPPA, A
    [J]. JOURNAL OF GENERAL VIROLOGY, 1987, 68 : 1423 - 1428
  • [45] Direct time-resolved fluoroimmunoassay of serum and salivary cortisol
    Jelic, S
    Han, R
    Brkic, B
    Dimkovic, S
    [J]. JUGOSLOVENSKA MEDICINSKA BIOHEMIJA-YUGOSLAV MEDICAL BIOCHEMISTRY, 2000, 19 (04): : 401 - 405
  • [46] EUROPIUM LABELED TIME-RESOLVED FLUOROIMMUNOASSAY FOR URINE ALBUMIN
    NISBET, JA
    HUTCHINSON, E
    MAZURKIEWICZ, J
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1993, 30 : 223 - 224
  • [47] TIME-RESOLVED FLUOROIMMUNOASSAY OF CARDIAC TROPONIN-I
    ALEX, K
    MARIA, S
    ESKOLA, J
    PETTERSSON, K
    LOVGREN, T
    ANASTASIA, B
    NIKOLAI, G
    [J]. CLINICAL CHEMISTRY, 1995, 41 (06) : S53 - S53
  • [48] A SIMPLE TIME-RESOLVED FLUOROIMMUNOASSAY OF TOTAL THYROXINE IN SERUM
    PAPANASTASIOUDIAMANDIS, A
    BHAYANA, V
    DIAMANDIS, EP
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1989, 26 : 238 - 243
  • [49] SCREENING FOR CONGENITAL HYPOTHYROIDISM BY TIME-RESOLVED FLUOROIMMUNOASSAY FOR THYROTROPIN
    SANDER, J
    NIEHAUS, C
    [J]. CLINICAL CHEMISTRY, 1986, 32 (06) : 1231 - 1231
  • [50] A TIME-RESOLVED FLUOROIMMUNOASSAY FOR THE MEASUREMENT OF THYROXINE BINDING GLOBULIN
    MAKINEN, ML
    PETTERSSON, K
    SUONPAA, M
    [J]. CLINICAL CHEMISTRY, 1989, 35 (06) : 1205 - 1205