Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis

被引:4
|
作者
Kievit, A. J. [1 ,2 ]
Dobbe, J. G. G. [3 ]
Streekstra, G. J. [3 ]
Blankevoort, L. [1 ]
Schafroth, M. U. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Orthopaed Res Ctr Amsterdam, Dept Orthopaed Surg,Amsterdam Movement Sci, NL-1100 DE Amsterdam, Netherlands
[2] Tergooi Hosp, Dept Orthoped, Hilversum, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Biomed Engn & Phys, NL-1100 DE Amsterdam, Netherlands
关键词
Total knee arthroplasty; Biomet Signature; patient-specific instrumentation; Accuracy study; 3D Analysis; CT; REPLACEMENT; NAVIGATION; GUIDES; ALIGNMENT; SURGERY; SYSTEM; TKA;
D O I
10.1007/s00167-017-4721-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Malalignment of implants is a major source of failure during total knee arthroplasty. To achieve more accurate 3D planning and execution of the osteotomy cuts during surgery, the Signature (Biomet, Warsaw) patient-specific instrumentation (PSI) was used to produce pin guides for the positioning of the osteotomy blocks by means of computer-aided manufacture based on CT scan images. The research question of this study is: what is the transfer accuracy of osteotomy planes predicted by the Signature PSI system for preoperative 3D planning and intraoperative block-guided pin placement to perform total knee arthroplasty procedures? The transfer accuracy achieved by using the Signature PSI system was evaluated by comparing the osteotomy planes predicted preoperatively with the osteotomy planes seen intraoperatively in human cadaveric legs. Outcomes were measured in terms of translational and rotational errors (varus, valgus, flexion, extension and axial rotation) for both tibia and femur osteotomies. Average translational errors between the osteotomy planes predicted using the Signature system and the actual osteotomy planes achieved was 0.8 mm (+/- 0.5 mm) for the tibia and 0.7 mm (+/- 4.0 mm) for the femur. Average rotational errors in relation to predicted and achieved osteotomy planes were 0.1A degrees (+/- 1.2A degrees) of varus and 0.4A degrees (+/- 1.7A degrees) of anterior slope (extension) for the tibia, and 2.8A degrees (+/- 2.0A degrees) of varus and 0.9A degrees (+/- 2.7A degrees) of flexion and 1.4A degrees (+/- 2.2A degrees) of external rotation for the femur. The similarity between osteotomy planes predicted using the Signature system and osteotomy planes actually achieved was excellent for the tibia although some discrepancies were seen for the femur. The use of 3D system techniques in TKA surgery can provide accurate intraoperative guidance, especially for patients with deformed bone, tailored to individual patients and ensure better placement of the implant.
引用
收藏
页码:1751 / 1758
页数:8
相关论文
共 50 条
  • [41] Patient-specific instruments in total knee arthroplasty
    Fabio Conteduca
    Raffaele Iorio
    Daniele Mazza
    Andrea Ferretti
    International Orthopaedics, 2014, 38 : 259 - 265
  • [42] Accuracy and Reproducibility Using Patient-Specific Instrumentation in Total Ankle Arthroplasty
    Daigre, Justin
    Berlet, Gregory
    Van Dyke, Bryan
    Peterson, Kyle S.
    Santrock, Robert
    FOOT & ANKLE INTERNATIONAL, 2017, 38 (04) : 412 - 418
  • [43] Accuracy of a Patient-Specific Total Ankle Arthroplasty Instrumentation
    April, Pierre-Marc
    Locke, Eric
    Champagne, Philippe-Hugo
    Angers, Magalie
    Martinez-Gomez, Adriana Patricia
    Seidel, Angela
    Jibri, Zaid
    Lalonde, Karl-Andre
    Meulenkamp, Brad
    FOOT & ANKLE INTERNATIONAL, 2023, 44 (11) : 1150 - 1157
  • [44] Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes
    Kazumasa Yamamura
    Yukihide Minoda
    Ryo Sugama
    Yoichi Ohta
    Suguru Nakamura
    Hideki Ueyama
    Hiroaki Nakamura
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 1560 - 1567
  • [45] Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
    Mehdipour, Soheil
    Qoreishi, Mohamad
    Keipourfard, Ali
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2020, 8 (05): : 625 - 632
  • [46] Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes
    Yamamura, Kazumasa
    Minoda, Yukihide
    Sugama, Ryo
    Ohta, Yoichi
    Nakamura, Suguru
    Ueyama, Hideki
    Nakamura, Hiroaki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (05) : 1560 - 1567
  • [47] Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation
    Meng Zhu
    Jerry Yongqiang Chen
    Hwei Chi Chong
    Andy Khye Soon Yew
    Leon Siang Shen Foo
    Shi-Lu Chia
    Ngai Nung Lo
    Seng Jin Yeo
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2567 - 2572
  • [48] Functional Outcome and Quality of Life After Patient-Specific Instrumentation in Total Knee Arthroplasty
    Prakash, Jatin
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04): : 923 - 924
  • [49] Functional Outcome and Quality of Life after Patient-Specific Instrumentation in Total Knee Arthroplasty
    Chen, Jerry Yonggiang
    Chin, Pak Lin
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    JOURNAL OF ARTHROPLASTY, 2015, 30 (10): : 1724 - 1728
  • [50] Patient-specific instrumentation for total knee arthroplasty: Evaluation with computer-tomography tools
    Nabavi, Arash
    Olwill, Caroline M.
    Do, Mike
    Wanasawage, Tanya
    Harris, Ian A.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (01)