Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis

被引:4
|
作者
Kievit, A. J. [1 ,2 ]
Dobbe, J. G. G. [3 ]
Streekstra, G. J. [3 ]
Blankevoort, L. [1 ]
Schafroth, M. U. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Orthopaed Res Ctr Amsterdam, Dept Orthopaed Surg,Amsterdam Movement Sci, NL-1100 DE Amsterdam, Netherlands
[2] Tergooi Hosp, Dept Orthoped, Hilversum, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Biomed Engn & Phys, NL-1100 DE Amsterdam, Netherlands
关键词
Total knee arthroplasty; Biomet Signature; patient-specific instrumentation; Accuracy study; 3D Analysis; CT; REPLACEMENT; NAVIGATION; GUIDES; ALIGNMENT; SURGERY; SYSTEM; TKA;
D O I
10.1007/s00167-017-4721-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Malalignment of implants is a major source of failure during total knee arthroplasty. To achieve more accurate 3D planning and execution of the osteotomy cuts during surgery, the Signature (Biomet, Warsaw) patient-specific instrumentation (PSI) was used to produce pin guides for the positioning of the osteotomy blocks by means of computer-aided manufacture based on CT scan images. The research question of this study is: what is the transfer accuracy of osteotomy planes predicted by the Signature PSI system for preoperative 3D planning and intraoperative block-guided pin placement to perform total knee arthroplasty procedures? The transfer accuracy achieved by using the Signature PSI system was evaluated by comparing the osteotomy planes predicted preoperatively with the osteotomy planes seen intraoperatively in human cadaveric legs. Outcomes were measured in terms of translational and rotational errors (varus, valgus, flexion, extension and axial rotation) for both tibia and femur osteotomies. Average translational errors between the osteotomy planes predicted using the Signature system and the actual osteotomy planes achieved was 0.8 mm (+/- 0.5 mm) for the tibia and 0.7 mm (+/- 4.0 mm) for the femur. Average rotational errors in relation to predicted and achieved osteotomy planes were 0.1A degrees (+/- 1.2A degrees) of varus and 0.4A degrees (+/- 1.7A degrees) of anterior slope (extension) for the tibia, and 2.8A degrees (+/- 2.0A degrees) of varus and 0.9A degrees (+/- 2.7A degrees) of flexion and 1.4A degrees (+/- 2.2A degrees) of external rotation for the femur. The similarity between osteotomy planes predicted using the Signature system and osteotomy planes actually achieved was excellent for the tibia although some discrepancies were seen for the femur. The use of 3D system techniques in TKA surgery can provide accurate intraoperative guidance, especially for patients with deformed bone, tailored to individual patients and ensure better placement of the implant.
引用
收藏
页码:1751 / 1758
页数:8
相关论文
共 50 条
  • [21] Safe and Accurate Utilization of Patient-specific Guides in Total Knee Arthroplasty
    Patel, Anay R.
    Ghate, Raju
    Stulberg, Samuel David
    TECHNIQUES IN ORTHOPAEDICS, 2013, 28 (02) : 191 - 199
  • [22] Patient-specific instrumentation in total ankle arthroplasty
    Mazzotti, Antonio
    Arceri, Alberto
    Zielli, Simone
    Bonelli, Simone
    Viglione, Valentina
    Faldini, Cesare
    WORLD JOURNAL OF ORTHOPEDICS, 2022, 13 (03): : 230 - 237
  • [23] Patient-specific instrumentation for total shoulder arthroplasty
    Gomes, Nuno Sampaio
    EFORT OPEN REVIEWS, 2016, 1 (05): : 177 - 182
  • [24] Accuracy and efficacy of osteotomy in total knee arthroplasty with patient-specific navigational template
    Gan, Yudong
    Ding, Jing
    Xu, Yongqing
    Hou, Chunlin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08): : 12192 - 12201
  • [25] Patient-specific instrumentation in total knee arthroplasty: simpler, faster and more accurate than standard instrumentation—a randomized controlled trial
    João Vide
    Tânia Pinto Freitas
    Acácio Ramos
    Henrique Cruz
    João Paulo Sousa
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2616 - 2621
  • [26] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Chen, Jerry Yongqiang
    Yeo, Seng Jin
    Yew, Andy Khye Soon
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Chin, Pak Lin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (03) : 630 - 635
  • [27] Patient-Specific Instrumentation in Total Knee Arthroplasty Provides No Improvement in Component Alignment
    Stronach, Benjamin M.
    Pelt, Christopher E.
    Erickson, Jill A.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 1705 - 1708
  • [28] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Jerry Yongqiang Chen
    Seng Jin Yeo
    Andy Khye Soon Yew
    Darren Keng Jin Tay
    Shi-Lu Chia
    Ngai Nung Lo
    Pak Lin Chin
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 630 - 635
  • [29] Reducing Blood Loss in Bilateral Total Knee Arthroplasty with Patient-Specific Instrumentation
    Rathod, Parthiv A.
    Deshmukh, Ajit J.
    Cushner, Fred D.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (03) : 343 - +
  • [30] Preoperative corrections are required for planning of patient-specific instrumentation in total knee arthroplasty
    Okada, Yohei
    Teramoto, Atsushi
    Suzuki, Tomoyuki
    Kii, Yuichiro
    Watanabe, Kota
    Yamashita, Toshihiko
    KNEE, 2017, 24 (06): : 1492 - 1497