Active thermography is an infrared-based technique for nondestructive testing of materials. It often uses advanced evaluation techniques based on temperature spatial and temporal changes. Results of active thermography are contrast differences, which indicate possible defects in an inspected material. These differences cannot be quantified by temperature. This contribution is focused on the active thermography results' evaluation parameters and the contrast-to-noise ratio method, which can be used for quantitative evaluation of the results. Different result interpretation procedures are introduced. The influence of a selection method for indication and reference regions and the effect of image scaling on inspection results are discussed. (C) 2018 Optical Society of America
引用
收藏
页码:D49 / D55
页数:7
相关论文
共 50 条
  • [31] Signal-to-noise ratio, contrast-to-noise ratio, and exposure time for imaging systems with photon-limited noise
    Lucke, Robert L.
    Kessel, Robert A.
    OPTICAL ENGINEERING, 2006, 45 (05)
  • [32] Radiometry and contrast-to-noise ratio for continuous-wave and laser range-gated active imaging systems
    Follansbee, Joshua
    Burrell, Derek
    Furxhi, Orges
    Renshaw, C. Kyle
    Driggers, Ronald G.
    APPLIED OPTICS, 2023, 62 (35) : 9317 - 9325
  • [33] Signal-to-noise ratio, contrast-to-noise ratio and pharmacokinetic modeling considerations in dynamic contrast-enhanced magnetic resonance imaging
    Li, Xin
    Huang, Wei
    Rooney, William D.
    MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1313 - 1322
  • [34] Effect of kVp on Noise, Dose, and Contrast-to-Noise Ratio for Pediatric Low-Dose CT
    Gamberoni, J.
    Dong, F.
    Davros, B.
    Reid, J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [35] Influence of detector response speed on the contrast-to-noise ratio of reflective ghost imaging
    Li, Hong-Guo
    Zhang, De-Jian
    Zhao, Qiu-Li
    Wang, Sen
    Wang, Hai-Bo
    Xiong, Jun
    OPTICS COMMUNICATIONS, 2015, 355 : 558 - 561
  • [36] Contrast-to-noise ratio and histogram analysis of modified digital radiography image of pet
    Susilo
    Masturi
    Susanti, R.
    Yulianti, Ian
    Fatimah, Q.
    UNNES PHYSICS INTERNATIONAL SYMPOSIUM 2018 (UPIS2018), 2019, 1170
  • [37] Optimizing Image Quality and Dose for Digital Radiography of Distal Pediatric Extremities Using the Contrast-to-Noise Ratio
    Hess, R.
    Neitzel, U.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (07): : 643 - 649
  • [38] Temporal averaging introduced in linear regression beamforming for improvement of contrast-to-noise ratio
    Hasegawa, Hideyuki
    Nagaoka, Ryo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (59)
  • [39] Quantitative susceptibility mapping across two clinical field strengths: Contrast-to-noise ratio enhancement at 1.5T
    Ippoliti, Matteo
    Adams, Lisa C.
    Winfried, Brenner
    Hamm, Bernd
    Spincemaille, Pascal
    Wang, Yi
    Makowski, Marcus R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (05) : 1410 - 1420
  • [40] Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods
    Chatzaraki, Vasiliki
    Kubik-Huch, Rahel A.
    Thali, Michael
    Niemann, Tilo
    ACTA RADIOLOGICA, 2022, 63 (10) : 1353 - 1362