Quantitative evaluation of active thermography using contrast-to-noise ratio

被引:20
|
作者
Svantner, M. [1 ]
Muzika, L. [1 ]
Chmelik, T. [1 ]
Skala, J. [1 ]
机构
[1] Univ West Bohemia, New Technol Res Ctr, Univ 8, Plzen 30614, Czech Republic
关键词
COMPOSITES; INSPECTION;
D O I
10.1364/AO.57.000D49
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Active thermography is an infrared-based technique for nondestructive testing of materials. It often uses advanced evaluation techniques based on temperature spatial and temporal changes. Results of active thermography are contrast differences, which indicate possible defects in an inspected material. These differences cannot be quantified by temperature. This contribution is focused on the active thermography results' evaluation parameters and the contrast-to-noise ratio method, which can be used for quantitative evaluation of the results. Different result interpretation procedures are introduced. The influence of a selection method for indication and reference regions and the effect of image scaling on inspection results are discussed. (C) 2018 Optical Society of America
引用
收藏
页码:D49 / D55
页数:7
相关论文
共 50 条
  • [21] THE CONTRAST-TO-NOISE RATIO AS A MEASURE OF TISSUE CONTRAST IN MAGNETIC-RESONANCE-IMAGING
    BAIERL, P
    SEIDERER, M
    HEYWANG, S
    RATH, M
    DIGITALE BILDDIAGNOSTIK, 1986, 6 (03): : 101 - 110
  • [22] Grayscale contrast enhancement based on grayscale-based contrast-to-noise ratio
    Zhou, Wei
    Tian, Yi
    Cai, Xiaolu
    Fei, Zhenyu
    MEDICAL IMAGING 2021: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2021, 11599
  • [23] Trabecular bone histomorphometric measurements and contrast-to-noise ratio in CBCT
    Klintstrom, E.
    Smedby, O.
    Klintstrom, B.
    Brismar, T. B.
    Moreno, R.
    DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (08)
  • [24] Validation of noise estimation for a clinical contrast-to-noise ratio for digital mammographic imaging
    Hill, Melissa L.
    Mackenzie, Alistair
    Khan, Nabeel
    Wang, Kaier
    Highnam, Ralph P.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [25] Improvement in CT Contrast-To-Noise Ratio in Low Contrast Spherical Simulated Liver Lesions Using Iterative Reconstruction
    Dong, F.
    Herts, B.
    Baker, M.
    Goenka, A.
    Primak, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [26] Modified pulse-phase thermography algorithms for improved contrast-to-noise ratio from pulse-excited thermographic sequences
    Netzelmann, Udo
    Mueller, David
    NDT & E INTERNATIONAL, 2020, 116
  • [27] Mammographic image quality assessment by a contrast-to-noise ratio for clinical images
    Hill, Melissa L.
    Mackenzie, Alistair
    Warren, Lucy M.
    Khan, Nabeel
    Wang, Kaier
    Highnam, Ralph P.
    15TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI2020), 2020, 11513
  • [28] Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner
    Mueller, Mark
    Yaroshenko, Andre
    Velroyen, Astrid
    Bech, Martin
    Tapfer, Arne
    Pauwels, Bart
    Bruyndonckx, Peter
    Sasov, Alexander
    Pfeiffer, Franz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12):
  • [29] Blind Estimation for Localized Low Contrast-to-Noise Ratio BOLD Signals
    Atkinson, Ian C.
    Kamalabadi, Farzad
    Jones, Douglas L.
    Thulborn, Keith R.
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2008, 2 (06) : 879 - 890
  • [30] Application of the generalized contrast-to-noise ratio to assess photoacoustic image quality
    Kempski, Kelley M.
    Graham, Michelle T.
    Gubbi, Mardava R.
    Palmer, Theron
    Bell, Muyinatu A. Lediju
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (07) : 3684 - 3698