Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods

被引:1
|
作者
Chatzaraki, Vasiliki [1 ,2 ]
Kubik-Huch, Rahel A. [1 ]
Thali, Michael [2 ]
Niemann, Tilo [1 ]
机构
[1] Kantonsspital Baden, Inst Radiol, Ergel 1, CH-5404 Baden, Switzerland
[2] Univ Zurich, Inst Forens Med, Zurich, Switzerland
关键词
Computed tomography angiography; thorax; radiographic image enhancement; contrast to noise ratio; image enhancement; TUBE-VOLTAGE SELECTION; AORTIC CT ANGIOGRAPHY; ITERATIVE RECONSTRUCTION; PULMONARY-ARTERY; REDUCTION; OPACIFICATION; PROTOCOL; DETECTOR;
D O I
10.1177/02841851211041813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Contrast-to-noise ratio is used to objectively evaluate image quality in chest computed tomography angiography (CTA). Different authors define and measure contrast-to-noise ratio using different methods. Purpose To summarize and evaluate the different contrast-to-noise ratio calculation formulas in the current literature. Material and Methods A systematic review of the recent literature for studies using contrast-to-noise ratio was performed. Contrast-to-noise ratio measurement methods reported by the different authors were recorded and reproduced in three patients who underwent chest CTA in our department for exploring variations among the different measurement methods. Results The search resulted in 109 articles, of which 26 were included. The studies involved 69 different measurements and overall, three different formula patterns. In all three, aorta and pulmonary arteries comprised the objects of interest in the numerator. In the denominator, standard deviation of the attenuation of the object of interest itself or of another background were used to reflect image noise. Some authors averaged the ratio values at different levels to obtain global ratio values. Using the object of interest itself for image noise calculation in the denominator compared to the usage of another background caused the most prominent variances of contrast-to-noise ratio between the two different protocols used for the reproduction of the measurements. Conclusion We recommend using the standard deviation of the attenuation of a background indicator as image noise rather than the object of interest itself for more reliable and comparative values. Global contrast-to-noise ratios based on averaging the values of different measurement levels should be avoided.
引用
下载
收藏
页码:1353 / 1362
页数:10
相关论文
共 50 条
  • [1] Measurement of contrast-to-noise ratio for differential phase contrast computed tomography
    Zambelli, Joseph
    Bevins, Nicholas
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [2] Contrast-to-Noise Ratio Optimization in Coronary Computed Tomography Angiography: Validation in a Swine Model
    Hubbard, Logan
    Malkasian, Shant
    Zhao, Yixiao
    Abbona, Pablo
    Molloi, Sabee
    ACADEMIC RADIOLOGY, 2019, 26 (06) : E115 - E125
  • [3] The Contrast-to-Noise Ratio for Image Quality Evaluation in Scanning Electron Microscopy
    Timischl, F.
    SCANNING, 2015, 37 (01) : 54 - 62
  • [4] Image fusion in dual energy computed tomography for detection of various anatomic structures - Effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality
    Paul, Jijo
    Bauer, Ralf W.
    Maentele, Werner
    Vogl, Thomas J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 612 - 619
  • [5] Image Fusion in Dual Energy Computed Tomography Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography
    Behrendt, Florian F.
    Schmidt, Bernhard
    Plumhans, Cedric
    Keil, Sebastian
    Woodruff, Seth G.
    Ackermann, Diana
    Muehlenbruch, Georg
    Flohr, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 1 - 6
  • [6] Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner
    Mueller, Mark
    Yaroshenko, Andre
    Velroyen, Astrid
    Bech, Martin
    Tapfer, Arne
    Pauwels, Bart
    Bruyndonckx, Peter
    Sasov, Alexander
    Pfeiffer, Franz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12):
  • [7] Mammographic image quality assessment by a contrast-to-noise ratio for clinical images
    Hill, Melissa L.
    Mackenzie, Alistair
    Warren, Lucy M.
    Khan, Nabeel
    Wang, Kaier
    Highnam, Ralph P.
    15TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI2020), 2020, 11513
  • [8] Application of the generalized contrast-to-noise ratio to assess photoacoustic image quality
    Kempski, Kelley M.
    Graham, Michelle T.
    Gubbi, Mardava R.
    Palmer, Theron
    Bell, Muyinatu A. Lediju
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (07) : 3684 - 3698
  • [9] Quantification of Radiographic Image Quality Based on Patient Anatomical Contrast-to-Noise Ratio - A Preliminary Study with Chest Images
    Lin, Yuan
    Wang, Xiaohui
    Sehnert, William J.
    Foos, David H.
    Barski, Lori
    Samei, Ehsan
    MEDICAL IMAGING 2010: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2010, 7627
  • [10] Impact of a contrast-to-noise ratio driven and material specific exposure control on image quality and radiation exposure in angiography
    Werncke, Thomas
    Kemling, Marius
    Tashenov, Stanislav
    Hinrichs, Jan B.
    Meine, Timo C.
    Maschke, Sabine K.
    Kyriakou, Yiannis
    Wacker, Frank K.
    Meyer, Bernhard C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):