Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods

被引:1
|
作者
Chatzaraki, Vasiliki [1 ,2 ]
Kubik-Huch, Rahel A. [1 ]
Thali, Michael [2 ]
Niemann, Tilo [1 ]
机构
[1] Kantonsspital Baden, Inst Radiol, Ergel 1, CH-5404 Baden, Switzerland
[2] Univ Zurich, Inst Forens Med, Zurich, Switzerland
关键词
Computed tomography angiography; thorax; radiographic image enhancement; contrast to noise ratio; image enhancement; TUBE-VOLTAGE SELECTION; AORTIC CT ANGIOGRAPHY; ITERATIVE RECONSTRUCTION; PULMONARY-ARTERY; REDUCTION; OPACIFICATION; PROTOCOL; DETECTOR;
D O I
10.1177/02841851211041813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Contrast-to-noise ratio is used to objectively evaluate image quality in chest computed tomography angiography (CTA). Different authors define and measure contrast-to-noise ratio using different methods. Purpose To summarize and evaluate the different contrast-to-noise ratio calculation formulas in the current literature. Material and Methods A systematic review of the recent literature for studies using contrast-to-noise ratio was performed. Contrast-to-noise ratio measurement methods reported by the different authors were recorded and reproduced in three patients who underwent chest CTA in our department for exploring variations among the different measurement methods. Results The search resulted in 109 articles, of which 26 were included. The studies involved 69 different measurements and overall, three different formula patterns. In all three, aorta and pulmonary arteries comprised the objects of interest in the numerator. In the denominator, standard deviation of the attenuation of the object of interest itself or of another background were used to reflect image noise. Some authors averaged the ratio values at different levels to obtain global ratio values. Using the object of interest itself for image noise calculation in the denominator compared to the usage of another background caused the most prominent variances of contrast-to-noise ratio between the two different protocols used for the reproduction of the measurements. Conclusion We recommend using the standard deviation of the attenuation of a background indicator as image noise rather than the object of interest itself for more reliable and comparative values. Global contrast-to-noise ratios based on averaging the values of different measurement levels should be avoided.
引用
收藏
页码:1353 / 1362
页数:10
相关论文
共 50 条
  • [22] Optimizing Image Quality and Dose for Digital Radiography of Distal Pediatric Extremities Using the Contrast-to-Noise Ratio
    Hess, R.
    Neitzel, U.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (07): : 643 - 649
  • [23] Iodine potassium iodide improves the contrast-to-noise ratio of micro-computed tomography images of the human middle ear
    Rohani, S. A.
    Ghomashchi, S.
    Umoh, J.
    Holdsworth, D. W.
    Agrawal, S. K.
    Ladak, H. M.
    JOURNAL OF MICROSCOPY, 2016, 264 (03) : 334 - 338
  • [24] Contrast-to-noise ratios of different dental restorative materials: An in-vitro cone beam computed tomography study
    Bayrak, Seval
    Sebnem, Emine
    Kursun-Cakmak
    Kamalak, Hakan
    EUROPEAN ORAL RESEARCH, 2020, 54 (01) : 36 - 41
  • [25] Contrast-to-noise ratio with different large volumes in a cone-beam computerized tomography machine: An in vitro study
    Bechara, Boulos
    McMahan, C. Alex
    Moore, William S.
    Noujeim, Marcel
    Geha, Hassem
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (05): : 658 - 665
  • [26] Regional improvement of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in dual-screen computed radiography (CR) chest imaging: A phantom study
    Liu, X
    Chardon, SD
    Shaw, CC
    RADIOLOGY, 1998, 209P : 358 - 359
  • [27] Application of contrast-to-noise ratio in optimizing beam quality for digital chest radiography: comparison of experimental measurements and theoretical simulations
    Doyle, P.
    Martin, C. J.
    Gentle, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11): : 2953 - 2970
  • [28] Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies
    Gutjahr, Ralf
    Halaweish, Ahmed F.
    Yu, Zhicong
    Leng, Shuai
    Yu, Lifeng
    Li, Zhoubo
    Jorgensen, Steven M.
    Ritman, Erik L.
    Kappler, Steffen
    McCollough, Cynthia H.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (07) : 421 - 429
  • [29] Intraindividual evaluation of effects of image filter function on image quality in coronary computed tomography angiography
    Jin, Liang
    Gao, Pan
    Wang, Kun
    Li, Jianying
    Li, Ming
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [30] MR-ANGIOGRAPHY OF NORMAL PELVIC ARTERIES - COMPARISON OF SIGNAL INTENSITY AND CONTRAST-TO-NOISE RATIO FOR 3 DIFFERENT INFLOW TECHNIQUES
    YUCEL, EK
    SILVER, MS
    CARTER, AP
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) : 197 - 201