Iodine potassium iodide improves the contrast-to-noise ratio of micro-computed tomography images of the human middle ear

被引:10
|
作者
Rohani, S. A. [1 ]
Ghomashchi, S. [2 ]
Umoh, J. [3 ]
Holdsworth, D. W. [1 ,2 ,3 ]
Agrawal, S. K. [4 ]
Ladak, H. M. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Western Univ, Biomed Engn Grad Program, London, ON, Canada
[2] Western Univ, Dept Med Biophys, London, ON, Canada
[3] Robarts Res Inst, Imaging Res Labs, London, ON, Canada
[4] Western Univ, Dept Otolaryngol Head & Neck Surg, London, ON, Canada
[5] Western Univ, Dept Elect & Comp Engn, London, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Contrast; micro-computed tomography; middle ear; iodine potassium iodide; BONE; TISSUE; MODEL; CT;
D O I
10.1111/jmi.12447
中图分类号
TH742 [显微镜];
学科分类号
摘要
High-resolution imaging of middle-ear geometry is necessary for finite-element modeling. Although micro-computed tomography (microCT) is widely used because of its ability to image bony structures of the middle ear, it is difficult to visualize soft tissues - including the tympanic membrane and the suspensory ligaments/tendons - because of lack of contrast. The objective of this research is to quantitatively evaluate the efficacy of iodine potassium iodide (IKI) solution as a contrast agent. Six human temporal bones were used in this experiment, which were obtained in right-left pairs, from three cadaveric heads. All bones were fixed using formaldehyde. Three bones (one from each pair) were stained in IKI solution for 2 days, whereas the other three were not stained. Samples were scanned using a microCT system at a resolution of 20 m. Eight soft tissues in the middle ear were segmented: anterior mallear ligament, incudomallear joint, lateral mallear ligament, posterior incudal ligament, stapedial annular ligament, stapedius muscle, tympanic membrane and tensor tympani muscle. Contrast-to-noise ratios (CNRs) of each soft tissue were calculated for each temporal bone. Combined CNRs of the soft tissues in unstained samples were 6.1 3.0, whereas they were 8.1 +/- 2.7 in stained samples. Results from Welch's t-test indicate significant difference between the two groups at a 95% confidence interval. Results for paired t-tests for each of the individual soft tissues also indicated significant improvement of contrast in all tissues after staining. Relatively large soft tissues in the middle ear such as the tympanic membrane and the tensor tympani muscle were impacted by staining more than smaller tissues such as the stapedial annular ligament. The increase in contrast with IKI solution confirms its potential application in automatic segmentation of the middle-ear soft tissues. Lay description Micro-computed tomography (microCT) is a high resolution X-ray based imaging technique that can be used to visualize small structures in 3 dimensions. It is often used to image the small structures of the middle ear. Although microCT provides superb contrast for the bony structures of the middle ear, soft tissues such as the eardrum, muscles, tendons and ligaments are difficult to visualize because of poor contrast. The objective of this work was to investigate the efficacy of iodine potassium iodide (IKI) solution as a contrast-enhancement agent. Three cadaveric human middle ears were imaged after staining them with IKI, and another three were imaged without staining. Results indicate that IKI staining enhanced contrast of all middle-ear soft tissues, but it was most effective for larger tissues than smaller ones. In conclusion, IKI staining is useful for visualizing both the bony and soft-tissue structures of the middle ear.
引用
收藏
页码:334 / 338
页数:5
相关论文
共 36 条
  • [1] Measurement of contrast-to-noise ratio for differential phase contrast computed tomography
    Zambelli, Joseph
    Bevins, Nicholas
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [2] Iodine-based contrast staining improves micro-computed tomography of atherosclerotic coronary arteries
    Self, Trevor S.
    Ginn-Hedman, Anne-Marie
    Newell-Fugate, Annie E.
    Weeks, Brad R.
    Heaps, Cristine L.
    METHODSX, 2021, 8
  • [3] Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner
    Mueller, Mark
    Yaroshenko, Andre
    Velroyen, Astrid
    Bech, Martin
    Tapfer, Arne
    Pauwels, Bart
    Bruyndonckx, Peter
    Sasov, Alexander
    Pfeiffer, Franz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12):
  • [4] Contrast-to-Noise Ratio Optimization in Coronary Computed Tomography Angiography: Validation in a Swine Model
    Hubbard, Logan
    Malkasian, Shant
    Zhao, Yixiao
    Abbona, Pablo
    Molloi, Sabee
    ACADEMIC RADIOLOGY, 2019, 26 (06) : E115 - E125
  • [5] Effects of different tube potentials and iodine concentrations on image enhancement, contrast-to-noise ratio and noise in micro-CT images: a phantom study
    Razak, Hairil Rashmizal Abdul
    Rahmat, Said Mohd Shaffiq Said
    Saad, Wan Mazlina Md
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2013, 3 (05) : 256 - 261
  • [6] Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines
    Bechara, Boulos
    McMahan, Clyde A.
    Moore, William S.
    Noujeim, Marcel
    Geha, Hassem
    Teixeira, Fabricio B.
    JOURNAL OF ORAL SCIENCE, 2012, 54 (03) : 227 - 232
  • [7] Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies
    Gutjahr, Ralf
    Halaweish, Ahmed F.
    Yu, Zhicong
    Leng, Shuai
    Yu, Lifeng
    Li, Zhoubo
    Jorgensen, Steven M.
    Ritman, Erik L.
    Kappler, Steffen
    McCollough, Cynthia H.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (07) : 421 - 429
  • [8] Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods
    Chatzaraki, Vasiliki
    Kubik-Huch, Rahel A.
    Thali, Michael
    Niemann, Tilo
    ACTA RADIOLOGICA, 2022, 63 (10) : 1353 - 1362
  • [9] Accuracy and Precision of Iodine Quantification in Subtracted Micro-Computed Tomography: Effect of Reconstruction and Noise Removal Algorithms
    Ayala-Dominguez, Lizbeth
    Medina, Luis-Alberto
    Aceves, Carmen
    Lizano, Marcela
    Brandan, Maria-Ester
    MOLECULAR IMAGING AND BIOLOGY, 2023, 25 (06) : 1084 - 1093
  • [10] Accuracy and Precision of Iodine Quantification in Subtracted Micro-Computed Tomography: Effect of Reconstruction and Noise Removal Algorithms
    Lízbeth Ayala-Dominguez
    Luis-Alberto Medina
    Carmen Aceves
    Marcela Lizano
    Maria-Ester Brandan
    Molecular Imaging and Biology, 2023, 25 : 1084 - 1093