Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods

被引:1
|
作者
Chatzaraki, Vasiliki [1 ,2 ]
Kubik-Huch, Rahel A. [1 ]
Thali, Michael [2 ]
Niemann, Tilo [1 ]
机构
[1] Kantonsspital Baden, Inst Radiol, Ergel 1, CH-5404 Baden, Switzerland
[2] Univ Zurich, Inst Forens Med, Zurich, Switzerland
关键词
Computed tomography angiography; thorax; radiographic image enhancement; contrast to noise ratio; image enhancement; TUBE-VOLTAGE SELECTION; AORTIC CT ANGIOGRAPHY; ITERATIVE RECONSTRUCTION; PULMONARY-ARTERY; REDUCTION; OPACIFICATION; PROTOCOL; DETECTOR;
D O I
10.1177/02841851211041813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Contrast-to-noise ratio is used to objectively evaluate image quality in chest computed tomography angiography (CTA). Different authors define and measure contrast-to-noise ratio using different methods. Purpose To summarize and evaluate the different contrast-to-noise ratio calculation formulas in the current literature. Material and Methods A systematic review of the recent literature for studies using contrast-to-noise ratio was performed. Contrast-to-noise ratio measurement methods reported by the different authors were recorded and reproduced in three patients who underwent chest CTA in our department for exploring variations among the different measurement methods. Results The search resulted in 109 articles, of which 26 were included. The studies involved 69 different measurements and overall, three different formula patterns. In all three, aorta and pulmonary arteries comprised the objects of interest in the numerator. In the denominator, standard deviation of the attenuation of the object of interest itself or of another background were used to reflect image noise. Some authors averaged the ratio values at different levels to obtain global ratio values. Using the object of interest itself for image noise calculation in the denominator compared to the usage of another background caused the most prominent variances of contrast-to-noise ratio between the two different protocols used for the reproduction of the measurements. Conclusion We recommend using the standard deviation of the attenuation of a background indicator as image noise rather than the object of interest itself for more reliable and comparative values. Global contrast-to-noise ratios based on averaging the values of different measurement levels should be avoided.
引用
下载
收藏
页码:1353 / 1362
页数:10
相关论文
共 50 条
  • [31] IMAGE QUALITY EVALUATION IN PHASE CONTRAST COMPUTED TOMOGRAPHY FROM SYNCHROTRON-BEAMS RECONSTRUCTED BY ITERATIVE METHODS
    Marquez-Diaz, J.
    Orozco-Morales, R.
    Lorenzo-Ginori, J., V
    Perez-Diaz, M.
    REVISTA CUBANA DE FISICA, 2020, 37 (02): : 88 - 94
  • [32] Image quality of spectral brain computed tomography angiography using halved dose of iodine contrast medium
    Veronica Fransson
    Helena Mellander
    Birgitta Ramgren
    Henrik Andersson
    Francesco Arena
    Kristina Ydström
    Teresa Ullberg
    Johan Wassélius
    Neuroradiology, 2023, 65 : 1333 - 1342
  • [33] Image quality of spectral brain computed tomography angiography using halved dose of iodine contrast medium
    Fransson, Veronica
    Mellander, Helena
    Ramgren, Birgitta
    Andersson, Henrik
    Arena, Francesco
    Ydstroem, Kristina
    Ullberg, Teresa
    Wasselius, Johan
    NEURORADIOLOGY, 2023, 65 (09) : 1333 - 1342
  • [34] Image quality and radiation exposure with low-contrast-dose computed tomography angiography of the lower extremities
    Assi, Abed Al Nasser
    POLISH JOURNAL OF RADIOLOGY, 2020, 85 : E169 - E173
  • [35] Effects of different tube potentials and iodine concentrations on image enhancement, contrast-to-noise ratio and noise in micro-CT images: a phantom study
    Razak, Hairil Rashmizal Abdul
    Rahmat, Said Mohd Shaffiq Said
    Saad, Wan Mazlina Md
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2013, 3 (05) : 256 - 261
  • [36] Application of deep-learning reconstruction algorithm for enhanced CT scan of upper abdomen under different radiation doses: focus on noise, contrast-to-noise ratio and image quality
    Yanrong Xie
    Yuan-Cheng Wang
    Shan Huang
    Shenghong Ju
    Chinese Journal of Academic Radiology, 2022, 5 : 107 - 121
  • [37] Application of deep-learning reconstruction algorithm for enhanced CT scan of upper abdomen under different radiation doses: focus on noise, contrast-to-noise ratio and image quality
    Xie, Yanrong
    Wang, Yuan-Cheng
    Huang, Shan
    Ju, Shenghong
    CHINESE JOURNAL OF ACADEMIC RADIOLOGY, 2022, 5 (02) : 107 - 121
  • [38] Dual-energy computed tomography pulmonary angiography with ultra-low dose contrast administration: Comparison of image quality with standard computed tomography pulmonary angiography
    Celtikci, Pinar
    Hekimoglu, Koray
    Kahraman, Gokhan
    Haberal, Kemal Murat
    Kilic, Dalokay
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 30 (04): : 549 - 556
  • [39] Evaluation of image quality for stent image with different dilution ratio of contrast agent in self-production vessel model on angiographic X-ray computed tomography (CT)
    Choi, Hye Ran
    Choi, Won Ho
    Lee, Seung Chan
    Ha, Yun Kyung
    Kang, Seong Hyeon
    Kim, Dae Ho
    Lee, Youngjin
    OPTIK, 2017, 143 : 180 - 187
  • [40] The investigation of dose and image quality of chest computed tomography using different combinations of noise index and adaptive statistic iterative reconstruction level
    Sookpeng, Supawitoo
    Martin, Colin J.
    Butdee, Chitsanupong