Cementless acetabular revision with the Harris-Galante Porous prosthesis - Results after a minimum of ten years of follow-up

被引:46
|
作者
Hallstrom, BR
Golladay, GJ
Vittetoe, DA
Harris, WH
机构
[1] Massachusetts Gen Hosp, Dept Orthopaed Surg, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
来源
关键词
D O I
10.2106/00004623-200405000-00018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Revisions of the acetabular component of a total hip arthroplasty have a higher rate of complications, particularly loosening and dislocation, than do primary procedures. The purpose of this study, in which the results of a consecutive series of revisions performed with the Harris-Galante Porous acetabular component by a single surgeon were evaluated at an average of twelve years, was to quantify the complications and outcomes of acetabular revision. Methods: Clinical and radiographic results were evaluated to assess loosening, lysis, radiolucencies, and trochanteric union in 188 hips (170 patients) treated between 1984 and 1990. One hundred and twenty-two hips in 110 patients were followed for at least ten years, which was required for inclusion in the study. Thirty-one patients (thirty-six hips) died less than ten years postoperatively, and twenty-nine patients (thirty hips) were lost to or refused to return for follow-up. Results: The average Harris hip score was 78 points at an average of 12.5 years after revisioi, which was a 29-point improvement compared with the preoperative score. The rate of repeat revision because of aseptic loosening of the acetabular shell was 4% (five of 122). The rate of repeat revision of the shell for any reason was 15% (eighteen of 122). Eight unrevised sockets were loose radiographically, for a total rate of aseptic loosening of 11% (thirteen of 122). Conclusions: This study demonstrated that most acetabular revisions with this cementless hemispherical socket were successful. Few structural grafts and no cages were used. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1007 / 1011
页数:5
相关论文
共 50 条
  • [1] The Harris-Galante porous acetabular component at intermediate follow-up
    D'Lima, DD
    Yashar, AA
    Venn-Watson, EJ
    Colwell, CW
    Walker, RH
    [J]. ORTHOPEDICS, 2001, 24 (08) : 747 - 751
  • [2] Isolated acetabular revision with use of the Harris-Galante cementless component - Study with intermediate-term follow-up
    Jamali, AA
    Dungy, DS
    Mark, A
    Schule, S
    Harris, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08): : 1690 - 1697
  • [3] Complications with the Harris-Galante porous-coated acetabular component after a mean follow-up of 7 years
    Lecoq, C
    Rochwerger, A
    Curvale, G
    Groulier, P
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1999, 85 (07): : 689 - 697
  • [4] RESULTS OF THE HARRIS-GALANTE CEMENTLESS HIP-PROSTHESIS
    KIM, YH
    KIM, VEM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (01): : 83 - 87
  • [5] REVISION OF THE ACETABULAR COMPONENT WITH AN UNCEMENTED HARRIS-GALANTE POROUS-COATED PROSTHESIS
    TANZER, M
    DRUCKER, D
    JASTY, M
    MCDONALD, M
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07): : 987 - 994
  • [6] Fifteen-Year to Twenty-Year Results of Cementless Harris-Galante Porous Femoral and Harris-Galante Porous I and II Acetabular Components
    Anseth, Scott D.
    Pulido, Pamela A.
    Adelson, Wendy S.
    Patil, Shantanu
    Sandwell, Julie C.
    Colwell, Clifford W., Jr.
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (05): : 687 - 691
  • [7] The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study
    Clohisy, JC
    Harris, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01): : 66 - 73
  • [8] Revision of a total hip arthroplasty with a Harris-Galante porous-coated acetabular component inserted without cement - A follow-up note on the results at five to twelve years
    Lachiewicz, PF
    Poon, ED
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07): : 980 - 984
  • [9] RESULTS OF CEMENTLESS REVISIONS OF TOTAL HIP ARTHROPLASTIES USING THE HARRIS-GALANTE PROSTHESIS
    HARRIS, WH
    KRUSHELL, RJ
    GALANTE, JO
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (235) : 120 - 126
  • [10] The Harris-Galante total hip arthroplasty - A minimum 8-year follow-up study
    Cruz-Pardos, A
    Garcia-Cimbrelo, E
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (05): : 586 - 597