Cementless acetabular revision with the Harris-Galante Porous prosthesis - Results after a minimum of ten years of follow-up

被引:46
|
作者
Hallstrom, BR
Golladay, GJ
Vittetoe, DA
Harris, WH
机构
[1] Massachusetts Gen Hosp, Dept Orthopaed Surg, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02115 USA
来源
关键词
D O I
10.2106/00004623-200405000-00018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Revisions of the acetabular component of a total hip arthroplasty have a higher rate of complications, particularly loosening and dislocation, than do primary procedures. The purpose of this study, in which the results of a consecutive series of revisions performed with the Harris-Galante Porous acetabular component by a single surgeon were evaluated at an average of twelve years, was to quantify the complications and outcomes of acetabular revision. Methods: Clinical and radiographic results were evaluated to assess loosening, lysis, radiolucencies, and trochanteric union in 188 hips (170 patients) treated between 1984 and 1990. One hundred and twenty-two hips in 110 patients were followed for at least ten years, which was required for inclusion in the study. Thirty-one patients (thirty-six hips) died less than ten years postoperatively, and twenty-nine patients (thirty hips) were lost to or refused to return for follow-up. Results: The average Harris hip score was 78 points at an average of 12.5 years after revisioi, which was a 29-point improvement compared with the preoperative score. The rate of repeat revision because of aseptic loosening of the acetabular shell was 4% (five of 122). The rate of repeat revision of the shell for any reason was 15% (eighteen of 122). Eight unrevised sockets were loose radiographically, for a total rate of aseptic loosening of 11% (thirteen of 122). Conclusions: This study demonstrated that most acetabular revisions with this cementless hemispherical socket were successful. Few structural grafts and no cages were used. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1007 / 1011
页数:5
相关论文
共 50 条
  • [41] Isolated acetabular revision after total hip arthroplasty: results at 5-9 years of follow-up
    Chen, XD
    Waddell, JP
    Morton, J
    Schemitsch, EH
    [J]. INTERNATIONAL ORTHOPAEDICS, 2005, 29 (05) : 277 - 280
  • [42] The Talar Body Prosthesis: Results at Ten to Thirty-six Years of Follow-up
    Harnroongroj, Thos
    Harnroongroj, Thossart
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (14): : 1211 - 1218
  • [43] Cementless Revision for Infected Hip Arthroplasty: an 8.6 Years Follow-up
    Li, Peng
    Hou, Ming
    Zhu, Zhi-qi
    Shi, Zhan-jun
    [J]. ORTHOPAEDIC SURGERY, 2015, 7 (01) : 37 - 42
  • [44] The Durom acetabular component. A concise follow-up of early revision rates at a minimum of 2 years
    Hutt, Jonathan
    Dodd, Matthew
    Briffa, Nikolai
    Bourke, Henry
    Hazlerigg, Alexandra
    Ward, David
    [J]. HIP INTERNATIONAL, 2012, 22 (05) : 562 - 565
  • [45] Rotational acetabular osteotomy for acetabular dysplasia - A follow-up for more than ten years
    Nozawa, M
    Shitoto, K
    Matsuda, K
    Maezawa, K
    Kurosawa, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B : 59 - 65
  • [46] Arthroplasty of the proximal interphalangeal joint with the TACTYS® prosthesis: Preliminary results after a minimum follow-up of 2 years
    Athlani, L.
    Gaisne, E.
    Bellemere, P.
    [J]. HAND SURGERY & REHABILITATION, 2016, 35 (03): : 168 - 178
  • [47] Acetabular reinforcement ring with hook for complex acetabular revision in total hip arthroplasty. A minimum follow-up of 10 years
    Siebenrock, KA
    Trochsler, M
    Sadri, H
    Ganz, R
    [J]. ORTHOPADE, 2001, 30 (05): : 273 - +
  • [48] Poor outcome of the PCA and Harris-Galante hip prostheses -: Randomized study of 171 arthroplasties with 9-year follow-up
    Thanner, J
    Kärrholm, J
    Malchau, H
    Herberts, P
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (02): : 155 - 162
  • [49] The porous-coated anatomic total hip prosthesis, inserted without cement - A prospective study with a minimum of ten years of follow-up
    Xenos, JS
    Callaghan, JJ
    Heekin, RD
    Hopkinson, WJ
    Savory, CG
    Moore, MS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01): : 74 - 82
  • [50] Cementless Acetabular Fixation in Patients 50 Years and Younger at 10 to 18 Years of Follow-Up
    Teusink, Matthew J.
    Callaghan, John J.
    Warth, Lucian C.
    Goetz, Devon D.
    Pedersen, Douglas R.
    Johnston, Richard C.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (07): : 1316 - 1323