Complications with the Harris-Galante porous-coated acetabular component after a mean follow-up of 7 years

被引:0
|
作者
Lecoq, C [1 ]
Rochwerger, A [1 ]
Curvale, G [1 ]
Groulier, P [1 ]
机构
[1] Hop Concept, Serv Chirurg Orthoped & Traumatol, F-13385 Marseille 05, France
关键词
Harris-Galante; acetabular component; wear; total hip arthroplasty; complications;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Material and methods Hundred and twelve hip were studied in 107 patients with a mean follow-up of 7 years (range, 6-9 years). Harris and Poster-Merle d'Aubigne clinical hip scores were used. The prosthetic components were evaluated using radiographic criteria. Results The mean Harris score was 91 (range, 34-100). The incidence of proximal pain was 3,7 p.100 in anterior area and also 3,7 p.100 in posterior area. Radiolucent lines were present in one acetabular zone in 28,5 p.100 of cases, in two zones in 26 p.100, in all three zones in 5,5 p.100. No statistical significant correlation was identified relating pain and radiolucent lines. The mean rate of linear wear per year was 0,1 millimeter. A statistically significant correlation was identified relating a linear wear per year above 0,12 millimeter and the presence of radiolucent lines. A major polyethylene wear (from 2,75 to 3,5 millimeters) was found in 5 cases. One of them had an acetabular osteolysis. One acetabular liner was found unstable in the metal shell during a hip revision for a major wear. Two patients had a dislocation of the liner in the metal-back. Eight hips needed a revision surgery, always for a failure of the polyethylene liner, never for a loosening between the socket and the acetabulum. Discussion and conclusion The acetabular component bone fixation of this Harris-Galante prosthesis appears optimum. The polyethylene wear and the unstability between the polyethylene cup and the metal socket need to stop using this component. The fixation between his two parts have to be improved.
引用
收藏
页码:689 / 697
页数:9
相关论文
共 50 条
  • [1] The Harris-Galante porous acetabular component at intermediate follow-up
    D'Lima, DD
    Yashar, AA
    Venn-Watson, EJ
    Colwell, CW
    Walker, RH
    [J]. ORTHOPEDICS, 2001, 24 (08) : 747 - 751
  • [2] REVISION OF THE ACETABULAR COMPONENT WITH AN UNCEMENTED HARRIS-GALANTE POROUS-COATED PROSTHESIS
    TANZER, M
    DRUCKER, D
    JASTY, M
    MCDONALD, M
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07): : 987 - 994
  • [3] The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study
    Clohisy, JC
    Harris, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01): : 66 - 73
  • [4] Revision of a total hip arthroplasty with a Harris-Galante porous-coated acetabular component inserted without cement - A follow-up note on the results at five to twelve years
    Lachiewicz, PF
    Poon, ED
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07): : 980 - 984
  • [5] Cementless acetabular revision with the Harris-Galante Porous prosthesis - Results after a minimum of ten years of follow-up
    Hallstrom, BR
    Golladay, GJ
    Vittetoe, DA
    Harris, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05): : 1007 - 1011
  • [6] THE HARRIS-GALANTE POROUS-COATED ACETABULAR COMPONENT WITH SCREW FIXATION - RADIOGRAPHIC ANALYSIS OF 83 PRIMARY HIP REPLACEMENTS AT A MINIMUM OF 5 YEARS
    SCHMALZRIED, TP
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (08): : 1130 - 1139
  • [7] Isolated acetabular revision with use of the Harris-Galante cementless component - Study with intermediate-term follow-up
    Jamali, AA
    Dungy, DS
    Mark, A
    Schule, S
    Harris, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08): : 1690 - 1697
  • [8] BEAD LOOSENING FROM A POROUS-COATED ACETABULAR COMPONENT - A FOLLOW-UP NOTE
    MALONEY, WJ
    DAVEY, JR
    HARRIS, WH
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (281) : 112 - 114
  • [9] The Harris-Galante porous-coated, hemispherical, polyethylene-lined acetabular component in patients under 50 years of age A 12- TO 16-YEAR REVIEW
    Utting, M. R.
    Raghuvanshi, M.
    Amirfeyz, R.
    Blom, A. W.
    Learmonth, I. D.
    Bannister, G. C.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (11): : 1422 - 1427
  • [10] Clinical and radiographic evaluation of the Harris-Galante cup - Incidence of wear and osteolysis at 7 to 9 years follow-up
    Soto, MO
    Rodriguez, JA
    Ranawat, CS
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (02): : 139 - 145