The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study

被引:130
|
作者
Clohisy, JC
Harris, WH
机构
[1] Massachusetts Gen Hosp, Orthopaed Biomech Lab, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Orthopaed Surg, Hip & Implant Unit, Boston, MA 02114 USA
来源
关键词
D O I
10.2106/00004623-199901000-00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Two hundred and thirty-seven consecutive primary acetabular reconstructions were performed, in 213 patients, with use of a Harris-Galante porous-coated acetabular component with screw fixation between January 1984 and December 1987. Twenty-four patients (twenty-seven hips) died before a minimum duration of follow-up of eighty-four months, five patients (five hips) were too ill to return for a detailed follow-up examination at the time of the study, four patients (four hips) refused clinical and radiographic follow-up (but one of these patients had more than eighty-four months of follow-up for one side of a bilateral total hip replacement), two patients (two hips) were lost to follow-np, and two patients (two hips) refused radiographic follow-up but had adequate clinical follow-up. In addition, one patient who had had a bilateral total hip replacement had a resection arthroplasty on one side because of a late infection 115 months after the index procedure. Thus, 196 hips (83 per cent) in 177 patients were available for radiographic and clinical review after an average duration of follow-up of 122 months (range, eighty-four to 155 months). The average age of these 177 patients at the time of the operation was fifty-nine years (range, twenty-three to eighty-seven years). Eight well fixed acetabular shells (4 percent) were revised: three were revised because of dissociation of the liner in association with fractures of the tines, three were revised during revision of the femoral component, and two were revised because of retroacetabular osteolysis. In eight other hips, the acetabular liner,vas exchanged during revision of a loose femoral component. No acetabular component migrated, was classified as radiographically loose, or was revised because of aseptic loosening. There was no evidence of fragmentation or disruption of the titanium porous mesh of any cup. One of 528 screws broke. There were no complications associated with the insertion of the acetabular fixation screws. Osteolytic lesions were identified adjacent to nine (5 percent) of the 188 acetabular components that were in place at the time of the most recent examination. One hip, which had discontinuous osteolytic lesions in all three acetabular zones, was treated with bone-grafting around the well fixed acetabular component. Eight hips had a discontinuous radiolucent line that was 1.0 millimeter wide or less in all three zones and another two had a continuous radiolucent line that was 0.5 millimeter wide in all three zones. The average Harris hip score for the 188 hips (169 patients) that did not have revision of the acetabular shell improved from 47 points (range, 22 to 71 points) preoperatively to 89 points (range, 35 to 100 points) at the time of the latest examination. One hundred and thirty-four hips had an excellent result; twenty-six, a good result; nineteen, a fair result; and nine, a poor result. All nine hips that had a poor result were in patients who had of her factors, unrelated to the acetabular component, that contributed to the low Harris hip score. In the present study the Harris-Galante porous-coated acetabular component continued to provide excellent fixation and clinical results for most patients at an average of approximately ten years after the operation.
引用
收藏
页码:66 / 73
页数:8
相关论文
共 50 条
  • [1] Complications with the Harris-Galante porous-coated acetabular component after a mean follow-up of 7 years
    Lecoq, C
    Rochwerger, A
    Curvale, G
    Groulier, P
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1999, 85 (07): : 689 - 697
  • [2] The Harris-Galante porous acetabular component at intermediate follow-up
    D'Lima, DD
    Yashar, AA
    Venn-Watson, EJ
    Colwell, CW
    Walker, RH
    [J]. ORTHOPEDICS, 2001, 24 (08) : 747 - 751
  • [3] REVISION OF THE ACETABULAR COMPONENT WITH AN UNCEMENTED HARRIS-GALANTE POROUS-COATED PROSTHESIS
    TANZER, M
    DRUCKER, D
    JASTY, M
    MCDONALD, M
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07): : 987 - 994
  • [4] THE HARRIS-GALANTE POROUS-COATED ACETABULAR COMPONENT WITH SCREW FIXATION - RADIOGRAPHIC ANALYSIS OF 83 PRIMARY HIP REPLACEMENTS AT A MINIMUM OF 5 YEARS
    SCHMALZRIED, TP
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (08): : 1130 - 1139
  • [5] Porous-coated acetabular components with screw fixation - Five to ten-year results
    Latimer, HA
    Lachiewicz, PF
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (07): : 975 - 981
  • [6] Revision of a total hip arthroplasty with a Harris-Galante porous-coated acetabular component inserted without cement - A follow-up note on the results at five to twelve years
    Lachiewicz, PF
    Poon, ED
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07): : 980 - 984
  • [7] Cementless acetabular revision with the Harris-Galante Porous prosthesis - Results after a minimum of ten years of follow-up
    Hallstrom, BR
    Golladay, GJ
    Vittetoe, DA
    Harris, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05): : 1007 - 1011
  • [8] Ten-year results of a press-fit, porous-coated acetabular component
    Grobler, GP
    Learmonth, ID
    Bernstein, BP
    Dower, BJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (06): : 786 - 789
  • [9] Isolated acetabular revision with use of the Harris-Galante cementless component - Study with intermediate-term follow-up
    Jamali, AA
    Dungy, DS
    Mark, A
    Schule, S
    Harris, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08): : 1690 - 1697
  • [10] A ten-year follow-up of the Reflection cementless acetabular component
    Civinini, R.
    D'Arienzo, M.
    Innocenti, M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (05): : 570 - 573