The Harris-Galante porous-coated, hemispherical, polyethylene-lined acetabular component in patients under 50 years of age A 12- TO 16-YEAR REVIEW

被引:35
|
作者
Utting, M. R.
Raghuvanshi, M.
Amirfeyz, R. [1 ]
Blom, A. W. [1 ]
Learmonth, I. D. [1 ]
Bannister, G. C. [1 ]
机构
[1] Southmead Hosp, Avon Orthopaed Ctr, Bristol BS10 5NB, Avon, England
来源
关键词
D O I
10.1302/0301-620X.90B11.20892
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We have reviewed 70 Harris-Galante uncemented acetabular components implanted as hybrid hip replacements with cemented stems between 1991 and 1995 in 53 patients whose mean age was 40 years (19 to 49). The mean follow-up was for 13.6 years (12 to 16) with no loss to follow-up. We assessed the patients both clinically and radiologically. The mean Oxford hip score was 20 (12 to 46) and the mean Harris hip score 81 (37 to 100) at the final review. Radiologically, 27 hips (39%) had femoral osteolysis, 13 (19%) acetabular osteolysis, and 31 (44%) radiolucent lines around the acetabular component. Kaplan-Meier survival curves were constructed for the outcomes of revision of the acetabular component, revision of the component and polyethylene liner, and impending revision for progressive osteolysis. The cumulative survival for revision of the acetabular component was 94% (95% confidence interval 88.4 to 99.7), for the component and liner 84% (95% confidence interval 74.5 to 93.5) and for impending revision 55.3% (95% confidence interval 40.6 to 70) at 16 years. Uncemented acetabular components with polyethylene liners undergo silent lysis and merit regular long-term radiological review.
引用
收藏
页码:1422 / 1427
页数:6
相关论文
共 4 条
  • [1] Complications with the Harris-Galante porous-coated acetabular component after a mean follow-up of 7 years
    Lecoq, C
    Rochwerger, A
    Curvale, G
    Groulier, P
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1999, 85 (07): : 689 - 697
  • [2] The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study
    Clohisy, JC
    Harris, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01): : 66 - 73
  • [3] THE HARRIS-GALANTE POROUS-COATED ACETABULAR COMPONENT WITH SCREW FIXATION - RADIOGRAPHIC ANALYSIS OF 83 PRIMARY HIP REPLACEMENTS AT A MINIMUM OF 5 YEARS
    SCHMALZRIED, TP
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (08): : 1130 - 1139
  • [4] Revision of a total hip arthroplasty with a Harris-Galante porous-coated acetabular component inserted without cement - A follow-up note on the results at five to twelve years
    Lachiewicz, PF
    Poon, ED
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (07): : 980 - 984