Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver

被引:16
|
作者
Kim, Yeun-Yoon [1 ]
Kim, Myeong-Jin [1 ]
Gho, Sung-Min [2 ]
Seo, Nieun [1 ]
机构
[1] Yonsei Univ, Severance Hosp, Dept Radiol, Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
[2] GE Healthcare, MR Collaborat & Dev, 416 Hangang Daero, Seoul 04637, South Korea
关键词
Diagnostic techniques and procedures; Magnetic resonance imaging; Comparative study; Artefacts; Signal-to-noise ratio; LESION DETECTION; MRI; EPI; ARTIFACTS; IMAGES; DWI;
D O I
10.1016/j.ejrad.2020.109292
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare multiplexed sensitivity encoding (MUSE) and conventional diffusion-weighted magnetic resonance imaging (cDWI) techniques in liver MRI. Methods: Fifty-nine patients who underwent both two-shot echo-planar DWI using MUSE and single-shot echoplanar cDWI at a 3.0-T MRI system were included. Qualitative parameters were independently evaluated by three radiologists, and quantitative parameters were calculated on the basis of region of interest measurements. Receiver operating characteristic curve analysis and McNemar's test were used to compare solid lesion characterization results and lesion detectability, respectively. Results: All reviewers found less image noise, sharper liver contours, milder susceptibility artifacts, and better lesion conspicuity in MUSE-DWI than in cDWI (reader average mean, 4.1-4.5 vs. 3.5-4.0; p < 0.05). The signalto-noise ratio (SNR) of the liver was significantly higher in MUSE-DWI than in cDWI (right lobe: mean, 9.39 vs. 8.10, p < 0.001; left lobe: mean, 8.34 vs. 7.19, p < 0.001), while the SNR of the lesion (mean, 23.72 vs. 23.88, p = 0.911) and lesion-to-liver contrast-to-noise ratio (mean, 14.65 vs. 15.41, p = 0.527) were comparable between MUSE-DWI and cDWI. Solid lesion characterization results were comparably accurate between MUSE-DWI and cDWI (reader average area under the receiver operating characteristic curve, 0.985 vs. 0.986, p = 0.480). The detectability of lesions was better in MUSE-DWI than in cDWI (reader consensus, 83.7 % [41/49] vs. 67.3 % [33/49], p = 0.021). Conclusion: MUSE-DWI can provide multi-shot liver DWI with less noise, fewer distortions, improved SNR of the liver, and better lesion detectability.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients
    T. Ichikawa
    H. Haradome
    J. Hachiya
    T. Nitatori
    T. Araki
    Abdominal Imaging, 1999, 24 : 456 - 461
  • [32] Colorectal hepatic metastases: quantitative measurements using single-shot echo-planar diffusion-weighted MR imaging
    D. M. Koh
    E. Scurr
    D. J. Collins
    A. Pirgon
    B. Kanber
    N. Karanjia
    G. Brown
    M. O. Leach
    J. E. Husband
    European Radiology, 2006, 16 : 1898 - 1905
  • [33] Colorectal hepatic metastases: quantitative measurements using single-shot echo-planar diffusion-weighted MR imaging
    Koh, D. M.
    Scurr, E.
    Collins, D. J.
    Pirgon, A.
    Kanber, B.
    Karanjia, N.
    Brown, G.
    Leach, M. O.
    Husband, J. E.
    EUROPEAN RADIOLOGY, 2006, 16 (09) : 1898 - 1905
  • [34] Assessment of Mediastinal Tumors With Diffusion-Weighted Single-Shot Echo-Planar MRI
    Razek, Ahmed Abdel
    Elmorsy, Ahmed
    Elshafey, Mohsen
    Elhadedy, Tamer
    Hamza, Osama
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 535 - 540
  • [35] Single-shot diffusion-weighted echo-planar imaging of normal and cirrhotic livers using a phased-array multicoil
    Amano, Y
    Kumazaki, T
    Ishihara, M
    ACTA RADIOLOGICA, 1998, 39 (04) : 440 - 442
  • [36] Single-shot velocity mapping by rewinding of velocity encoding with Echo-Planar Imaging
    Serial, Maria R.
    Silletta, Emilia, V
    Perlo, Josefina
    Giovacchini, Juan P.
    Velasco, Manuel, I
    Bluemich, Bernhard
    Danieli, Ernesto D.
    Casanova, Federico
    Acosta, Rodolfo H.
    JOURNAL OF MAGNETIC RESONANCE, 2019, 307
  • [37] Diffusion-weighted single shot echo planar imaging of colorectal cancer using a sensitivity-encoding technique
    Nasu, K
    Kuroki, Y
    Kuroki, S
    Murakami, K
    Nawano, S
    Moriyama, N
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2004, 34 (10) : 620 - 626
  • [38] Characterization of focal liver lesions with diffusion-weighted echo-planar imaging
    Laghi, A
    Pavone, P
    Catalano, C
    Panebianco, V
    Fabiano, S
    Baeli, I
    Passariello, R
    HEPATOLOGY, 1999, 30 (04) : 282A - 282A
  • [39] Diffusion-Weighted Imaging with Dual-Echo Echo-Planar Imaging for Better Sensitivity to Acute Stroke
    Holdsworth, S. J.
    Yeom, K. W.
    Antonucci, M. U.
    Andre, J. B.
    Rosenberg, J.
    Aksoy, M.
    Straka, M.
    Fischbein, N. J.
    Bammer, R.
    Moseley, M. E.
    Zaharchuk, G.
    Skare, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (07) : 1293 - 1302
  • [40] Comparison of single-shot echo-planar and line scan protocols for diffusion tensor-imaging
    Kubicki, M
    Maier, SE
    Westin, CF
    Mamata, H
    Ersner-Hershfield, H
    Estepar, R
    Kikinis, R
    Jolesz, FA
    McCarley, RW
    Shenton, ME
    ACADEMIC RADIOLOGY, 2004, 11 (02) : 224 - 232