Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study

被引:19
|
作者
Schoennagel, Bjoern P. [1 ]
Remus, Chressen C. [1 ]
Yamamura, Jin [1 ]
Kording, Fabian [1 ]
de Sousa, Manuela Tavares [2 ]
Hecher, Kurt [2 ]
Fischer, Roland [3 ,4 ]
Ueberle, Friedrich [5 ]
Boehme, Matthias [1 ]
Adam, Gerhard [1 ]
Kooijman, Hendrik [6 ]
Wedegaertner, Ulrike [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Obstet & Fetal Med, D-20246 Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Pediat Hematol & Oncol, D-20246 Hamburg, Germany
[4] Childrens Hosp & Res Ctr Oakland, Oakland, CA USA
[5] Hamburg Univ Appl Sci, Hamburg, Germany
[6] Philips Med Syst, Hamburg, Germany
关键词
Magnetic resonance imaging; Cardiac triggering; Fetal blood flow; Flow velocimetry; Fetal sheep; INTRAUTERINE GROWTH RESTRICTION; PRENATAL-DIAGNOSIS; DESCENDING AORTA; VENOUS DOPPLER; ANIMAL-MODEL; VELOCITY; VALIDATION; ARTERY; QUANTIFICATION; CIRCULATION;
D O I
10.1007/s10334-013-0397-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present the first study demonstrating the feasibility of antenatal blood flow velocimetry performing ECG triggered phase-contrast (PC)-MRI in the fetal aorta by using a newly developed Doppler ultrasound trigger. Five pregnant sheep carrying singleton fetuses (gestational age 121 days) were anesthetized to undergo fetal 2D PC-MRI in the fetal descending aorta (1.5 T) using a newly developed MR-compatible Doppler ultrasound trigger for fetal cardiac triggering. Inter-operator variability was assessed for PC-MR measurements and reproducibility was tested by repeated scans in one fetus. Inter-modality comparison was performed by Doppler ultrasound velocimetry. Fetal cardiac triggering was possible in all examinations. PC-MR velocimetry revealed a mean inter-operator variability of 3 +/- A 5 %. Average peak systolic flow velocities of 62.5 +/- A 4.4 cm/s were in good agreement with Doppler ultrasound measurements of 62.0 +/- A 9.2 cm/s (p (Lord's U test) a parts per thousand << 0.05). Fetal PC-MR velocimetry was successfully performed using the newly developed MR-compatible Doppler ultrasound trigger for intrauterine fetal cardiac triggering, demonstrating high inter-operator and inter-modality agreement. This new method has the high potential for alternative assessment of hemodynamic decompensation of the fetal circulation.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [21] Accelerated Phase-Contrast MR Imaging: Comparison of k-t BLAST With SENSE and Doppler Ultrasound for Velocity and Flow Measurements in the Aorta
    Stadlbauer, Andreas
    van der Riet, Wilma
    Globits, Sebastian
    Crelier, Gerard
    Salomonowitz, Erich
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (04) : 817 - 824
  • [22] Carotid Artery Flow as Determined by Real-Time Phase-Contrast Flow Mri and Neurovascular Ultrasound: a Comparative Study of Healthy Subjects
    Maier, Ilko
    Hofer, Sabine
    Joseph, Arun A.
    Merboldt, Klaus-Dietmar
    Tan, Zhengguo
    Schregel, Katharina
    Knauth, Michael
    Bahr, Mathias
    Psychogios, Marios-Nikos
    Liman, Jan
    Frahm, Jens
    STROKE, 2018, 49
  • [23] Carotid artery flow as determined by real-time phase-contrast flow MRI and neurovascular ultrasound: A comparative study of healthy subjects
    Maier, Ilko L.
    Hofer, Sabine
    Joseph, Arun A.
    Merboldt, K. Dietmar
    Tan, Zhengguo
    Schregel, Katharina
    Knauth, Michael
    Baehr, Mathias
    Psychogios, Marios-Nikos
    Liman, Jan
    Frahm, Jens
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 106 : 38 - 45
  • [24] Optimized analysis of blood flow and wall shear stress in the common carotid artery of rat model by phase-contrast MRI
    Peng, Shin-Lei
    Shih, Cheng-Ting
    Huang, Chiun-Wei
    Chiu, Shao-Chieh
    Shen, Wu-Chung
    SCIENTIFIC REPORTS, 2017, 7
  • [25] Optimized analysis of blood flow and wall shear stress in the common carotid artery of rat model by phase-contrast MRI
    Shin-Lei Peng
    Cheng-Ting Shih
    Chiun-Wei Huang
    Shao-Chieh Chiu
    Wu-Chung Shen
    Scientific Reports, 7
  • [26] Evaluation of uterine blood flow: a new method using contrast-enhanced ultrasound
    Makino, Shintaro
    Hirai, Chihiro
    Itakura, Atsuo
    Takeda, Satoru
    Yoshikawa, Hideki
    Li, Zisheng
    Kawabata, Ken-ichi
    Tanaka, Hiroki
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2015, 191 : 143 - 144
  • [27] Assessing arterial blood flow and vessel area variations using real-time zonal phase-contrast MRI
    Oelhafen, M
    Schwitter, J
    Kozerke, S
    Luechinger, R
    Boesiger, P
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (03) : 422 - 429
  • [28] Comparison of Cartesian, UTE radial, and Spiral Phase-Contrast MRI in Measurement of Blood Flow in Extracranial Carotid Arteries: Normal Subjects
    Negahdar, M. J.
    Kadbi, M. O.
    Tavakoli, Vahid
    Heidenreich, Jens
    Amini, Amir A.
    MEDICAL IMAGING 2013: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2013, 8672
  • [29] Automated measurement and classification of pulmonary blood-flow velocity patterns using phase-contrast MRI and correlation analysis
    van Amerom, Joshua F. P.
    Kellenberger, Christian J.
    Yoo, Shi-Joon
    Macgowan, Christopher K.
    MAGNETIC RESONANCE IMAGING, 2009, 27 (01) : 38 - 47
  • [30] Quantification of Hepatic Blood Flow Using a High-Resolution Phase-Contrast MRI Sequence With Compressed Sensing Acceleration
    Dyvorne, Hadrien A.
    Knight-Greenfield, Ashley
    Besa, Cecilia
    Cooper, Nancy
    Garcia-Flores, Julio
    Schiano, Thomas D.
    Markl, Michael
    Taouli, Bachir
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : 510 - 518