Fetal blood flow velocimetry by phase-contrast MRI using a new triggering method and comparison with Doppler ultrasound in a sheep model: a pilot study

被引:19
|
作者
Schoennagel, Bjoern P. [1 ]
Remus, Chressen C. [1 ]
Yamamura, Jin [1 ]
Kording, Fabian [1 ]
de Sousa, Manuela Tavares [2 ]
Hecher, Kurt [2 ]
Fischer, Roland [3 ,4 ]
Ueberle, Friedrich [5 ]
Boehme, Matthias [1 ]
Adam, Gerhard [1 ]
Kooijman, Hendrik [6 ]
Wedegaertner, Ulrike [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Obstet & Fetal Med, D-20246 Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Pediat Hematol & Oncol, D-20246 Hamburg, Germany
[4] Childrens Hosp & Res Ctr Oakland, Oakland, CA USA
[5] Hamburg Univ Appl Sci, Hamburg, Germany
[6] Philips Med Syst, Hamburg, Germany
关键词
Magnetic resonance imaging; Cardiac triggering; Fetal blood flow; Flow velocimetry; Fetal sheep; INTRAUTERINE GROWTH RESTRICTION; PRENATAL-DIAGNOSIS; DESCENDING AORTA; VENOUS DOPPLER; ANIMAL-MODEL; VELOCITY; VALIDATION; ARTERY; QUANTIFICATION; CIRCULATION;
D O I
10.1007/s10334-013-0397-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present the first study demonstrating the feasibility of antenatal blood flow velocimetry performing ECG triggered phase-contrast (PC)-MRI in the fetal aorta by using a newly developed Doppler ultrasound trigger. Five pregnant sheep carrying singleton fetuses (gestational age 121 days) were anesthetized to undergo fetal 2D PC-MRI in the fetal descending aorta (1.5 T) using a newly developed MR-compatible Doppler ultrasound trigger for fetal cardiac triggering. Inter-operator variability was assessed for PC-MR measurements and reproducibility was tested by repeated scans in one fetus. Inter-modality comparison was performed by Doppler ultrasound velocimetry. Fetal cardiac triggering was possible in all examinations. PC-MR velocimetry revealed a mean inter-operator variability of 3 +/- A 5 %. Average peak systolic flow velocities of 62.5 +/- A 4.4 cm/s were in good agreement with Doppler ultrasound measurements of 62.0 +/- A 9.2 cm/s (p (Lord's U test) a parts per thousand << 0.05). Fetal PC-MR velocimetry was successfully performed using the newly developed MR-compatible Doppler ultrasound trigger for intrauterine fetal cardiac triggering, demonstrating high inter-operator and inter-modality agreement. This new method has the high potential for alternative assessment of hemodynamic decompensation of the fetal circulation.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [41] Evaluation of aortic valve stenosis from Phase-Contrast Magnetic Resonance data using a new automated segmentation and analysis method: Comparison against Doppler Echocardiography
    Defrance C.
    Bollache E.
    Kachenoura N.
    Bruguière E.
    Redheuil A.
    Diebold B.
    Perdrix L.
    Mousseaux E.
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [42] Blood-flow volume quantification in internal carotid and vertebral arteries:: Comparison of 3 different ultrasound techniques with phase-contrast MR imaging\
    Oktar, SO
    Yücel, C
    Karaosmanoglu, D
    Akkan, K
    Ozdemir, H
    Tokgoz, N
    Tali, T
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (02) : 363 - 369
  • [43] Internal Jugular Vein Blood Flow Reflux Analysis using Ultrasound Doppler Technologies and Phase Contrast Magnetic Resonance Imaging
    Lagana, M. M.
    Preti, G.
    Cecconi, P.
    Forzoni, L.
    D'Onofrio, S.
    Baselli, G.
    Tortoli, P.
    INTERNATIONAL CONFERENCE ON COMPUTER MEDICAL APPLICATIONS (ICCMA' 2013), 2013,
  • [44] Validation of magnetic resonance phase-contrast flow measurements in the main pulmonary artery and aorta using perivascular ultrasound in a large animal model
    Ley, Sebastian
    Unterhinninghofen, Roland
    Ley-Zaporozhan, Julia
    Schenk, Jens-Peter
    Kauczor, Hans-Ulrich
    Szabo, Gabor
    INVESTIGATIVE RADIOLOGY, 2008, 43 (06) : 421 - 426
  • [45] Diagnostic utility of an echo-contrast agent in patients with synovitis using power Doppler ultrasound: a preliminary study with comparison to contrast-enhanced MRI
    Magarelli, N
    Guglielmi, G
    Di Matteo, L
    Tartaro, A
    Mattei, PA
    Bonomo, L
    EUROPEAN RADIOLOGY, 2001, 11 (06) : 1039 - 1046
  • [46] Diagnostic utility of an echo-contrast agent in patients with synovitis using power Doppler ultrasound: a preliminary study with comparison to contrast-enhanced MRI
    Nicola Magarelli
    Giuseppe Guglielmi
    Luigi Di Matteo
    Armando Tartaro
    Peter A. Mattei
    Lorenzo Bonomo
    European Radiology, 2001, 11 : 1039 - 1046
  • [47] Comparison of Global Cerebral Blood Flow Measured by Phase-Contrast Mapping MRI with 15O-H2O Positron Emission Tomography
    Vestergaard, Mark Bitsch
    Lindberg, Ulrich
    Aachmann-Andersen, Niels Jacob
    Lisbjerg, Kristian
    Christensen, Soren Just
    Rasmussen, Peter
    Olsen, Niels Vidiendal
    Law, Ian
    Larsson, Henrik Bo Wiberg
    Henriksen, Otto Molby
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (03) : 692 - 699
  • [48] Blood-flow streams in the fetal inferior vena cava: experimental animal study using ultrasound contrast agent
    Hernandez-Andrade, E.
    Jansson, T.
    Lingman, G.
    Liuba, K.
    Ley, D.
    Marsal, K.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2014, 43 (03) : 353 - 354
  • [49] Analysis of the blood flow of solid ovarian tumours using power Doppler ultrasound:: A new method to predict malignancies?
    Joern, H.
    Deyle, S.
    Schmid-Schoenbein, H.
    Rath, W.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2007, 67 (12) : 1334 - 1338
  • [50] Blood volume flow quantification of the brain-supplying circulation in fibromuscular dysplasia using 2D cine phase-contrast MRI
    Dinter, D. J.
    Buesing, K. A.
    Diehl, S. J.
    Neff, K. W.
    BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (978): : 459 - 467