Study on the Thermal Performance of Office Spaces in the Tropics: A Case Study in Singapore

被引:0
|
作者
Jusuf, Steve Kardinal [1 ]
Ichinose, Masayuki [2 ]
Fukawa, Yuta [2 ]
Sutida, Sattayakorn [3 ]
机构
[1] Singapore Inst Technol, Engn Cluster, Singapore, Singapore
[2] Tokyo Metropolitan Univ, Dept Architecture & Bldg Engn, Tokyo, Japan
[3] Kasetsart Univ, Fac Architecture, Bangkok, Thailand
关键词
Thermal performance; office space; Tropics; Singapore;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Commercial and office buildings often have problems on the aspects of indoor thermal environment and energy performances. The actual performance of these types of buildings, most of the time, are different from the desired performance. A data collection was conducted in an office space of a university building in Singapore as part of the ongoing study, measuring the environmental performance of office buildings across Southeast Asian countries. The objective measurement on the thermal condition shows that most measurement points across office space is at the colder side of the comfort zone. This finding is supported by the survey results where only about 65% of occupants voted for "slightly cool", "neutral" and "slightly warm" and about 22% of occupants showed "cold" related symptoms on their legs, hands and body at the end of working hours. The calculated neutral temperature range was generally from 24 degrees C to 26 degrees C, while the measured room temperature was mostly below 24 degrees C.
引用
收藏
页码:403 / 408
页数:6
相关论文
共 50 条
  • [21] Thermal energy performance in working-spaces from biomorphic models: The tuna case in an office building
    Amaia Zuazua-Ros
    César Martín-Gómez
    Javier Bermejo-Busto
    Marina Vidaurre-Arbizu
    Enrique Baquero
    Rafael Miranda
    Building Simulation, 2016, 9 : 347 - 357
  • [22] Thermal comfort in semi-outdoor spaces within an office building in Shenzhen: A case study in a hot climate region of China
    Cao, Bin
    Luo, Maohui
    Li, Min
    Zhu, Yingxin
    INDOOR AND BUILT ENVIRONMENT, 2018, 27 (10) : 1431 - 1444
  • [23] Thermal performance of a MBT solution -: a case study
    de Almeida, MG
    Bragança, L
    Silva, SM
    Mendonça, P
    XXX IAHS WORLD CONGRESS ON HOUSING, HOUSING CONSTRUCTION: AN INTERDISCIPLINARY TASK, VOLS 1-3, 2002, : 1593 - 1600
  • [24] The modern office case study
    Hill, J.
    Construction Specifier, 2001, 54 (03):
  • [25] Barriers on Establishing Passive Strategies in Office Spaces: A Case Study in a Historic University Building
    Saraiva, Nuno Baia
    Pereira, Luisa Dias
    Gaspar, Adelio Rodrigues
    da Costa, Jose Joaquim
    SUSTAINABILITY, 2021, 13 (08)
  • [26] THE EFFECT OF A PROJECT MANAGEMENT OFFICE ON PROJECT AND ORGANISATIONAL PERFORMANCE: A CASE STUDY
    van der Linde, J.
    Steyn, H.
    SOUTH AFRICAN JOURNAL OF INDUSTRIAL ENGINEERING, 2016, 27 (01): : 151 - 161
  • [27] Assessment of energy and economic performance of office building models: a case study
    Song, X. Y.
    Ye, C. T.
    Li, H. S.
    Wang, X. L.
    Ma, W. B.
    2016 INTERNATIONAL CONFERENCE ON NEW ENERGY AND FUTURE ENERGY SYSTEM (NEFES 2016), 2016, 40
  • [28] Performance validation case study: Federal office building with an integrated facade
    Perepelitza, Mark
    Petterson, Lisa
    Turpin, Kate
    JOURNAL OF BUILDING PHYSICS, 2016, 39 (06) : 542 - 569
  • [29] Assessment of energy and environmental performance of office building models: A case study
    Krstic-Furundzic, Aleksandra
    Kosic, Tatjana
    ENERGY AND BUILDINGS, 2016, 115 : 11 - 22
  • [30] An experimental study of thermal performance of the radiant ceiling cooling in office building in Thailand
    Aryal, Ashmin
    Chaiwiwatworakul, Pipat
    Chirarattananon, Surapong
    ENERGY AND BUILDINGS, 2023, 283