Assessment of energy and economic performance of office building models: a case study

被引:0
|
作者
Song, X. Y. [1 ,2 ]
Ye, C. T. [1 ]
Li, H. S. [1 ,2 ]
Wang, X. L. [1 ]
Ma, W. B. [1 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Energy Conservat, Key Lab Renewable Energy & Gas Hydrate, Guangzhou 510640, Guangdong, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
RESIDENTIAL BUILDINGS; SENSITIVITY-ANALYSIS; SIMULATION;
D O I
10.1088/1755-1315/40/1/012007
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Energy consumption of building accounts for more than 37.3% of total energy consumption while the proportion of energy-saving buildings is just 5% in China. In this paper, in order to save potential energy, an office building in Southern China was selected as a test example for energy consumption characteristics. The base building model was developed by TRNSYS software and validated against the recorded data from the field work in six days out of August-September in 2013. Sensitivity analysis was conducted for energy performance of building envelope retrofitting; five envelope parameters were analyzed for assessing the thermal responses. Results indicated that the key sensitivity factors were obtained for the heat-transfer coefficient of exterior walls (U-wall), infiltration rate and shading coefficient (SC), of which the sum sensitivity factor was about 89.32%. In addition, the results were evaluated in terms of energy and economic analysis. The analysis of sensitivity validated against some important results of previous studies. On the other hand, the cost-effective method improved the efficiency of investment management in building energy.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Assessment of energy and environmental performance of office building models: A case study
    Krstic-Furundzic, Aleksandra
    Kosic, Tatjana
    [J]. ENERGY AND BUILDINGS, 2016, 115 : 11 - 22
  • [2] Life Cycle Assessment Meeting Energy Standard Performance: An Office Building Case Study
    Pushkar, Svetlana
    Yezioro, Abraham
    [J]. BUILDINGS, 2022, 12 (02)
  • [3] Solar energy for air conditioning of an office building in a case study: Techno-economic feasibility assessment
    Haffaf, Aziz
    Lakdja, Fatiha
    Abdeslam, Djaffar Ould
    Meziane, Rachid
    [J]. RENEWABLE ENERGY FOCUS, 2021, 39 : 148 - 162
  • [4] Energy performance of an existing office building in the northern part of Italy: Retrofitting actions and economic assessment
    Valdiserri, Paolo
    Biserni, Cesare
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2016, 27 : 65 - 72
  • [5] Climate models for the assessment of office buildings energy performance
    Gugliermetti, F
    Passerini, G
    Bisegna, F
    [J]. BUILDING AND ENVIRONMENT, 2004, 39 (01) : 39 - 50
  • [6] Economic performance assessment of residential building retrofits: a case study of Istanbul
    Cetiner, Ikbal
    Metin, Buket
    [J]. ENERGY EFFICIENCY, 2017, 10 (05) : 1061 - 1079
  • [7] Economic performance assessment of residential building retrofits: a case study of Istanbul
    Ikbal Cetiner
    Buket Metin
    [J]. Energy Efficiency, 2017, 10 : 1061 - 1079
  • [8] Energy efficiency and conservation in an office building: a case study
    Hartungi, Rusdy
    Jiang, Liben
    [J]. INTERNATIONAL JOURNAL OF ENERGY SECTOR MANAGEMENT, 2012, 6 (02) : 175 - 188
  • [9] Energy efficient design of an office building: A case study
    Anderson, GO
    Grover, HK
    [J]. POWER AND ENERGY SYSTEMS, PROCEEDINGS, 2003, : 191 - 197
  • [10] Evaluation of daylighting performance in an office building: A case study
    Udhwani, Lokesh
    Soni, Archana
    [J]. MATERIALS TODAY-PROCEEDINGS, 2021, 46 : 5626 - 5631