Extent of simultaneous radiation dose and iodine reduction at stable image quality in computed tomography of the chest A systematic approach using automated tube voltage adaption and iterative reconstructions

被引:5
|
作者
Eller, Achim [1 ]
Wuest, Wolfgang [1 ,2 ]
Saake, Marc [1 ]
Ellmann, Stephan [1 ]
Kaemmerer, Nadine [1 ]
Hammon, Matthias [1 ]
Janka, Rolf [1 ]
Uder, Michael [1 ,2 ]
May, Matthias Stefan [1 ,2 ]
机构
[1] Univ Hosp Erlangen, Dept Radiol, Erlangen, Germany
[2] Imaging Sci Inst, Ulmenweg 18, Erlangen, Germany
关键词
adaptation; chest; computed tomography; contrast media; iterative reconstruction; radiation dose; tube voltage; CT ANGIOGRAPHY; CONTRAST MATERIAL; EXPOSURE; VOLUME; PROTOCOLS;
D O I
10.1097/MD.0000000000010388
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Aim of this study was to systematically combine tube voltage adaptation and iterative reconstructions for reduction of iodine and radiation dose. Methods: Settings for the study protocol were evaluated in ex-ante trials to provide image quality that is comparable to a reference protocol at 120kV with tube current modulation. Consecutive patients were randomized to undergo computed tomography (CT) of the chest using the study protocol (n=62) or reference protocol (n=50). Objective and subjective image quality was assessed and compared. Results: Tube voltage was decreased to 100kV in 47 patients and to 80kV in 15 patients in the study group. The iodine dosage (16.1 vs 10.5 g) and the effective radiation dose (3.6 vs 2.5mSv) were significantly decreased in the study group (both P<.001). Contrast-to-noise ratio was comparable in the pulmonary trunk and increased in the aorta (P<.01). Subjective image quality was comparable without statistically significance. Conclusions: Simultaneous reductions in iodine dosage and radiation dose by one-third are feasible for CT of the chest.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Automated Tube Voltage Selection in Thoracoabdominal Computed Tomography at High Pitch Using a Third-Generation Dual-Source Scanner Image Quality and Radiation Dose Performance
    Lurz, Markus
    Lell, Michael M.
    Wuest, Wolfgang
    Eller, Achim
    Scharf, Michael
    Uder, Michael
    May, Matthias Stefan
    INVESTIGATIVE RADIOLOGY, 2015, 50 (05) : 352 - 360
  • [22] Comparison of image quality and radiation dose in computed tomography angiography of the peripheral arteries using tube voltage of 80 kV versus 100 kV
    Pernas, R. Oca
    Delgado Sanchez-Gracian, C.
    Tardaguila de la Fuente, G.
    Fernandez del Valle, A.
    Silva Priegue, N.
    Gonzalez Vazquez, M.
    Trinidad Lopez, C.
    RADIOLOGIA, 2014, 56 (06): : 541 - 547
  • [23] Low-Dose Computed Tomography of the Chest Using Iterative Reconstruction Versus Filtered Back Projection: Comparison of Image Quality
    Lee, Youkyung
    Jin, Kwang Nam
    Lee, Nyoung Keun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 512 - 517
  • [24] A qualitative and quantitative analysis of radiation dose and image quality of computed tomography images using adaptive statistical iterative reconstruction
    Hussain, Fahad Ahmed
    Mail, Noor
    Shamy, Abdulrahman M.
    Alghamdi, Suliman
    Saoudi, Abdelhamid
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 419 - 432
  • [25] Automated Tube Voltage Adaptation in Combination with Advanced Modeled Iterative Reconstruction in Thoracoabdominal Third-Generation 192-Slice Dual-Source Computed Tomography: Effects on Image Quality and Radiation Dose
    Scholtz, Jan-Erik
    Wichmann, Julian L.
    Huesers, Kristina
    Beeres, Martin
    Nour-Eldin, Nour-Eldin Abdelrehim
    Frellesen, Claudia
    Vogl, Thomas J.
    Lehnert, Thomas
    ACADEMIC RADIOLOGY, 2015, 22 (09) : 1081 - 1087
  • [26] Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique
    Ying Wang
    Xiaohua Wang
    Yan Zhang
    Yuliu Lu
    Runze Wu
    Huishu Yuan
    The International Journal of Cardiovascular Imaging, 2014, 30 : 89 - 94
  • [27] Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique
    Wang, Ying
    Wang, Xiaohua
    Zhang, Yan
    Lu, Yuliu
    Wu, Runze
    Yuan, Huishu
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 : 89 - 94
  • [28] Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp
    Ji Eun Park
    Young Hun Choi
    Jung-Eun Cheon
    Woo Sun Kim
    In-One Kim
    Hyun Suk Cho
    Young Jin Ryu
    Yu Jin Kim
    Pediatric Radiology, 2017, 47 : 710 - 717
  • [29] Image quality and radiation dose of brain computed tomography in children: effects of decreasing tube voltage from 120 kVp to 80 kVp
    Park, Ji Eun
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In-One
    Cho, Hyun Suk
    Ryu, Young Jin
    Kim, Yu Jin
    PEDIATRIC RADIOLOGY, 2017, 47 (06) : 710 - 717
  • [30] Image Quality Measured From Ultra-Low Dose Chest Computed Tomography Examination Protocols Using 6 Different Iterative Reconstructions From 4 Vendors, a Phantom Study
    Afadzi, Mercy
    Fossa, Kristian
    Andersen, Hilde Kjernlie
    Aalokken, Trond Mogens
    Martinsen, Anne Catrine T.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (01) : 95 - 101