Extent of simultaneous radiation dose and iodine reduction at stable image quality in computed tomography of the chest A systematic approach using automated tube voltage adaption and iterative reconstructions

被引:5
|
作者
Eller, Achim [1 ]
Wuest, Wolfgang [1 ,2 ]
Saake, Marc [1 ]
Ellmann, Stephan [1 ]
Kaemmerer, Nadine [1 ]
Hammon, Matthias [1 ]
Janka, Rolf [1 ]
Uder, Michael [1 ,2 ]
May, Matthias Stefan [1 ,2 ]
机构
[1] Univ Hosp Erlangen, Dept Radiol, Erlangen, Germany
[2] Imaging Sci Inst, Ulmenweg 18, Erlangen, Germany
关键词
adaptation; chest; computed tomography; contrast media; iterative reconstruction; radiation dose; tube voltage; CT ANGIOGRAPHY; CONTRAST MATERIAL; EXPOSURE; VOLUME; PROTOCOLS;
D O I
10.1097/MD.0000000000010388
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Aim of this study was to systematically combine tube voltage adaptation and iterative reconstructions for reduction of iodine and radiation dose. Methods: Settings for the study protocol were evaluated in ex-ante trials to provide image quality that is comparable to a reference protocol at 120kV with tube current modulation. Consecutive patients were randomized to undergo computed tomography (CT) of the chest using the study protocol (n=62) or reference protocol (n=50). Objective and subjective image quality was assessed and compared. Results: Tube voltage was decreased to 100kV in 47 patients and to 80kV in 15 patients in the study group. The iodine dosage (16.1 vs 10.5 g) and the effective radiation dose (3.6 vs 2.5mSv) were significantly decreased in the study group (both P<.001). Contrast-to-noise ratio was comparable in the pulmonary trunk and increased in the aorta (P<.01). Subjective image quality was comparable without statistically significance. Conclusions: Simultaneous reductions in iodine dosage and radiation dose by one-third are feasible for CT of the chest.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Dose reduction and image quality improvement of chest radiography by using bone-suppression technique and low tube voltage: a phantom study
    Satoshi Takagi
    Tatsuya Yaegashi
    Masayori Ishikawa
    European Radiology, 2020, 30 : 571 - 580
  • [42] ADAPTIVE ITERATIVE DOSE REDUCTION IS ASSOCIATED WITH SIGNIFICANT REDUCTION IN TOTAL AND COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY RADIATION EXPOSURE AND IMPROVED IMAGE QUALITY, COMPARED TO TRADITIONAL FILTERED BACKPROJECTION ON 320-MULTIDETECTOR COMPUTED TOMOGRAPHY
    Aslam, Anum
    Khokhar, Usman
    Cortegiano, Michael
    Poon, Michael
    Voros, Szilard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E923 - E923
  • [43] Individualized reduction of radiation dose with a chest circumference-adapted technique and iterative reconstructions in 256-slice retrospective and prospective ECG-triggered computed tomography coronary angiography
    Li, Jing-Lei
    Huang, Mei-Ping
    Cao, Xi-Ming
    Cui, Yan-Hai
    Ivanc, Thomas B.
    Liang, Chang-Hong
    CORONARY ARTERY DISEASE, 2015, 26 (04) : 308 - 316
  • [44] Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography
    Zhang, Wei-Guo
    Liu, Jia-Ping
    Jia, Xiu-Qin
    Zhang, Ji-Yang
    Li, Xiang-Nan
    Yang, Qi
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 1033 - 1039
  • [45] Contrast-Enhanced Chest Computed Tomography (CT) Scan with Low Radiation and Total Iodine Dose for Lung Cancer Detection Using Adaptive Statistical Iterative Reconstruction
    Li, Xili
    Luo, Shiyong
    Chen, Suping
    Wang, Du
    Tan, Yiqing
    IRANIAN JOURNAL OF RADIOLOGY, 2022, 19 (04)
  • [46] Clinical evaluation of image quality and radiation dose reduction in upper abdominal computed tomography using model-based iterative reconstruction; comparison with filtered back projection and adaptive statistical iterative reconstruction
    Nakamoto, Atsushi
    Kim, Tonsok
    Hori, Masatoshi
    Onishi, Hiromitsu
    Tsuboyama, Takahiro
    Sakane, Makoto
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) : 1715 - 1723
  • [47] Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose
    Scholtz, Jan-Erik
    Wichmann, Julian L.
    Huesers, Kristina
    Albrecht, Moritz H.
    Beeres, Martin
    Bauer, Ralf W.
    Vogl, Thomas J.
    Bodelle, Boris
    EUROPEAN RADIOLOGY, 2016, 26 (08) : 2623 - 2631
  • [48] Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose
    Jan-Erik Scholtz
    Julian L. Wichmann
    Kristina Hüsers
    Moritz H. Albrecht
    Martin Beeres
    Ralf W. Bauer
    Thomas J. Vogl
    Boris Bodelle
    European Radiology, 2016, 26 : 2623 - 2631
  • [49] Radiation Exposure and Image Quality of Normal Computed Tomography Brain Images Acquired With Automated and Organ-Based Tube Current Modulation Multiband Filtering and Iterative Reconstruction
    Becker, Hans-Christoph
    Augart, Dominik
    Karpitschka, Martina
    Ulzheimer, Stefan
    Bamberg, Fabian
    Morhard, Dominik
    Neumaier, Klement
    Graser, Anno
    Johnson, Thorsten
    Reiser, Maximilian
    INVESTIGATIVE RADIOLOGY, 2012, 47 (03) : 202 - 207
  • [50] Iterative reconstruction and individualized automatic tube current selection reduce radiation dose while maintaining image quality in 320-multidetector computed tomography coronary angiography
    Williams, M. C.
    Weir, N. W.
    Mirsadraee, S.
    Millar, F.
    Baird, A.
    Minns, F.
    Uren, N. G.
    McKillop, G.
    Bull, R. K.
    van Beek, E. J. R.
    Reid, J. H.
    Newby, D. E.
    CLINICAL RADIOLOGY, 2013, 68 (11) : E570 - E577