Extent of simultaneous radiation dose and iodine reduction at stable image quality in computed tomography of the chest A systematic approach using automated tube voltage adaption and iterative reconstructions

被引:5
|
作者
Eller, Achim [1 ]
Wuest, Wolfgang [1 ,2 ]
Saake, Marc [1 ]
Ellmann, Stephan [1 ]
Kaemmerer, Nadine [1 ]
Hammon, Matthias [1 ]
Janka, Rolf [1 ]
Uder, Michael [1 ,2 ]
May, Matthias Stefan [1 ,2 ]
机构
[1] Univ Hosp Erlangen, Dept Radiol, Erlangen, Germany
[2] Imaging Sci Inst, Ulmenweg 18, Erlangen, Germany
关键词
adaptation; chest; computed tomography; contrast media; iterative reconstruction; radiation dose; tube voltage; CT ANGIOGRAPHY; CONTRAST MATERIAL; EXPOSURE; VOLUME; PROTOCOLS;
D O I
10.1097/MD.0000000000010388
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Aim of this study was to systematically combine tube voltage adaptation and iterative reconstructions for reduction of iodine and radiation dose. Methods: Settings for the study protocol were evaluated in ex-ante trials to provide image quality that is comparable to a reference protocol at 120kV with tube current modulation. Consecutive patients were randomized to undergo computed tomography (CT) of the chest using the study protocol (n=62) or reference protocol (n=50). Objective and subjective image quality was assessed and compared. Results: Tube voltage was decreased to 100kV in 47 patients and to 80kV in 15 patients in the study group. The iodine dosage (16.1 vs 10.5 g) and the effective radiation dose (3.6 vs 2.5mSv) were significantly decreased in the study group (both P<.001). Contrast-to-noise ratio was comparable in the pulmonary trunk and increased in the aorta (P<.01). Subjective image quality was comparable without statistically significance. Conclusions: Simultaneous reductions in iodine dosage and radiation dose by one-third are feasible for CT of the chest.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Dose Reduction in Computed Tomography of the Chest: Image Quality of Iterative Reconstructions at a 50% Radiation Dose Compared to Filtered Back Projection at a 100% Radiation Dose
    May, M. S.
    Eller, A.
    Stahl, C.
    Wuest, W.
    Scharf, M.
    Hammon, M.
    Dankerl, P.
    Schlechtweg, P. M.
    Allmendinger, T.
    Sedlmair, M.
    Schmidt, B.
    Uder, M.
    Lell, M. M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (06): : 576 - 584
  • [2] Radiation dose and image quality with abdominal computed tomography with automated dose-optimized tube voltage selection
    Hu, Lirong
    Wang, Yujun
    Hou, Hongtao
    Wei, Fuquan
    Yang, Guangzhao
    Chen, Yougeng
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2014, 42 (04) : 1011 - 1017
  • [3] Standard chest CT using combined automated tube potential selection and iterative reconstruction: image quality and radiation dose reduction
    Chae, In Hye
    Kim, Yookyung
    Lee, So Won
    Park, Ji Eun
    Shim, Sung Shine
    Lee, Jin Hwa
    CLINICAL IMAGING, 2014, 38 (05) : 641 - 647
  • [4] Achievable dose reduction using iterative reconstruction for chest computed tomography: A systematic review
    den Harder, Annemarlie M.
    Willemink, Martin J.
    de Ruiter, Quirina M. B.
    Schilham, Arnold M. R.
    Krestin, Gabriel P.
    Leiner, Tim
    de Jong, Pim A.
    Budde, Ricardo P. J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) : 2307 - 2313
  • [5] Evaluation of image quality and radiation dose in computed tomography urography following tube voltage optimisation
    Saidu, A. M.
    Garba, I.
    Abba, M.
    Yahuza, M. A.
    Yusuf, L.
    Tahir, N. M.
    Garko, S. S.
    RADIOGRAPHY, 2024, 30 (01) : 301 - 307
  • [6] Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography
    Mousavi-Gazafroudi, Seyedeh Shokoofeh
    Sajjadieh-Khajouei, Amirreza
    Moradi, Maryam
    Mousavi-Gazafroudi, Seyedeh Shabnam
    Yadegarfar, Ghasem
    Tavakoli, Mohammad Bagher
    ARYA ATHEROSCLEROSIS, 2019, 15 (05) : 205 - 210
  • [7] Computed Tomography Radiation Dose Reduction: Effect of Different Iterative Reconstruction Algorithms on Image Quality
    Willemink, Martin J.
    Takx, Richard A. P.
    de Jong, Pim A.
    Budde, Ricardo P. J.
    Bleys, Ronald L. A. W.
    Das, Marco
    Wildberger, Joachim E.
    Prokop, Mathias
    Buls, Nico
    de Mey, Johan
    Leiner, Tim
    Schilham, Arnold M. R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 815 - 823
  • [8] Improved Image Quality and Decreased Radiation Dose of Lower Extremity Computed Tomography Angiography Using Low-Tube-Voltage and Adaptive Iterative Reconstruction
    Pan, Yu-Ning
    Li, Ai-Jing
    Chen, Zhao-Qian
    Ren, Da-Wei
    Zhang, Jie
    Jiang, Mao-Qing
    Huang, Qiu-Li
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (02) : 272 - 276
  • [9] Automated tube voltage adaptation in head and neck computed tomography between 120 and 100 kV: effects on image quality and radiation dose
    Matthias S. May
    Manuel R. Kramer
    Achim Eller
    Wolfgang Wuest
    Michael Scharf
    Michael Brand
    Marc Saake
    Bernhard Schmidt
    Michael Uder
    Michael M. Lell
    Neuroradiology, 2014, 56 : 797 - 803
  • [10] Automated tube voltage adaptation in head and neck computed tomography between 120 and 100 kV: effects on image quality and radiation dose
    May, Matthias S.
    Kramer, Manuel R.
    Eller, Achim
    Wuest, Wolfgang
    Scharf, Michael
    Brand, Michael
    Saake, Marc
    Schmidt, Bernhard
    Uder, Michael
    Lell, Michael M.
    NEURORADIOLOGY, 2014, 56 (09) : 797 - 803