Evaluation of image quality and radiation dose in low tube voltage coronary computed tomography angiography

被引:7
|
作者
Mousavi-Gazafroudi, Seyedeh Shokoofeh [1 ]
Sajjadieh-Khajouei, Amirreza [2 ]
Moradi, Maryam [3 ]
Mousavi-Gazafroudi, Seyedeh Shabnam [4 ]
Yadegarfar, Ghasem [5 ,6 ]
Tavakoli, Mohammad Bagher [1 ]
机构
[1] Isfahan Univ Med Sci, Sch Med, Dept Med Phys, Esfahan, Iran
[2] Isfahan Univ Med Sci, Cardiac Rehabil Res Ctr, Cardiovasc Res Inst, Esfahan, Iran
[3] Isfahan Univ Med Sci, Sch Med, Dept Radiol, Esfahan, Iran
[4] Tarbiat Modares Univ, Sch Med, Dept Med Phys, Tehran, Iran
[5] Isfahan Univ Med Sci, Sch Publ Hlth, Cardiovasc Res Inst, Heart Failure Res Ctr, Esfahan, Iran
[6] Isfahan Univ Med Sci, Sch Publ Hlth, Dept Epidemiol & Biostat, Esfahan, Iran
关键词
Coronary Angiography; Computed Tomography Angiography; Radiation Dosage; Contrast Agent; X-Rays; Image Enhancement; DUAL-SOURCE CT; 100; KVP; OBESE-PATIENTS; REDUCTION; PROTOCOL; EXPOSURE; IMPACT; CHEST;
D O I
10.22122/arya.v15i5.1406
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Coronary computed tomography angiography (CCTA) is an important modality in diagnosis of coronary artery disease (CAD). Owing to the fact that computed tomography (CT) examinations are performed using ionizing radiation; applying radiation dose-reduction strategies seems to be necessary. Lowering tube voltage (in kV) according to the patient's body mass index (BMI) or weight is an approach that is investigated by many researchers. The goal of this study was to evaluate the impact of low tube voltage CCTA on radiation dose and image quality in order to decrease radiation dose in selected patients who meet inclusion criteria of the introduced protocol. METHODS: Patients with clinical indications of CCTA who met inclusion criteria were classified in two groups randomly. Imaging of two groups was performed using 120 kV and 100 kV, respectively. Subjective and objective parameters of image quality and radiation dose of two groups were measured. Afterward, data were analyzed by appropriate statistical tests using SPSS software. RESULTS: While differences in image quality between two groups were not significant, radiation dose of patients who underwent 100 kV CCTA was significantly lower than the other group. Effective doses (EDs) of first and second groups were 22.30 +/- 5.48 mSv and 13.82 +/- 2.00 mSv, respectively (P < 0.001). CONCLUSION: Lowering tube voltage in non-obese patients is an effective and practical approach to radiation dose reduction without missing image quality that should be considered especially for female patients.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [1] Coronary Computed Tomography Angiography With Very Low Tube Voltage Reduces Radiation Dose and Maintains Image Quality
    Daubert, Melissa A.
    Goldman, Mark
    Chen, John
    Feldmann, Eric
    Ferraro, Summer
    Hellinger, Jeffrey
    Poon, Michael
    [J]. CIRCULATION, 2011, 124 (21)
  • [2] Image Quality in Computed Tomography Coronary Angiography and Radiation Dose Reduction
    Golubickas, Domas
    Lukosevicius, Saulius
    Tamakauskas, Vytenis
    Dobrovolskiene, Laima
    Baseviciene, Ingrida
    Grib, Liviu
    Ragaisyte, Nijole
    Leonavicius, Rytis
    Medvedev, Viktor
    Veikutis, Vincentas
    [J]. INFORMATICA, 2021, 32 (04) : 741 - 757
  • [3] Evaluation of image quality and radiation dose in computed tomography urography following tube voltage optimisation
    Saidu, A. M.
    Garba, I.
    Abba, M.
    Yahuza, M. A.
    Yusuf, L.
    Tahir, N. M.
    Garko, S. S.
    [J]. RADIOGRAPHY, 2024, 30 (01) : 301 - 307
  • [4] Low radiation dose computed tomography coronary angiography: evaluation of the variations in coronary arteries
    Nurullah Dogan
    Aydin Dursun
    Hakan Ozkan
    Serdar Karataş
    Nuran Celiloglu
    Fahriye Vatansever Agca
    [J]. Surgical and Radiologic Anatomy, 2016, 38 : 1123 - 1134
  • [5] Low radiation dose computed tomography coronary angiography: evaluation of the variations in coronary arteries
    Dogan, Nurullah
    Dursun, Aydin
    Ozkan, Hakan
    Karatas, Serdar
    Celiloglu, Nuran
    Agca, Fahriye Vatansever
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2016, 38 (10) : 1123 - 1134
  • [6] REDUCING IN RADIATION DOSE OF CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY BY DECREASING TUBE VOLTAGE TO 100 KVP
    Alani, Anas
    Nakanishi, Rine
    Luo, Yanting
    Rezaeian, Panteha
    Matsumoto, Suguru
    Budoff, Matthew
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1052 - A1052
  • [7] Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality
    Komatsu, Sei
    Kamata, Teruaki
    Imai, Atsuko
    Ohara, Tomoki
    Takewa, Mitsuhiko
    Ohe, Ryoko
    Miyaji, Kazuaki
    Yoshida, Junichi
    Kodama, Kazuhisa
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06): : 1335 - 1340
  • [8] Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality
    Sei Komatsu
    Teruaki Kamata
    Atsuko Imai
    Tomoki Ohara
    Mitsuhiko Takewa
    Ryoko Ohe
    Kazuaki Miyaji
    Junichi Yoshida
    Kazuhisa Kodama
    [J]. The International Journal of Cardiovascular Imaging, 2013, 29 : 1335 - 1340
  • [9] Application of Aortic Computed Tomography Angiography with Low Radiation Dose: Assessment of Image Quality and Radiation Dose
    Liu, Jianhua
    Li, Long
    Zhang, Yan
    Yuan, Qinghai
    Sun, Yong
    [J]. 2012 IEEE FIFTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTATIONAL INTELLIGENCE (ICACI), 2012, : 148 - 151
  • [10] Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique
    Ying Wang
    Xiaohua Wang
    Yan Zhang
    Yuliu Lu
    Runze Wu
    Huishu Yuan