Calibration-based thermal error model for articulated arm coordinate measuring machines

被引:70
|
作者
Santolaria, Jorge [1 ]
Yaguee, Jose-Antonio [1 ]
Jimenez, Roberto [1 ]
Aguilar, Juan-Jose [1 ]
机构
[1] Univ Zaragoza, Dept Design & Mfg Engn, Zaragoza 50018, Spain
关键词
Coordinate measurement arms; Thermal error model; Parameter identification; Data capture; Error correction; COMPENSATION; ACCURACY; CMM;
D O I
10.1016/j.precisioneng.2009.01.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The influence of thermal changes in the accuracy of articulated arm coordinate measuring machines (AACMMs) is one of their main error sources. Usually, the effects of this problem are minimized by using low thermal-expansion materials in the arm design or by implementing an empirical error correction model based on the outputs of several temperature sensors placed inside the arm. These models, inherited from temperature correction models for robot arms, are based on the empirical arm positioning error characterization of several temperatures inside its measuring range and by posterior corrections implemented using an average error approximation. Considering this approximation as a correction valid for all the temperature range violates the AACMM calibration conditions, which are defined by a kinematic parameter identification procedure at 20 degrees C. This implies that, by applying these models, the AACMM will work outside of calibration conditions and will not meet the nominal accuracy values obtained from the identification procedure. In this work a new empirical correction model for thermal errors is presented. This model keeps the calibration conditions established in the parameters identification procedure unaltered. This fact makes it possible to apply other correction models for geometric and non-geometric errors obtained at the calibration temperature after having applied the temperature correction. The algorithm and objective functions used, which are based on a new approach including terms regarding measurement accuracy and repeatability and using the measurements of a ball-beam gauge artifact are shown. The empirical correction model and the arm accuracy and repeatability results before and after correction are also explained, showing an important accuracy improvement in the arm performance for typical arm operation at temperatures different from 20 degrees C. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:476 / 485
页数:10
相关论文
共 50 条
  • [41] The length error compensation method of articulated arm coordinate measuring machine
    Feng, Xugang
    Zhu, Jiaqi
    Zhang, Jiayan
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (10):
  • [42] Multi-posture kinematic calibration technique, and parameter identification algorithm for articulated arm coordinate measuring machines
    Aguilar, Juan-Jose
    Santolaria, Jorge
    Yaguee, Jose-Antonio
    Majarena, Ana-Cristina
    IMETI 2008: INTERNATIONAL MULTI-CONFERENCE ON ENGINEERING AND TECHNOLOGICAL INNOVATION, VOL I, PROCEEDINGS, 2008, : 1 - 6
  • [43] Structure Parameter Identification of Articulated Arm Coordinate Measuring Machines Based on the Least Squares Method
    Lu, Jian
    Gao, Guanbin
    Yang, Huiping
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 638 - 641
  • [44] A Calibration Method for the Articulated Arm Coordinate Measuring Machine Based on Carbon Fiber Standard Gauge
    Xie, Pei
    Gao, Guanbin
    Na, Jing
    Yang, Chunxi
    Han, Shichang
    Zeng, Zhijang
    TENTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2021, 12059
  • [45] EVALUATION OF DIFFERENT PROBING SYSTEMS USED IN ARTICULATED ARM COORDINATE MEASURING MACHINES
    Bran, Agustin
    Valenzuela, Margarita
    Santolaria, Jorge
    Jose Aguilar, Juan
    METROLOGY AND MEASUREMENT SYSTEMS, 2014, 21 (02) : 233 - 246
  • [46] Kinematics Identification and Measurement Accuracy Verification of Articulated Arm Coordinate Measuring Machines
    Wang, Sen
    Gao, Guanbin
    Zhao, Jun
    Na, Jing
    Wang, Wen
    TENTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2019, 11053
  • [47] Analysis and Compensation of Equivalent Diameter Error of Articulated Arm Coordinate Measuring Machine
    Luo, Zai
    Liu, Hui
    Li, Dong
    Tian, Kun
    MEASUREMENT & CONTROL, 2018, 51 (1-2): : 16 - 26
  • [48] Multi-point calibration method for articulated arm coordinate measuring machine based on an observability index
    Wang, Chuanyong
    Wang, Wen
    Wei, Zhuzhu
    Yang, He
    Wang, Le
    Chen, Zhanfeng
    Lu, Keqing
    Liang, Qianqian
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (12)
  • [49] Calibration of articulated arm coordinate measuring machine with two parallel rotational axes based on the reversal method
    Qiu, Zurong
    Chen, Bo
    Li, Xinghua
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2014, 47 (06): : 512 - 517
  • [50] CALIBRATION OF COORDINATE MEASURING MACHINES
    BUSCH, K
    KUNZMANN, H
    WALDELE, F
    PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1985, 7 (03): : 139 - 144