Calibration-based thermal error model for articulated arm coordinate measuring machines

被引:70
|
作者
Santolaria, Jorge [1 ]
Yaguee, Jose-Antonio [1 ]
Jimenez, Roberto [1 ]
Aguilar, Juan-Jose [1 ]
机构
[1] Univ Zaragoza, Dept Design & Mfg Engn, Zaragoza 50018, Spain
关键词
Coordinate measurement arms; Thermal error model; Parameter identification; Data capture; Error correction; COMPENSATION; ACCURACY; CMM;
D O I
10.1016/j.precisioneng.2009.01.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The influence of thermal changes in the accuracy of articulated arm coordinate measuring machines (AACMMs) is one of their main error sources. Usually, the effects of this problem are minimized by using low thermal-expansion materials in the arm design or by implementing an empirical error correction model based on the outputs of several temperature sensors placed inside the arm. These models, inherited from temperature correction models for robot arms, are based on the empirical arm positioning error characterization of several temperatures inside its measuring range and by posterior corrections implemented using an average error approximation. Considering this approximation as a correction valid for all the temperature range violates the AACMM calibration conditions, which are defined by a kinematic parameter identification procedure at 20 degrees C. This implies that, by applying these models, the AACMM will work outside of calibration conditions and will not meet the nominal accuracy values obtained from the identification procedure. In this work a new empirical correction model for thermal errors is presented. This model keeps the calibration conditions established in the parameters identification procedure unaltered. This fact makes it possible to apply other correction models for geometric and non-geometric errors obtained at the calibration temperature after having applied the temperature correction. The algorithm and objective functions used, which are based on a new approach including terms regarding measurement accuracy and repeatability and using the measurements of a ball-beam gauge artifact are shown. The empirical correction model and the arm accuracy and repeatability results before and after correction are also explained, showing an important accuracy improvement in the arm performance for typical arm operation at temperatures different from 20 degrees C. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:476 / 485
页数:10
相关论文
共 50 条
  • [31] Modelling and compensation of temperature errors for articulated arm coordinate measuring machines
    Gao, Guanbin
    Ma, Wenjin
    Na, Jing
    Liu, Fei
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2020, 35 (04) : 305 - 315
  • [32] Design Of A Data Acquisition System Of Articulated Arm Coordinate Measuring Machines
    Yang, Huiping
    Gao, Guanbin
    Wang, Wen
    NINTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2015, 9446
  • [33] Decoupling of Kinematic Parameter Identification for Articulated Arm Coordinate Measuring Machines
    Gao, Guanbin
    Zhao, Jun
    Na, Jing
    IEEE ACCESS, 2018, 6 : 50433 - 50442
  • [34] Articulated arm coordinate measurement machines
    Nagataki Y.
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2019, 85 (05): : 392 - 395
  • [35] A kinematic parameter Calibration method for Articulated Arm Coordinate Measuring Machine
    Zhao, Shuang
    Zhu, Lianqing
    Chen, Qingshan
    Pan, Zhikang
    Guo, Yangkuan
    SIXTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2013, 8916
  • [36] Articulated Arm Coordinate Measuring Machine Calibration by Laser Tracker Multilateration
    Santolaria, Jorge
    Majarena, Ana C.
    Samper, David
    Brau, Agustin
    Velazquez, Jesus
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [37] Calibration and error compensation of portable coordinate measuring arm
    Liu, Wanli
    Qu, Xinghua
    Yan, Yonggang
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2007, 28 (SUPP. 4): : 81 - 84
  • [38] Design and Validation of a Self-Driven Joint Model for Articulated Arm Coordinate Measuring Machines
    Hu, Yi
    Huang, Wei
    Hu, Peng-Hao
    Liu, Wen-Wen
    Ye, Bing
    APPLIED SCIENCES-BASEL, 2019, 9 (15):
  • [39] Multi-measure model calibration method for the Articulated Arm Coordinate Measuring Machine based on posture sets
    Song, Meng
    Wang, Wen
    Lu, Keqing
    Zhao, Dongpo
    Wang, Chuanyong
    Chen, Zhanfeng
    Shi, Guang
    MEASUREMENT, 2025, 246
  • [40] Modelling and Calibration Technique of Laser Triangulation Sensors for Integration in Robot Arms and Articulated Arm Coordinate Measuring Machines
    Santolaria, Jorge
    Guillomia, David
    Cajal, Carlos
    Albajez, Jose A.
    Aguilar, Juan J.
    SENSORS, 2009, 9 (09) : 7374 - 7396