Calibration-based thermal error model for articulated arm coordinate measuring machines

被引:70
|
作者
Santolaria, Jorge [1 ]
Yaguee, Jose-Antonio [1 ]
Jimenez, Roberto [1 ]
Aguilar, Juan-Jose [1 ]
机构
[1] Univ Zaragoza, Dept Design & Mfg Engn, Zaragoza 50018, Spain
关键词
Coordinate measurement arms; Thermal error model; Parameter identification; Data capture; Error correction; COMPENSATION; ACCURACY; CMM;
D O I
10.1016/j.precisioneng.2009.01.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The influence of thermal changes in the accuracy of articulated arm coordinate measuring machines (AACMMs) is one of their main error sources. Usually, the effects of this problem are minimized by using low thermal-expansion materials in the arm design or by implementing an empirical error correction model based on the outputs of several temperature sensors placed inside the arm. These models, inherited from temperature correction models for robot arms, are based on the empirical arm positioning error characterization of several temperatures inside its measuring range and by posterior corrections implemented using an average error approximation. Considering this approximation as a correction valid for all the temperature range violates the AACMM calibration conditions, which are defined by a kinematic parameter identification procedure at 20 degrees C. This implies that, by applying these models, the AACMM will work outside of calibration conditions and will not meet the nominal accuracy values obtained from the identification procedure. In this work a new empirical correction model for thermal errors is presented. This model keeps the calibration conditions established in the parameters identification procedure unaltered. This fact makes it possible to apply other correction models for geometric and non-geometric errors obtained at the calibration temperature after having applied the temperature correction. The algorithm and objective functions used, which are based on a new approach including terms regarding measurement accuracy and repeatability and using the measurements of a ball-beam gauge artifact are shown. The empirical correction model and the arm accuracy and repeatability results before and after correction are also explained, showing an important accuracy improvement in the arm performance for typical arm operation at temperatures different from 20 degrees C. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:476 / 485
页数:10
相关论文
共 50 条
  • [1] Error Modeling and Analysis of Articulated Arm Coordinate Measuring Machines
    Lu, Jian
    Gao, Guanbin
    Yang, Huiping
    ADVANCES IN APPLIED SCIENCE AND INDUSTRIAL TECHNOLOGY, PTS 1 AND 2, 2013, 798-799 : 464 - 467
  • [2] A SELF-CALIBRATION METHOD FOR ARTICULATED ARM COORDINATE MEASURING MACHINES
    Gao, Guanbin
    Na, Jing
    Wu, Xing
    Guo, Yu
    TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 2016, 40 (04) : 645 - 655
  • [3] Simulation of error analysis for flexible articulated arm coordinate measuring machines
    Huang, Kui
    Mo, Jian-Hua
    Zhong, Kai
    Yu, Li-Hua
    Shi, Yu-Sheng
    Wang, Cong-Jun
    Beijing Keji Daxue Xuebao/Journal of University of Science and Technology Beijing, 2010, 32 (10): : 1346 - 1352
  • [4] Mathematical model and parameter calibration of articulated arm coordinate measuring machine
    Feng, Xugang
    Zhu, Jiaqi
    Zhang, Jiayan
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2 (190-197): : 190 - 197
  • [5] Kinematic Calibration for Articulated Arm Coordinate Measuring Machines Base on Particle Swarm Optimization
    Gao, Guanbin
    Wang, Wen
    Lin, Keng
    Chen, Zichen
    ICICTA: 2009 SECOND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL I, PROCEEDINGS, 2009, : 189 - 192
  • [6] Adaptive Calibration for Articulated Arm Coordinate Measuring Machine
    Furutani, Ryoshu
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON MEASUREMENT AND QUALITY CONTROL - CYBER PHYSICAL ISSUE (IMEKO TC 14 2019), 2019, : 155 - 161
  • [7] Performance Calibration of Articulated Arm Coordinate Measuring Machine
    Mutilba, Unai
    Kortaberria, Gorka
    Olarra, Aitor
    Gutierrez, Antonio
    Gomez-Acedo, Eneko
    Zubieta, Mikel
    MANUFACTURING ENGINEERING SOCIETY INTERNATIONAL CONFERENCE, (MESIC 2013), 2013, 63 : 720 - 727
  • [8] Methodology for the assessment of measuring uncertainties of articulated arm coordinate measuring machines
    Romdhani, Fekria
    Hennebelle, Francois
    Ge, Min
    Juillion, Patrick
    Coquet, Richard
    Fontaine, Jean Francois
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (12)
  • [9] Residual modelling and compensation for articulated arm coordinate measuring machines based on compound calibration and extreme learning machine
    Gao G.
    Xie P.
    Liu F.
    Na J.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2023, 31 (22): : 3289 - 3304
  • [10] Kinematic parameter estimation technique for calibration and repeatability improvement of articulated arm coordinate measuring machines
    Santolaria, Jorge
    Aguilar, Juan-Jose
    Yaguee, Jose-Antonio
    Pastor, Jorge
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2008, 32 (04): : 251 - 268