An experimental study on a full-scale indoor thermal environment using an Under-Floor Air Distribution system

被引:25
|
作者
Lin, Y. J. P. [1 ]
Tsai, T. Y. [1 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Mech Engn, Taipei 106, Taiwan
基金
美国国家科学基金会;
关键词
Under-Floor Air Distribution (UFAD) system; Vertical temperature profile; Stratification height; Throw height; Jet flow; Gravity current; ENERGY; STRATIFICATION; VENTILATION; BUILDINGS;
D O I
10.1016/j.enbuild.2014.05.028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Characteristics of thermal environment in a full-scale indoor space utilizing an Under-Floor Air Distribution (UFAD) system are investigated by conducting and analyzing experimental measurements. The indoor air stratification of different locations in the steady state for three supply flow rate options is presented. This research focuses on the influence of supply air flow rate, and its corresponding momentum and buoyancy fluxes, on the vertical temperature profile in the indoor environment. Temperature measurements show that the indoor vertical temperature profile is influenced highly by the distance away from the supply diffuser position. Experimental results also show that the supply air flow rate has a strong effect on the vertical temperature profile. When the supply air flow rate of a given diffuser increases, and then the supply air momentum flux increases as well, the gradient of the vertical temperature profile becomes gentler. The stratification height in the indoor environment ascends with a higher total flow rate. The almost same throw height at the supply diffuser is observed for the identical flow rate option in two sets of experiments with different total flow rates. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 50 条
  • [41] Full-scale experimental study on fire under vehicle operations in a sloped tunnel
    Yang, Yuxuan
    Liu, Chang
    Long, Zeng
    Qiu, Peiyun
    Chen, Jiacheng
    Zhong, Maohua
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2020, 158
  • [42] Design, fabrication, and experimental study of a full-scale compressed air ejection system based on missile acceleration limitation
    Gao, Yang
    Wang, Cheng
    Sun, Yuanbo
    AEROSPACE SCIENCE AND TECHNOLOGY, 2023, 141
  • [43] Full-Scale Distribution System Topology Identification Using Markov Random Field
    Zhao, Jian
    Li, Liang
    Xu, Zhao
    Wang, Xiaoyu
    Wang, Haobo
    Shao, Xianjun
    IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (06) : 4714 - 4726
  • [44] Assessment of Personal Relaxation in Indoor-Air Environments: Study in Real Full-Scale Laboratory Houses
    Nakayama, Yoshitake
    Suzuki, Norimichi
    Nakaoka, Hiroko
    Tsumura, Kayo
    Takaguchi, Kohki
    Takaya, Kazunari
    Hanazato, Masamichi
    Todaka, Emiko
    Mori, Chisato
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (19)
  • [45] Experimental study on fire resistance properties of full-scale flat-plate floor subjected to fire
    Zhu, C. (zhuchongji80@163.com), 1600, Science Press (34):
  • [46] Full-scale experimental investigation on temperature distribution and smoke spread control in indoor pedestrian street atrium fires
    Fan, Chuangang
    Sheng, Ziqiong
    Jiao, Ao
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2023, 56 (11): : 56 - 63
  • [47] Full-scale experimental and simulation study of the influences of laneway fire on ventilation system
    Yao, Yongzheng
    Zhang, Wenming
    Wu, Bing
    Lei, Bowei
    Chen, Xinyu
    Meng, Yu
    Zhongguo Kuangye Daxue Xuebao/Journal of China University of Mining and Technology, 2021, 50 (04): : 709 - 715
  • [48] Experimental Study on the Behavior of Full-Scale Composite Steel Frames under Furnace Loading
    Dong, Yuli
    Prasad, Kuldeep
    JOURNAL OF STRUCTURAL ENGINEERING, 2009, 135 (10) : 1278 - 1289
  • [49] Experimental study on the behavior of full-scale composite steel frames under furnace loading
    Harbin Institute of Technology Professor, School of Civil Engineering, Harbin Institute of Technology, China
    不详
    不详
    J Struct Eng, 10 (1278-1289):
  • [50] Experimental Study on Full-Scale Light Frame Wood House under Lateral Load
    Chen Songlai
    Fan Chengmou
    Pan Jinglong
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (07): : 805 - 812