Assessment of Personal Relaxation in Indoor-Air Environments: Study in Real Full-Scale Laboratory Houses

被引:5
|
作者
Nakayama, Yoshitake [1 ]
Suzuki, Norimichi [1 ]
Nakaoka, Hiroko [1 ,2 ]
Tsumura, Kayo [1 ,3 ]
Takaguchi, Kohki [1 ]
Takaya, Kazunari [4 ]
Hanazato, Masamichi [1 ]
Todaka, Emiko [1 ,2 ]
Mori, Chisato [1 ,2 ]
机构
[1] Chiba Univ, Ctr Prevent Med Sci, 6-2-1 Kashiwanoha, Kashiwa, Chiba 2770882, Japan
[2] Chiba Univ, Grad Sch Med, Dept Bioenvironm Med, Chuo Ku, 1-8-1 Inohana, Chiba 2608670, Japan
[3] Chiba Univ, Grad Sch Med & Pharmaceut Sci, Chuo Ku, 1-8-1 Inohana, Chiba 2608670, Japan
[4] Natl Inst Occupat Safety & Hlth, Tama Ku, 6-21-1 Nagao, Kawasaki, Kanagawa 2148585, Japan
基金
日本学术振兴会;
关键词
indoor-air quality; volatile organic compounds; odor; questionnaire; electroencephalogram; laboratory houses; SICK-BUILDING SYNDROME; EEG ALPHA; PERFORMANCE; QUALITY;
D O I
10.3390/ijerph181910246
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The relationship between chemical concentrations in indoor air and the human sense of comfort and relaxation have been reported. We investigated the effect of the sum of volatile organic compounds (sigma VOCs; sum of 79 VOCs) on the level of relaxation in two laboratory houses with almost identical interior and exterior appearances. The electroencephalogram (EEG) was monitored to evaluate the degree of personal relaxation objectively. The experiments were conducted in laboratory houses (LH) A and B with lower and higher levels of sigma VOCs, respectively. A total of 168 healthy volunteers participated, who each performed the task for 20 min, followed by a 10-min break, and EEG was measured during the break. Simultaneously as subjective evaluations, the participants were asked to fill a questionnaire regarding the intensity of odor and preference for the air quality in each LH. The subjective evaluation showed a significant association between sigma VOCs and participants' relaxation (OR: 2.86, 95%CI: 1.24-6.61), and the objective evaluation indicated that the participants were more relaxed in the LH with lower levels of sigma VOCs than that with higher levels (OR: 3.03, 95%CI: 1.23-7.50). Therefore, the reduction of sigma VOCs and odors in indoor air would have an effect, which is the promotion of relaxation.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Full-scale measurements of indoor air flow
    Handa, K
    Pietrzyk, K
    17TH AIVC CONFERENCE - OPTIMUM VENTILATION AND AIR FLOW CONTROL IN BUILDING, PROCEEDINGS, VOLS 1 AND 2, 1996, : 273 - 281
  • [2] Estimating formaldehyde concentrations in indoor air in a full-scale test house
    Yoshida, H
    Nanami, N
    Ohono, T
    Inoue, A
    Tamura, A
    Omi, K
    WOOD ADHESIVES 2000, 2001, : 283 - 284
  • [3] Association between sum of volatile organic compounds and occurrence of building-related symptoms in humans: A study in real full-scale laboratory houses
    Suzuki, Norimichi
    Nakaoka, Hiroko
    Nakayama, Yoshitake
    Tsumura, Kayo
    Takaguchi, Kohki
    Takaya, Kazunari
    Eguchi, Akifumi
    Hanazato, Masamichi
    Todaka, Emiko
    Mori, Chisato
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 750
  • [4] A laboratory and full-scale study on the fragmentation behavior of rocks
    Bohloli, B.
    Hoven, E.
    ENGINEERING GEOLOGY, 2007, 89 (1-2) : 1 - 8
  • [5] Laboratory testing of full-scale in-duct gas air cleaners
    VanOsdell, Douglas W.
    Rodes, Charles E.
    Owen, M. Kathleen
    ASHRAE Transactions 2006, Vol 112, Pt 2, 2006, 112 : 418 - 429
  • [6] Full-scale determination of essential oil diffusion: Impact on indoor air quality
    Angulo-Milhem, Shadia
    Verriele, Marie
    Nicolas, Melanie
    Thevenet, Frederic
    ATMOSPHERIC ENVIRONMENT, 2023, 315
  • [7] Full-scale multisampling and empirical modeling of DBPs in water and air of indoor pools
    Ahmadpour, Elham
    Delpla, Ianis
    Debia, Maximilien
    Simard, Sabrina
    Proulx, Francois
    Serodes, Jean-Baptiste
    Valois, Isabelle
    Tardif, Robert
    Haddad, Sami
    Rodriguez, Manuel
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2023, 195 (09)
  • [8] Verification of air cleaner on-site modeling for PM2.5 and TVOC purification in a full-scale indoor air quality laboratory
    Shiue, Angus
    Hu, Shih-Cheng
    Tseng, Chao-Heng
    Kuo, En-Huai
    Liu, Chao-Yun
    Hou, Chia-Te
    Yu, Tuan
    ATMOSPHERIC POLLUTION RESEARCH, 2019, 10 (01) : 209 - 218
  • [9] Full-scale multisampling and empirical modeling of DBPs in water and air of indoor pools
    Elham Ahmadpour
    Ianis Delpla
    Maximilien Debia
    Sabrina Simard
    François Proulx
    Jean-Baptiste Sérodes
    Isabelle Valois
    Robert Tardif
    Sami Haddad
    Manuel Rodriguez
    Environmental Monitoring and Assessment, 2023, 195