Determination of total and unbound concentrations of lopinavir in plasma using liquid chromatography-tandem mass spectrometry and ultrafiltration methods

被引:17
|
作者
Illamola, S. M. [1 ]
Labat, L. [2 ]
Benaboud, S. [2 ,3 ]
Tubiana, R. [4 ,5 ]
Warszawski, J. [6 ,7 ,8 ]
Treluyer, J. M. [1 ,2 ,3 ,9 ]
Hirt, D. [2 ,3 ]
机构
[1] Hop Tarnier, AP HP, Unite Rech Clin, F-75006 Paris, France
[2] Grp Hosp Pitie Salpetriere, AP HP, Paris Ctr, Serv Pharmacol Clin, F-75634 Paris, France
[3] Univ Paris 05, Sorbonne Paris Cite, EAU08, Paris, France
[4] Hop La Pitie Salpetriere, AP HP, Serv Malad Infect, Paris, France
[5] UPMC Paris 06, Univ Paris 04, UMR Pierre Louis Inst Epidemiol & Publ Hlth S 113, F-75013 Paris, France
[6] INSERM, Ctr Res Epidemiol & Populat Hlth, Equipe VIH & IST, U1018, F-94275 Le Kremlin Bicetre, France
[7] Hop Bicetre, AP HP, Serv Epidemiol & Sante Publ, Le Kremlin Bicetre, France
[8] Univ Paris 11, UMRS 1018, Le Kremlin Bicetre, France
[9] INSERM, CIC 0901, Paris, France
关键词
Lopinavir; Unbound fraction; Ultrafiltration; Nonspecific binding; UPLC-MS/MS; HIV-PROTEASE INHIBITORS; REVERSE-TRANSCRIPTASE INHIBITORS; BLOOD MONONUCLEAR-CELLS; ANTIRETROVIRAL DRUGS; SIMULTANEOUS QUANTIFICATION; QUANTITATIVE-ANALYSIS; NONSPECIFIC-BINDING; RITONAVIR; VALIDATION; MS/MS;
D O I
10.1016/j.jchromb.2014.06.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Lopinavir is an HIV protease inhibitor with high protein binding (98-99%) in human plasma. This study was designed to develop an ultrafiltration method to measure the unbound concentrations of lopinavir overcoming the non-specific binding issue. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of total concentrations of lopinavir in plasma was developed and validated, and an adaptation was also optimized and validated for the determination of unbound concentrations. The chromatographic separation was performed with a C-18 column (100 mm x 2.1 mm i.d., 5 mu m particle size) using a mobile phase containing deionized water with formic acid, and acetonitrile, with gradient elution at a flow-rate of 350 mu Lmin(-1). Identification of the compounds was performed by multiple reaction monitoring, using electrospray ionization in positive ion mode. The method was validated over a clinical range of 0.01-1 mu g/mL for human plasma ultrafiltrate and 0.1-15 mu g/mL in human plasma. The inter and intra-assay accuracies and precisions were between 0.23% and 11.37% for total lopinavir concentrations, and between 3.50% and 13.30% for plasma ultrafiltrate (unbound concentration). The ultrafiltration method described allows an accurate separation of the unbound fraction of lopinavir, circumscribing the loss of drug by nonspecific binding (NSB), and the validated LC-MS/MS methodology proposed is suitable for the determination of total and unbound concentrations of lopinavir in clinical practice. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 50 条
  • [41] Determination of total and unbound ribociclib in human plasma and brain tumor tissues using liquid chromatography coupled with tandem mass spectrometry
    Bao, Xun
    Wu, Jianmei
    Sanai, Nader
    Li, Jing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 166 : 197 - 204
  • [42] Determination of amprenavir total and unbound concentrations in plasma by high-performance liquid chromatography and ultrafiltration
    Barrail, A
    Le Tiec, C
    Paci-Bonaventure, S
    Furlan, V
    Vincent, I
    Taburet, AM
    THERAPEUTIC DRUG MONITORING, 2006, 28 (01) : 89 - 94
  • [43] High performance liquid chromatography-tandem mass spectrometry for the determination of bile acid concentrations in human plasma
    Xiang, Xiaoqiang
    Han, Yi
    Neuvonen, Mikko
    Laitila, Jouko
    Neuvonen, Pertti J.
    Niemi, Mikko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (01): : 51 - 60
  • [44] Total determination of chloramphenicol residues in foods by liquid chromatography-tandem mass spectrometry
    Kikuchi, Hiroyuki
    Sakai, Takatoshi
    Teshima, Reiko
    Nemoto, Satoru
    Akiyama, Hiroshi
    FOOD CHEMISTRY, 2017, 230 : 589 - 593
  • [45] Quantification of total and unbound tranexamic acid in human plasma by ultrafiltration liquid chromatography/tandem mass spectrometry: Application to pharmacokinetic analysis
    Delavenne, Xavier
    Montbel, Adeline
    Hodin, Sophie
    Zufferey, Paul
    Basset, Thierry
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 91 : 32 - 36
  • [46] Determination of dalcetrapib by liquid chromatography-tandem mass spectrometry
    Heinig, Katja
    Bucheli, Franz
    Kuhlmann, Olaf
    Zell, Manfred
    Paehler, Axel
    Zwanziger, Elke
    Gross, Guenter
    Tardio, Joseph
    Ishikawa, Tomohiro
    Yamashita, Tomoko
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 314 - 324
  • [47] Determination of alprazolam by liquid chromatography-tandem mass spectrometry
    Svinarov, DA
    Kotzev, C
    Kassabova, LV
    CLINICA CHIMICA ACTA, 2005, 355 : S421 - S421
  • [48] Determination of stanozolol in hair using liquid chromatography-tandem mass spectrometry
    Xiang Ping
    Shen Min
    Shen Baohua
    Yan Hui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (04) : 469 - 472
  • [49] Determination of cyclosporine in saliva using liquid chromatography-tandem mass spectrometry
    Mendonza, A
    Gohh, R
    Akhlaghi, F
    THERAPEUTIC DRUG MONITORING, 2004, 26 (05) : 569 - 575
  • [50] Determination of protease inhibitors using liquid chromatography-tandem mass spectrometry
    Frerichs, VA
    DiFrancesco, R
    Morse, GD
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 787 (02): : 393 - 403