Determination of total and unbound ribociclib in human plasma and brain tumor tissues using liquid chromatography coupled with tandem mass spectrometry

被引:23
|
作者
Bao, Xun [1 ]
Wu, Jianmei [1 ]
Sanai, Nader [2 ]
Li, Jing [1 ]
机构
[1] Wayne State Univ, Karmanos Canc Inst, Detroit, MI 48201 USA
[2] St Josephs Hosp, Barrow Neurol Inst, Phoenix, AZ 85013 USA
关键词
Ribociclib; Liquid chromatography with tandem mass spectrometry (LC-MS/MS); Aqueous normal-phase liquid chromatography; Protein binding; Blood-brain barrier; Pharmacokinetics; NORMAL-PHASE CHROMATOGRAPHY; CDK4/6; INHIBITOR; CANCER; KINASE; PROTEINS; TARGETS; BINDING; LEE011;
D O I
10.1016/j.jpba.2019.01.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ribociclib is a selective, orally bioavailable inhibitor of cyclin-dependent kinase (CDK) 4/6, which has therapeutic potential for a variety of cancer types. This study was to develop and validate a liquid chromatography with tandem mass spectrometry (LC-MS/MS) method for determining total and unbound concentrations of ribociclib in human plasma and brain tumor tissue samples. Plasma and tumor homogenate samples were extracted using protein precipitation with acetonitrile. Unbound fraction in plasma or tumor homogenate was determined by equilibrium dialysis method. Chromatographic separation was achieved based on aqueous normal-phase chromatography mechanism on a Waters XBridge (TM) Amide column under isocratic elution with acetonitrile-ammonium formate (10 mM, pH 3) (75:25, v/v) at a flow rate of 0.8 mLimin. Ribociclib and the internal standard ([C-13(6)]ribociclib) were monitored at the mass transitions m/z, 435.3 > 367.2 and 441.3 > 373.2, respectively, using positive electrospray ionization mode. The lower limit of quantitation (LLOQ) was 0.5 nM of ribociclib in plasma. Linear calibration curve was established at the concentration range of 0.5-1000 nM in plasma. Intra- and inter-day precision and accuracy were within the generally accepted criteria for bioanalytical method. The developed method was successfully applied to determine the plasma pharmacokinetics and central nervous system penetration of ribociclib in patients with malignant primary brain cancer. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 50 条
  • [1] A liquid chromatography with tandem mass spectrometry method for quantitating total and unbound ceritinib in patient plasma and brain tumor
    Xun Bao
    Jianmei Wu
    Nader Sanai
    Jing Li
    JournalofPharmaceuticalAnalysis, 2018, 8 (01) : 20 - 26
  • [2] A liquid chromatography with tandem mass spectrometry method for quantitating total and unbound ceritinib in patient plasma and brain tumor
    Bao, Xun
    Wu, Jianmei
    Sanai, Nader
    Li, Jing
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2018, 8 (01) : 20 - 26
  • [3] DETERMINATION OF TOTAL AND UNBOUND CONCENTRATIONS OF VALPROIC ACID IN HUMAN PLASMA BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Fernandez-Campos, F.
    Calpena, A.
    Soy, D.
    Colom, H.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (09) : 1171 - 1183
  • [4] Development and validation of a liquid chromatography coupled with tandem mass spectrometry method for determining total and unbound pamiparib in human plasma and brain tumors
    Jiang, Jun
    Bao, Xun
    Yue, Yang
    Schiff, David
    Bindra, Ranjit
    Li, Jing
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (12)
  • [5] Determination of methacycline in human plasma by liquid chromatography coupled to tandem mass spectrometry
    Chen, XY
    Ren, S
    Meng, F
    Zhang, YF
    Zhong, DF
    ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) : 15 - 20
  • [6] Determination of total and unbound concentrations of lopinavir in plasma using liquid chromatography-tandem mass spectrometry and ultrafiltration methods
    Illamola, S. M.
    Labat, L.
    Benaboud, S.
    Tubiana, R.
    Warszawski, J.
    Treluyer, J. M.
    Hirt, D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 965 : 216 - 223
  • [7] Determination of misoprostol acid in human plasma by liquid chromatography coupled to tandem mass spectrometry
    Zou, Yu
    Chen, Xiaoyan
    Song, Bo
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 122 - 127
  • [8] Enantiomeric determination of amlodipine in human plasma by liquid chromatography coupled to tandem mass spectrometry
    Streel, B
    Lainé, C
    Zimmer, C
    Sibenaler, R
    Ceccato, A
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2002, 54 (1-3): : 357 - 368
  • [9] Quantitative determination of icotinib in human plasma and urine using liquid chromatography coupled to tandem mass spectrometry
    Liu, Dongyang
    Jiang, Ji
    Hu, Pei
    Tan, Fenlai
    Wang, Yingxiang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (30): : 3781 - 3786
  • [10] Specific method for determination of gefitinib in human plasma, mouse plasma and tissues using high performance liquid chromatography coupled to tandem mass spectrometry
    Zhao, M
    Hartke, C
    Jimeno, A
    Li, J
    He, P
    Zabelina, Y
    Hidalgo, M
    Baker, SD
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (01): : 73 - 80