Determination of total and unbound concentrations of lopinavir in plasma using liquid chromatography-tandem mass spectrometry and ultrafiltration methods

被引:17
|
作者
Illamola, S. M. [1 ]
Labat, L. [2 ]
Benaboud, S. [2 ,3 ]
Tubiana, R. [4 ,5 ]
Warszawski, J. [6 ,7 ,8 ]
Treluyer, J. M. [1 ,2 ,3 ,9 ]
Hirt, D. [2 ,3 ]
机构
[1] Hop Tarnier, AP HP, Unite Rech Clin, F-75006 Paris, France
[2] Grp Hosp Pitie Salpetriere, AP HP, Paris Ctr, Serv Pharmacol Clin, F-75634 Paris, France
[3] Univ Paris 05, Sorbonne Paris Cite, EAU08, Paris, France
[4] Hop La Pitie Salpetriere, AP HP, Serv Malad Infect, Paris, France
[5] UPMC Paris 06, Univ Paris 04, UMR Pierre Louis Inst Epidemiol & Publ Hlth S 113, F-75013 Paris, France
[6] INSERM, Ctr Res Epidemiol & Populat Hlth, Equipe VIH & IST, U1018, F-94275 Le Kremlin Bicetre, France
[7] Hop Bicetre, AP HP, Serv Epidemiol & Sante Publ, Le Kremlin Bicetre, France
[8] Univ Paris 11, UMRS 1018, Le Kremlin Bicetre, France
[9] INSERM, CIC 0901, Paris, France
关键词
Lopinavir; Unbound fraction; Ultrafiltration; Nonspecific binding; UPLC-MS/MS; HIV-PROTEASE INHIBITORS; REVERSE-TRANSCRIPTASE INHIBITORS; BLOOD MONONUCLEAR-CELLS; ANTIRETROVIRAL DRUGS; SIMULTANEOUS QUANTIFICATION; QUANTITATIVE-ANALYSIS; NONSPECIFIC-BINDING; RITONAVIR; VALIDATION; MS/MS;
D O I
10.1016/j.jchromb.2014.06.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Lopinavir is an HIV protease inhibitor with high protein binding (98-99%) in human plasma. This study was designed to develop an ultrafiltration method to measure the unbound concentrations of lopinavir overcoming the non-specific binding issue. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of total concentrations of lopinavir in plasma was developed and validated, and an adaptation was also optimized and validated for the determination of unbound concentrations. The chromatographic separation was performed with a C-18 column (100 mm x 2.1 mm i.d., 5 mu m particle size) using a mobile phase containing deionized water with formic acid, and acetonitrile, with gradient elution at a flow-rate of 350 mu Lmin(-1). Identification of the compounds was performed by multiple reaction monitoring, using electrospray ionization in positive ion mode. The method was validated over a clinical range of 0.01-1 mu g/mL for human plasma ultrafiltrate and 0.1-15 mu g/mL in human plasma. The inter and intra-assay accuracies and precisions were between 0.23% and 11.37% for total lopinavir concentrations, and between 3.50% and 13.30% for plasma ultrafiltrate (unbound concentration). The ultrafiltration method described allows an accurate separation of the unbound fraction of lopinavir, circumscribing the loss of drug by nonspecific binding (NSB), and the validated LC-MS/MS methodology proposed is suitable for the determination of total and unbound concentrations of lopinavir in clinical practice. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 50 条
  • [31] Simple and Sensitive Determination of Nisoldipine in Plasma Using Liquid Chromatography-Tandem Mass Spectrometry
    Wonku Kang
    Analytical Sciences, 2006, 22 : 1597 - 1599
  • [32] Determination of albendazole sulfoxide in human plasma by using liquid chromatography-tandem mass spectrometry
    Saraner, Nihal
    Ozkan, Guler Yagmur
    Guney, Berrak
    Alkan, Erkin
    Burul-Bozkurt, Nihan
    Saglam, Onursal
    Fikirdesici, Ezgi
    Yaldirim, Mevlut
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1022 : 1 - 5
  • [33] Quantitative determination of sarsasapogenin in rat plasma using liquid chromatography-tandem mass spectrometry
    Yang, Bo
    Liu, Zhirui
    Hu, Jing
    Lai, Xiaodan
    Xia, Peiyuan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1022 : 213 - 219
  • [34] Simple and sensitive determination of nisoldipine in plasma using liquid chromatography-tandem mass spectrometry
    Kang, Wonku
    ANALYTICAL SCIENCES, 2006, 22 (12) : 1597 - 1599
  • [35] Determination of Liraglutide in Rat Plasma Using Selective Liquid Chromatography-Tandem Mass Spectrometry
    Kim, Younah
    Jo, Hyoje
    Lee, Yelim
    Kang, Soo Yeon
    Lee, Sangkyu
    MASS SPECTROMETRY LETTERS, 2024, 14 (04) : 141 - 146
  • [36] Simultaneous determination of β-blockers in human plasma using liquid chromatography-tandem mass spectrometry
    Umezawa, Hironobu
    Lee, Xiao-Pen
    Arima, Yoshiko
    Hasegawa, Chika
    Izawa, Hikaru
    Kumazawa, Takeshi
    Sato, Keizo
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 702 - 711
  • [37] Establishment and application of a rapid method for the determination of both total and unbound anlotinib concentrations by high-performance liquid chromatography-tandem mass spectrometry
    Zhang, Min
    Song, Haichi
    Yuan, Zhongzhen
    Tang, Tiantian
    Li, Qiaoqiao
    Zeng, Jin
    Li, Lixian
    Chen, Wanyi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2025, 1256
  • [38] Determination of doxepin and desmethyldoxepin in human plasma using liquid chromatography-tandem mass spectrometry
    Badenhorst, D
    Sutherland, FCW
    de Jager, AD
    Scanes, T
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (01): : 91 - 98
  • [39] Determination of free vitamin D in serum by ultrafiltration with liquid chromatography-tandem mass spectrometry
    Wang, D.
    CLINICA CHIMICA ACTA, 2022, 530 : S357 - S357
  • [40] Simultaneous determination of linezolid and voriconazole serum concentrations using liquid chromatography-tandem mass spectrometry
    Lu, Qiuya
    He, Xiaoshuang
    Fang, Jie
    Shi, Kaifeng
    Hu, Fengmei
    Bian, Xiaolan
    Wang, Xuefeng
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 212