Advances in photoplethysmography: beyond arterial oxygen saturation

被引:0
|
作者
Bartels, Karsten [1 ,2 ]
Thiele, Robert H. [3 ,4 ,5 ,6 ]
机构
[1] Univ Colorado Denver, Dept Anesthesiol, Aurora, CO USA
[2] Univ Colorado Denver, Dept Surg, Aurora, CO USA
[3] Univ Virginia, Sch Med, Dept Anesthesiol, Div Cardiac, Charlottesville, VA 22908 USA
[4] Univ Virginia, Sch Med, Dept Anesthesiol, Div Thorac, Charlottesville, VA 22908 USA
[5] Univ Virginia, Sch Med, Dept Anesthesiol, Div Crit Care Anesthesiol, Charlottesville, VA 22908 USA
[6] Univ Virginia, Sch Med, Dept Biomed Engn, Charlottesville, VA 22908 USA
关键词
PLETH VARIABILITY INDEX; PREDICT FLUID RESPONSIVENESS; WAVE-FORM AMPLITUDE; MECHANICALLY VENTILATED PATIENTS; CONTINUOUS CARDIAC-OUTPUT; SYSTOLIC BLOOD-PRESSURE; RANDOMIZED CONTROLLED-TRIAL; CRITICALLY-ILL PATIENTS; STROKE VOLUME VARIATION; PULSE TRANSIT-TIME;
D O I
10.1007/s12630-015-0458-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose Photoplethysmography permits continuous measurement of heart rate and peripheral oxygen saturation and has been widely used to inform clinical decisions. Recently, a myriad of noninvasive hemodynamic monitoring devices using this same technology have been increasingly available. This narrative review aims to summarize the principles that form the basis for the function of these devices as well as to comment on trials evaluating their accuracy and clinical application. Principal findings Advanced monitoring devices extend photoplethysmography technology beyond measuring oxygen concentration and heart rate. Quantification of respiratory variation of the photoplethysmographic waveform reflects respiratory variation of the arterial pressure waveform and can be used to gauge volume responsiveness. Both the volume-clamp and physiocal techniques are extensions of conventional photoplethysmography and permit continuous measurement of finger arterial blood pressure. Finger arterial pressure waveforms can subsequently inform estimations of cardiac output. Conclusions Although respiratory variations of the plethysmographic waveform correlate only modestly with the arterial blood pressure waveform, fluid responsiveness can be relatively consistently assessed using both approaches. Continuous blood pressure measurements obtained using the volume-clamp technique may be as accurate as conventional brachial noninvasive blood pressure measurements. Most importantly, clinical comparative effectiveness studies are still needed in order to determine if these technologies can be translated into improvement of relevant patient outcomes.
引用
收藏
页码:1313 / 1328
页数:16
相关论文
共 50 条
  • [1] Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
    Shelley, Kirk H.
    ANESTHESIA AND ANALGESIA, 2007, 105 : S31 - S36
  • [2] AN ACCURATE CALIBRATION METHOD FOR THE MEASUREMENT OF ARTERIAL OXYGEN SATURATION USING PHOTOPLETHYSMOGRAPHY
    Wang, Yongjian
    Pu, Lina
    Wu, Dan
    Lin, Wan-Hua
    Wong, Kelvin Kian Loong
    Zhang, Heye
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (01)
  • [3] Advances in photoplethysmography: beyond arterial oxygen saturation [Progrès de la photopléthysmographie: au-delà de la saturation artérielle en oxygène]
    Bartels K.
    Thiele R.H.
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2015, 62 (12): : 1313 - 1328
  • [4] Evaluation of arterial oxygen saturation using RGB camera-based remote photoplethysmography
    Nishidate, Izumi
    Nakano, Kazuya
    McDuff, Daniel
    Niizeki, Kyuichi
    Aizu, Yoshihisa
    Haneishi, Hideaki
    OPTICAL DIAGNOSTICS AND SENSING XVIII: TOWARD POINT-OF-CARE DIAGNOSTICS, 2018, 10501
  • [5] Continuous measurement of oxygen saturation level using Photoplethysmography signal
    Azmal, Gazi Maruf
    Al-Jumaily, Adel
    Al-Jaafreh, Moha'med
    2006 INTERNATIONAL CONFERENCE ON BIOMEDICAL AND PHARMACEUTICAL ENGINEERING, VOLS 1 AND 2, 2006, : 501 - +
  • [6] Remote Photoplethysmography (rPPG) for Contactless Blood Oxygen Saturation Monitoring
    Kannaa, Yaythish G. S.
    Bhattacharya, Sayantani
    Aishwarya, N.
    10TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTING AND COMMUNICATION TECHNOLOGIES, CONECCT 2024, 2024,
  • [7] Arterial Oxygen Saturation: A Vital Sign?
    Singhal, A.
    Prafull, K.
    Daulatabad, V. S.
    John, N. A.
    John, J.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (11) : 1591 - 1594
  • [8] Arterial oxygen saturation decreases with age
    Tsai, P
    Harris, A
    Kagemann, L
    Kresovsky, S
    Dinn, R
    Siesky, B
    McCranor, L
    Catoira, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U968 - U968
  • [9] Arterial oxygen saturation in cirrhosis of the liver
    Darling, RC
    ANNALS OF INTERNAL MEDICINE, 1940, 14 (05) : 898 - 902
  • [10] The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources
    Mou, Ling
    Gong, Quan
    Wei, Wei
    Gao, Bo
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (03) : 365 - 370