Continuous measurement of oxygen saturation level using Photoplethysmography signal

被引:0
|
作者
Azmal, Gazi Maruf [1 ]
Al-Jumaily, Adel [1 ]
Al-Jaafreh, Moha'med [1 ]
机构
[1] Univ Technol Sydney, Fac Engn, Sydney, NSW 2007, Australia
关键词
oxygen saturation level; photoplethysmography; pulse oximetry;
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Measuring Oxygen Saturation Level is an important part in monitoring patient's health condition. This is commonly monitored by a pulse oximeter, which has been widely adopted around the world as a standard measure during anesthesia, neonatal care and post-operative recovery. However, measuring Oxygen level continuously is very important for aged people, pregnant women and in many other critical situations. This paper considers the problem of measuring Oxygen saturation level continuously, a method to measure Oxygen Level using Photoplethysmography (PPG) signal has been presented. A prototype transducer has been built to measure the PPG. The transducer needs to be in contact to the subject's finger. Developed algorithm is presented that achieved accurate oxygen level and an experiment was also carried out on subjects' finger.
引用
收藏
页码:501 / +
页数:2
相关论文
共 50 条
  • [1] AN ACCURATE CALIBRATION METHOD FOR THE MEASUREMENT OF ARTERIAL OXYGEN SATURATION USING PHOTOPLETHYSMOGRAPHY
    Wang, Yongjian
    Pu, Lina
    Wu, Dan
    Lin, Wan-Hua
    Wong, Kelvin Kian Loong
    Zhang, Heye
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (01)
  • [2] The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources
    Mou, Ling
    Gong, Quan
    Wei, Wei
    Gao, Bo
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2013, 27 (03) : 365 - 370
  • [3] The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources
    Ling Mou
    Quan Gong
    Wei Wei
    Bo Gao
    Journal of Clinical Monitoring and Computing, 2013, 27 : 365 - 370
  • [4] Development of a Photoplethysmography Signal Processing Method for Oxygen Measurement Concentration
    Ahmed, Waiz
    Khan, Sheroz
    Sidek, Khairul Azami
    2014 INTERNATIONAL CONFERENCE ON COMPUTER AND COMMUNICATION ENGINEERING (ICCCE), 2014, : 40 - 43
  • [5] Advances in photoplethysmography: beyond arterial oxygen saturation
    Bartels, Karsten
    Thiele, Robert H.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (12): : 1313 - 1328
  • [6] CONTINUOUS INTRAPARTUM MEASUREMENT OF FETAL OXYGEN-SATURATION
    JOHNSON, N
    LILFORD, RJ
    LANCET, 1988, 2 (8609): : 517 - 517
  • [7] CONTINUOUS INTRAPARTUM MEASUREMENT OF FETAL OXYGEN-SATURATION
    PEAT, S
    BOOKER, M
    LANIGAN, C
    PONTE, J
    LANCET, 1988, 2 (8604): : 213 - 213
  • [8] THE CONTINUOUS MEASUREMENT OF MIXED VENOUS OXYGEN-SATURATION
    HARPIN, RP
    DOWNER, JP
    CHEST, 1985, 87 (06) : 845 - 845
  • [9] A Textile Sleeve for Monitoring Oxygen Saturation Using Multichannel Optical Fibre Photoplethysmography
    Ballaji, Hattan K.
    Correia, Ricardo
    Korposh, Serhiy
    Hayes-Gill, Barrie R.
    Hernandez, Francisco U.
    Salisbury, Byron
    Morgan, Stephen P.
    SENSORS, 2020, 20 (22) : 1 - 29
  • [10] CONTINUOUS INVIVO MEASUREMENT OF ARTERIAL OXYGEN-SATURATION BY OXIMETRY
    FLICK, MR
    BLOCK, AJ
    HEART & LUNG, 1977, 6 (06): : 990 - 993