Continuous measurement of oxygen saturation level using Photoplethysmography signal

被引:0
|
作者
Azmal, Gazi Maruf [1 ]
Al-Jumaily, Adel [1 ]
Al-Jaafreh, Moha'med [1 ]
机构
[1] Univ Technol Sydney, Fac Engn, Sydney, NSW 2007, Australia
关键词
oxygen saturation level; photoplethysmography; pulse oximetry;
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Measuring Oxygen Saturation Level is an important part in monitoring patient's health condition. This is commonly monitored by a pulse oximeter, which has been widely adopted around the world as a standard measure during anesthesia, neonatal care and post-operative recovery. However, measuring Oxygen level continuously is very important for aged people, pregnant women and in many other critical situations. This paper considers the problem of measuring Oxygen saturation level continuously, a method to measure Oxygen Level using Photoplethysmography (PPG) signal has been presented. A prototype transducer has been built to measure the PPG. The transducer needs to be in contact to the subject's finger. Developed algorithm is presented that achieved accurate oxygen level and an experiment was also carried out on subjects' finger.
引用
收藏
页码:501 / +
页数:2
相关论文
共 50 条
  • [21] Continuous blood pressure measurement based on photoplethysmography
    Chen Yi
    Cheng Jian
    Ji Wenqiang
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 1656 - 1663
  • [22] ROSE-Net: Leveraging remote photoplethysmography to estimate oxygen saturation using deep learning
    Chowdhury, Moajjem Hossain
    Reaz, Mamun Bin Ibne
    Ali, Sawal Hamid Md
    Khan, Muhammad Salman
    Chowdhury, Muhammad E. H.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 100
  • [23] Peripheral venous blood oxygen saturation can be non-invasively estimated using photoplethysmography
    Khan, Musabbir
    Pretty, Christopher G.
    Amies, Alexander C.
    Elliott, Rodney B.
    Suhaimi, Fatanah M.
    Shaw, Geoffrey M.
    Chase, J. Geoffrey
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6405 - 6408
  • [24] Peripheral Oxygen Saturation Measurement Using an RGB Camera
    Wu, Bing-Jhang
    Wu, Bing-Fei
    Dong, You-Cheng
    Lin, Hsiang-Chun
    Li, Ping-Hung
    IEEE SENSORS JOURNAL, 2023, 23 (21) : 26551 - 26563
  • [25] Biometric Identification Using Photoplethysmography Signal
    Al-Sidani, Aya
    Ibrahim, Bilal
    Cherry, Ali
    Hajj-Hassan, Mohamad
    2018 THIRD INTERNATIONAL CONFERENCE ON ELECTRICAL AND BIOMEDICAL ENGINEERING, CLEAN ENERGY AND GREEN COMPUTING (EBECEGC), 2018, : 12 - 15
  • [26] Drowsiness Detection using Photoplethysmography Signal
    Kurian, Deepu
    Joseph, Johnson P. L.
    Radhakrishnan, Krishnaja
    Balakrishnan, Arun A.
    2014 FOURTH INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING AND COMMUNICATIONS (ICACC), 2014, : 73 - 76
  • [27] Validation of a spectroscopic sensor for the continuous, noninvasive measurement of muscle oxygen saturation and pH
    Ellerby, G. E. C.
    Smith, C. P.
    Zou, F.
    Scott, P.
    Soller, B. R.
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (08) : 859 - 871
  • [28] Accurate Detection of Heart Rate and Blood Oxygen Saturation in Reflective Photoplethysmography
    Krizea, Maria
    Gialelis, John
    Kladas, Anastasios
    Theodorou, Gerasimos
    Protopsaltis, Grigoris
    Koubias, Stavros
    2020 IEEE INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND INFORMATION TECHNOLOGY (ISSPIT 2020), 2020,
  • [29] Determination of Oxygen Saturation Based on Distorted Photoplethysmography Signals by Scaling Method
    Naguszewski, Adam
    Weremczuk, Jerzy
    2018 XV INTERNATIONAL SCIENTIFIC CONFERENCE ON OPTOELECTRONIC AND ELECTRONIC SENSORS (COE), 2018,
  • [30] Continuous central venous oxygen saturation (ScvO(2)) measurement using a fibre optic catheter in newborn infants
    vanderHoeven, MAHBM
    Maertzdorf, WJ
    Blanco, CE
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1996, 74 (03): : F177 - F181